This comprehensive manual is essential for the safe selection, installation, and maintenance of professional-grade LED lighting systems. It provides detailed guidelines covering safe mounting procedures, wiring protocols, electrical precautions, and technical specifications for various industrial LED modules. Ideal for electricians, facility managers, and automation technicians, this guide ensures optimal performance while adhering to rigorous safety standards for specialized commercial environments.
Page 1 Text Content
■Specifications
PRECAUTIONS FOR SAFE USE
Item Model FLV-BR6022W FLV-BR8532W FLV-BR11222W FLV-BR14030W FLV-BR15020W FLV-BR21222W FLV-BR21230W FLV-BR38037W FLV-BR48031W
Please observe the following precautions for safe use of the products.
1. Installation Environment FLV-BR6022R FLV-BR8532R FLV-BR11222R FLV-BR14030R FLV-BR15020R FLV-BR21222R FLV-BR21230R FLV-BR38037R FLV-BR48031R
• Do not use the product in environments where it can be exposed to FLV-BR6022B FLV-BR8532B FLV-BR11222B FLV-BR14030B FLV-BR15020B FLV-BR21222B FLV-BR21230B FLV-BR38037B FLV-BR48031B inflammable/explosive gas.
Applicable Controllers FLV-TCC4□/-TCC1□/-TCC3HB□、FLV-ATC□1024-□
• To secure the safety of operation and maintenance, do not install the product close to high-voltage devices and power devices. Lighting color (peak wavelength) W:White、R:Red(Typ.635nm)、B:Blue(Typ.460nm)
Model FLV-BR□ • Tighten the screws with the specified torque in this document.
Light source LED
2. Power Supply and Wiring
• For details on power supply and wiring, refer to PRECAUTIONS FOR SAFE LED Safety W, B: Risk Group 2、R: Risk Group 1 (IEC62471)
USE on the INSTRUCTION SHEET of the dedicated controller (FLV-TCC4□ Electricity White 1.4W 3.5W 4.2W 6.1W 5.5W 8.7W 8.8W 15.9W 21.9W
Bar Lighting
/-TCC1□/-TCC3HB□, FLV-ATC□1024-□).
Red 1.3W 3.1W 2.6W 4.8W 3.1W 5.0W 7.0W 11.3W 18.0W
• When connecting or disconnecting the lighting connector, be sure to turn off the power of the unit. Not doing so may result in malfunction. Blue 1.4W 3.5W 4.2W 6.1W 5.5W 8.7W 8.8W 15.9W 21.9W
INSTRUCTION SHEET • The temperature may reach 70°C while power is being supplied under thermally
Insulation Resistance 20 MΩ (250VDC)
neutral environment. Do not touch the product directly. Be sure
to wear heat-resistant gloves. Ambient Temperature Operating: 0 to +50℃, Storage: -15 to +60℃ (with no icing or condensation)
Thank you for selecting OMRON product. This sheet
• High-Voltage lines and power lines must be wired separately from this product.
Ambient Humidity Operating and storage: 35% to 85% (with no condensation)
primarily describes precautions required in installing and Wiring them together or placing them in the same duct may cause induction,
resulting in malfunction or damage. Degree of Protection IP20(IEC60529)
operating the product.
• Take sufficient safety measures such as fail-safe circuit to use the product. Vibration Resistance(destructive) 10 to 150 Hz, (0.7mm double amplitude) 80 min. each in X, Y, and Z directions
Before operating the product, read the sheet thoroughly 3. Others
Shock Resistance (destructive) 150 m/s2 3 times each in 6 directions(up/down, left/right, forward/backward)
to acquire sufficient knowledge of the product. For your • Do not use in safety circuits for atomic energy or that are critical for human life. • Do not attempt to disassemble, deform by pressure, incinerate, repair, or modify this product. Materials Case:Aluminum
convenience, keep the sheet at your disposal.
• When disposing of the product, treat as industrial waste.
Weight Approx.60g Approx.130g Approx.100g Approx.140g Approx.120g Approx.140g Approx.220g Approx.430g Approx.460g
• Be sure to connect a dedicated lighting controller (FLV-TCC4□/-TCC1□
TRACEABILITY INFORMATION:
/-TCC3HB□, FLV-ATC□1024-□).Use of other devices may result in fire, Accessories Instruction sheet (this sheet)
Representative in EU: Manufacturer:
Omron Europe B.V. Omron Corporation, explosion, malfunction or failure.
Wegalaan 67-69 Shiokoji Horikawa, Shimogyo-ku, • If you notice an abnormal condition such as a strange odor, extreme 2132 JD Hoofddorp, Kyoto 600-8530 JAPAN heating of the unit, or smoke, immediately stop using the product, turn off the The Netherlands Ayabe Factory
3-2 Narutani, Nakayama-cho, power, and consult your dealer. Ayabe-shi, Kyoto 623-0105 JAPAN • Do not drop or impose excessive vibration or shock on the product. It may cause breakdown of the product.
The following notice applies only to products that carry the CE mark: • Ensure that all components which have locking mechanisms are locked before Notice: using the product. This is a class A product. In residential areas it may cause radio • Make sure not to drop the product when unpacking or moving it.
■Connection with Lighting Controller
interference, in which case the user may be required to take adequate
4. Regulations and standards
measures to reduce interference.
This lighting complied with the EN standard (EN61326) with a EMC
●Mounting
directive (No.2004/108/EC).
Align the positions of "the tab of the connector at the lighting
2280618-6D cable" and "protrusion of the lighting connector at the Lighting
© OMRON Corporation 2013 All Rights Reserved. Controller", and then insert it until it clicks.
PRECAUTIONS FOR CORRECT USE Observe the following to prevent failure, malfunctioning, and adverse effects on Before mounting After mounting performance and the device. 1. Installation site
Lighting controller side
Do not install in the following locations: PRECAUTIONS ON SAFETY • Locations where the ambient temperature exceeds the rated temperature range. • Locations subject to sudden temperature changes (where condensation will form). ● Meanings of Signal Words • Locations where the relative humidity is below or above 35 to 85% RH. • Locations where there are corrosive or flammable gases.
Indicates a potentially hazardous situation which, if not
• Locations where there is dust, salt, or iron powder.
avoided, will result in minor or moderate injury, or may
WARNING • Locations where the device will be subject to direct vibration or shock.
result in serious injury or death. Additionally, there may
• Locations where there is strong scattered light (laser light, arc welding light,
be significant property damage. Lighting side
ultraviolet light, etc.) Indicates a potentially hazardous situation which, if not • Locations exposed to direct sunlight or next to a heater. avoided, may result in minor or moderate injury or in • Locations where there is splashing or spraying of water, oil, or chemicals.
CAUTION
property damage. • Locations where there is a strong electrical or magnetic field. 2.Maintenance ● Alert Statements in This Sheet • Do not install the product close to high-voltage devices and/or power devices in ●Removing order to secure the safety of operations and maintenance.
Hold "the tab of the connector at the lighting cable" in the arrow
WARNING • When this product and a cable are attached or removed, be sure to turn OFF the
power of the Controller first before operation. (←) direction and pull it straight.
This product is not designed or rated for ensuring safety of • Never use paint thinner, benzen, acetone, or kerosene to clean the product.Wipe 【Note】 persons either directly or indirectly. Do not use it for such the contamination with a soft cloth included a small amount of alcohol.
Do not pull out with excessive force without pressing the tab.
purposes. 3. Power and cable connections • When using a commercially available switching regulator, make sure that the
Do not disassemble the product. Doing so may cause Frame ground terminal is grounded. electric shock due to the high voltage portion. Burn also • If there are surges on your power line, connect a surge absorber as appropriate Before removing After removing may result due to high temperature. Do not attempt to for your conditions of use. disassemble, deform by pressure, incinerate, repair, or • Before turning on the power after the wiring is completed, verify that the power is Lighting controller side modify this product. correct, that there are no incorrect connections such as a shorted load circuit, and
that the load current is suitable. Incorrect wiring may cause damage and failures.
Looking into the LED light continuously may cause visual
• Use the product with the specified voltage. Applying a voltage or AC voltage
impairment. Do not look directly into the LED light.
that exceed the rating may result in burning or explosion of circuit components. • For cable extension between the lighting and lighting controller, use an optional extension cable (FLV-XC□/-XC□R) or branch cable (FLV-XC□S2). Only
CAUTION one extension cable and branch cable can be used.
Lighting side
• The bending radius at cable wiring must be at least 20 mm.
Do not use it exceeding the rated voltage.
4.Warming Up
There is a possibility of failure and fire.
After turning on the power supply, allow the controller to stand for at least 30 minutes before use. As the circuits are unstable immediately after power on,
Do not connect amplifier units to AC power supply.
brightness may gradually change.
Risk of explosion.
5. Lighting electricity Beware of danger of burns. Lighting electricity for lighting equipment to be connected to the Lighting Do not touch the case while the LED is ON or immediately Controller is limited. Be sure to check the lighting electricity written on the plate after the power is turned OFF, since it is extremely hot. of the product, label of the packaging box or this manual to connect a lighting within the specified value. 6. Static Electricity LEDs are easily damaged by static electricity. A grounded wrist strap should thus be used when installing or conducting maintenance on the Diffusion Board.
Page Summary Contents For OMRON Image Processing System FZ5 Series FLV-BR[]Bar Lighting Instruction Sheet
Manual Details
| Brand | Image |
|---|---|
| Pages | 2 |
| File Size | 538.67 KB |
| Published | June 03, 2026 |
Enter the captcha to get the download link:
Frequently Asked Questions
What precautions must be taken regarding the installation environment?
Do not use the product in environments with flammable/explosive gas, and keep it away from high-voltage devices.
How should I power the unit or what must I do when connecting cables?
Be sure to turn off the unit's power before connecting or disconnecting any lighting connector.
Can this product withstand physical impact like dropping or vibration?
It is not recommended to drop, impose excessive vibration, or shake the product as it may cause breakdown.
What are the operating temperature and humidity limits?
The ambient operating range is 0 to +50°C, with an acceptable storage range of -15 to +60°C (no icing/condensation). Humidity should be 35% to 85%.