Designed for industrial automation professionals, this manual provides critical safety guidelines and specifications for OMRON's series of LED lighting components. It details essential precautionary measures covering safe installation environments, proper wiring practices (including high voltage separation), environmental limitations (temperature/humidity), vibration handling, and system integration requirements. Use this guide to ensure the secure, reliable, and compliant deployment of the lighting system into professional industrial settings.

📄 Preview PAGE OF 2

Page 1 Text Content

■Specifications

PRECAUTIONS FOR SAFE USE

Item Model FLV-FB5050W FLV-FB7070W FLV-FB9090W FLV-FB130130W FLV-FB200200W

Please observe the following precautions for safe use of the products.

1. Installation Environment FLV-FB5050R FLV-FB7070R FLV-FB9090R FLV-FB130130R FLV-FB200200R

• Do not use the product in environments where it can be exposed to

FLV-FB5050B FLV-FB7070B FLV-FB9090B FLV-FB130130B FLV-FB200200B

inflammable/explosive gas.

• To secure the safety of operation and maintenance, do not install the product Applicable Controllers FLV-TCC4□/-TCC1□/-TCC3HB□、FLV-ATC□1024-□

close to high-voltage devices and power devices. Lighting color (peak wavelength)

W:White、R:Red(Typ.625nm)、B:Blue(Typ.460nm)

• Tighten the screws with the specified torque in this document.

Model FLV-FB□ Light source LED

2. Power Supply and Wiring • For details on power supply and wiring, refer to PRECAUTIONS FOR SAFE LED Safety Risk Group 1(IEC62471) USE on the INSTRUCTION SHEET of the dedicated controller (FLV-TCC4□

/-TCC1□/-TCC3HB□, FLV-ATC□1024-□). Electricity White 1.9W 1.9W 3.7W 5.5W 7.3W

Edge Type Lighting

• When connecting or disconnecting the lighting connector, be sure to turn off the White 1.0W 1.4W 1.9W 3.7W 5.5W power of the unit. Not doing so may result in malfunction.

Blue 1.9W 1.9W 3.7W 5.5W 7.3W

• The temperature may reach 70°C while power is being supplied under

INSTRUCTION SHEET thermally neutral environment. Do not touch the product directly. Be sure Insulation Resistance 20 MΩ (250VDC)

to wear heat-resistant gloves.

Ambient Temperature Operating: 0 to +50℃, Storage: -15 to +60℃ (with no icing or condensation)

• High-Voltage lines and power lines must be wired separately from this product.

Thank you for selecting OMRON product. This sheet Wiring them together or placing them in the same duct may cause induction, Ambient Humidity Operating and storage: 35% to 85% (with no condensation)

primarily describes precautions required in installing and resulting in malfunction or damage.

Degree of Protection IP20(IEC60529)

• Take sufficient safety measures such as fail-safe circuit to use the product.

operating the product.

3. Others Vibration Resistance(destructive) 10 to 150 Hz, (0.7mm double amplitude) 80 min. each in X, Y, and Z directions

Before operating the product, read the sheet thoroughly • Do not use in safety circuits for atomic energy or that are critical for human life.

Shock Resistance (destructive) 150 m/s2 3 times each in 6 directions(up/down, left/right, forward/backward)

• Do not attempt to disassemble, deform by pressure, incinerate, repair, or modify

to acquire sufficient knowledge of the product. For your

this product. Materials Case:Aluminum,PMMA

convenience, keep the sheet at your disposal. • When disposing of the product, treat as industrial waste.

Weight Approx.75g Approx.85g Approx.155g Approx.230g Approx.710g

• Be sure to connect a dedicated lighting controller (FLV-TCC4□/-TCC1□

TRACEABILITY INFORMATION: /-TCC3HB□, FLV-ATC□1024-□).Use of other devices may result in fire, Accessories Instruction sheet (this sheet)

Representative in EU: Manufacturer: explosion, malfunction or failure. Omron Europe B.V. Omron Corporation,

• If you notice an abnormal condition such as a strange odor, extreme

Wegalaan 67-69 Shiokoji Horikawa, Shimogyo-ku,

2132 JD Hoofddorp, Kyoto 600-8530 JAPAN heating of the unit, or smoke, immediately stop using the product, turn off the The Netherlands Ayabe Factory power, and consult your dealer.

3-2 Narutani, Nakayama-cho, • Do not drop or impose excessive vibration or shock on the product. ■Connection with lighting controller Ayabe-shi, Kyoto 623-0105 JAPAN It may cause breakdown of the product.

• Ensure that all components which have locking mechanisms are locked before

The following notice applies only to products that carry the CE mark: ●Mounting

using the product.

Notice: Align the positions of "the tab of the connector at the lighting

• Make sure not to drop the product when unpacking or moving it.

This is a class A product. In residential areas it may cause radio

4. Regulations and standards cable" and "protrusion of the lighting connector at the lighting

interference, in which case the user may be required to take adequate

measures to reduce interference. This lighting complied with the EN standard (EN61326) with a EMC directive

controller", and then insert it until it clicks.

(No.2004/108/EC).

Before mounting After mounting

PRECAUTIONS FOR CORRECT USE

© OMRON Corporation 2013 All Rights Reserved. Lighting controller side

Observe the following to prevent failure, malfunctioning, and adverse effects on performance and the device. 1. Installation site Do not install in the following locations: • Locations where the ambient temperature exceeds the rated temperature range. PRECAUTIONS ON SAFETY • Locations subject to sudden temperature changes (where condensation will form). • Locations where the relative humidity is below or above 35 to 85% RH. • Locations where there are corrosive or flammable gases.

● Meanings of Signal Words • Locations where there is dust, salt, or iron powder. Lighting side

• Locations where the device will be subject to direct vibration or shock.

Indicates a potentially hazardous situation which, if • Locations where there is strong scattered light (laser light, arc welding light, not avoided, will result in minor or moderate injury, ultraviolet light, etc.)

WARNING

or may result in serious injury or death. Additionally, • Locations exposed to direct sunlight or next to a heater. there may be significant property damage. • Locations where there is splashing or spraying of water, oil, or chemicals. ●Removing

• Locations where there is a strong electrical or magnetic field. Hold "the tab of the connector at the lighting cable" in the arrow

Indicates a potentially hazardous situation which, if 2. Maintenance

CAUTION not avoided, may result in minor or moderate injury (←) direction and pull it straight.

• Do not install the product close to high-voltage devices and/or power devices

or in property damage. in order to secure the safety of operations and maintenance. 【Note】

• When this product and a cable are attached or removed, be sure to turn OFF

Do not pull out with excessive force without pressing the tab.

the power of the Controller first before operation. ● Alert Statements in This Sheet • Never use paint thinner, benzen, acetone, or kerosene to clean the product.Wipe the contamination with a soft cloth included a small amount of alcohol. 3. Power and cable connections Before removing After removing

WARNING

• When using a commercially available switching regulator, make sure that the Frame ground terminal is grounded. Lighting Controller side

This product is not designed or rated for ensuring safety

• If there are surges on your power line, connect a surge absorber as

of persons either directly or indirectly. Do not use it for

appropriate for your conditions of use.

such purposes.

• Before turning on the power after the wiring is completed, verify that the Do not disassemble the product. Doing so may cause power is correct, that there are no incorrect connections such as a shorted electric shock due to the high voltage portion. Burn also load circuit, and that the load current is suitable. Incorrect wiring may cause may result due to high temperature. Do not attempt to damage and failures. • Use the product with the specified voltage. Applying a voltage or AC voltage

disassemble, deform by pressure, incinerate, repair, or

that exceed the rating may result in burning or explosion of circuit Lighting side

modify this product.

components. Looking into the LED light continuously may cause visual • For cable extension between the lighting and lighting controller, use an optional extension cable (FLV-XC□/-XC□R) or branch cable (FLV-XC□

impairment. Do not look directly into the LED light.

S2). Only one extension cable and branch cable can be used. • The bending radius at cable wiring must be at least 20 mm. 4.Warming Up After turning on the power supply, allow the controller to stand for at least 30

CAUTION

minutes before use. As the circuits are unstable immediately after power on, brightness may gradually change.

Do not use it exceeding the rated voltage.

5. Lighting electricity

There is a possibility of failure and fire.

Lighting electricity for lighting equipment to be connected to the Lighting Controller is limited. Be sure to check the lighting electricity written on the

Do not connect amplifier units to AC power supply.

plate of the product, label of the packaging box or this manual to connect a

Risk of explosion.

lighting within the specified value. Beware of danger of burns. 6. Static Electricity Do not touch the case while the Lighting is ON or immediately LEDs are easily damaged by static electricity. A grounded wrist strap should after the power is turned OFF, since it is extremely hot. thus be used when installing or conducting maintenance on the Diffusion Board.

Page Summary Contents For OMRON Sensor Image Processing System FH Series FLV-FB[]Edge Type Lighting Instruction Sheet

Page 1 ■Specifications PRECAUTIONS FOR SAFE USE Item Model FLV-FB5050W FLV-FB7070W FLV-FB9090W FLV-FB130130W FLV-FB200200W Please observe the following precautions for safe use of the products. 1. Installati...
Page 2 ■Dimensions (Unit:mm) ●FLV-FB5050□ ●FLV-FB9090□ (MOUNTING HOLES) 4-3Dia. PENETRATION 66 ±0.2 3.5Dia. LENGTH0.8M 3.5Dia. LENGTH0.8M (1 0) MINIMUM BEND MINIMUM BEND RADIUS20 EMITTING SURFACE RADIUS20 EM...

Manual Details

Brand Image
Pages 2
File Size 363.09 KB
Published June 03, 2026
36 views

Enter the captcha to get the download link:

captcha

Frequently Asked Questions

What environments are prohibited for product use?

Do not use near flammable/explosive gas, or in locations subject to extreme temperature changes like icing or condensation.

How should I connect the lighting connector safely?

Ensure you turn off the unit's power when connecting or disconnecting the lighting connector to prevent malfunction.

What safety precautions must be followed during installation?

Do not install near high-voltage or power devices, and always wire high-voltage lines separately from the product.

What conditions should I monitor after use concerning heat?

The temperature may reach 70°C when supplied with power; do not touch the unit directly without wearing heat-resistant gloves.