# A B C D E F G H I J K L M N O P Q R S T U V W X Y Z

OMRON Sensor Image Processing System FH Series FLV-ATC[]1024-[] Analog Lighting Controller Instruction Sheet

Summary

This sophisticated analog lighting controller is designed for managing precise illumination of LED systems. The manual provides essential, comprehensive guidance covering safe installation practices, mandatory wiring protocols (including load capacity, proper grounding, and separation of high/low voltage lines), and operational safeguards. It serves as a critical technical reference for electrical professionals and automation technicians who require expert knowledge to install, operate, and maintain safe lighting control systems.

📄 Preview PAGE OF 2

Page 1 Text Content

■Parts Names and Functions

PRECAUTIONS FOR SAFE USE Please observe the following precautions for safe use of the products. 1.Installation Environment

• Do not use the product in environments where it can be exposed to

AC 240V

inflammable/explosive gas. • To secure the safety of operation and maintenance, do not install the

product close to high-voltage devices and power devices.

Model FLV-ATC□1024-□ TR2TS TR3 TR4TR1

• Do not touch the main unit with the conductive parts (metal parts) of peripheral devices. • To use the main unit, keep it well away from those devices. H3 H4C POWER Analog Lighting Controller 2.Power Supply and Wiring • Use a load that is equal to or less than the rating. • High-Voltage lines and power lines must be wired separately from this product. Wiring them together or placing them in the same duct may INSTRUCTION SHEET cause induction, resulting in malfunction or damage.

No. Name Description

• Take sufficient safety measures such as fail-safe circuit to use the product.

• Connect the Frame ground terminal to the ground completely. Main power supply Starts up the Controller when it is turned ON.

Thank you for selecting OMRON product. This sheet • When wiring the terminal block, use an applicable cable (AWG 14 to 24, Lighting adjustment volume Rotating the volume clockwise increases the emission intensity or counterclockwise decreases it. tip processing length: 7 mm).

primarily describes precautions required in installing and AC power supply input connector A terminal to supply AC power. Connect the provided AC input cable.

• Always turn off the power of the main unit before taking the following operating the product. actions. Not doing so may result in malfunction. Lighting connector Connects an LED lighting.  • Connecting/disconnecting the lighting connecting connector

Before operating the product, read the sheet thoroughly Terminal block for trigger input A terminal block for lighting illumination trigger input from outside to each lighting.

 • Inserting/removing the trigger input terminal block

to acquire sufficient knowledge of the product. For your 3.Others Lighting mode switching button Illumination mode switch button is ON(The button is pushed.):

convenience, keep the sheet at your disposal. • Do not use in safety circuits for atomic energy or that are critical for Short-circuiting (+) and (-) of TR1 to TR4 respectively makes the trigger input status ON, turning the light ON. TRACEABILITY INFORMATION: human life.

Releasing (+) and (-) makes the status OFF, turning the light OFF.

Representative in EU: Manufacturer: • Do not attempt to disassemble, deform by pressure, incinerate, repair, or

Omron Europe B.V. Omron Corporation, modify this product. Illumination mode switch button is OFF(The button is not pushed.): Wegalaan 67-69 Shiokoji Horikawa, Shimogyo-ku,

• When disposing of the product, treat as industrial waste. Short-circuiting (+) and (-) of TR1 to TR4 respectively makes the trigger input status OFF, turning the light OFF.

2132 JD Hoofddorp, Kyoto 600-8530 JAPAN

The Netherlands Ayabe Factory • Connect only an applicable lighting (FLV series).Use of other devices

3-2 Narutani, Nakayama-cho, Releasing (+) and (-) makes the status ON, turning the light ON.

may result in fire, explosion, malfunction or failure.

Ayabe-shi, Kyoto 623-0105 JAPAN • If you notice an abnormal condition such as a strange odor, extreme Frame ground terminal A terminal for frame ground. Connect the ground line.

heating of the unit, or smoke, immediately stop using the product, turn off

The following notice applies only to products that carry the CE mark:

the power, and consult your dealer.

Notice: ■Specifications

This is a class A product. In residential areas it may cause radio • Do not drop or impose excessive shock to the product. Doing so may interference, in which case the user may be required to take adequate result in damage to the product.

Item Model FLV-ATC21024-□ FLV-ATC41024-□

measures to reduce interference. • This product might be heated to around 70℃ in the room temperature

environment. So, do not touch it directly before putting heatproof gloves. Number of connectable lightings

• Ensure that all components which have locking mechanisms are locked

Applicable lighting FLV series(However, FLV-EP series and FLV-LN series are excluded.)

2279076-0B before using the product.

© OMRON Corporation 2013 All Rights Reserved. • Be careful not to drop the product when opening the crate and carrying it. Power supply voltage *2 100 to 240 VAC 50/60Hz

4.Regulations and standards

Current consumption 1A max.

This lighting complied with the EN standard (EN61326) with a EMC

directive (No.2004/108/EC). Electricity of connectable lighting 2ch total 40 W max. 4ch total 40 W max. 30 W max. for 1ch 30 W max. for 1ch Drive method Constant voltage method

PRECAUTIONS ON SAFETY PRECAUTIONS FOR CORRECT USE

Lighting method Trigger lighting, Continuous lighting

Observe the following to prevent failure, malfunctioning, and adverse

● Meanings of Signal Words Luminance control method Voltage light adjustment: 14.0 to 24.0 V

effects on performance and the device.

1.Installation site Trigger lighting Lighting in synchronization with input from the trigger input terminal

Indicates a potentially hazardous situation which, if

Do not install in the following locations: Trigger lighting delay time Ton:100μs max.

not avoided, will result in minor or moderate injury,

WARNING • Locations where the ambient temperature exceeds the rated temperature

or may result in serious injury or death. Additionally,

range. External interface Trigger input terminal block

there may be significant property damage.

• Locations subject to sudden temperature changes (where condensation Dielectric strength AC1500V 50/60Hz 1min Indicates a potentially hazardous situation which, if will form).

• Locations where the relative humidity is below or above 35 to 85% RH. Insulation resistance 20 MΩ (500VDC)

CAUTION not avoided, may result in minor or moderate injury

or in property damage. • Locations where there are corrosive or flammable gases. Ambient temperature Operating: 0 to +50℃, Storage: -15 to +60℃ (with no icing or condensation) • Locations where there is dust, salt, or iron powder.

Ambient humidity Operating/storage: 35% to 85% (with no condensation)

• Locations where the device will be subject to direct vibration or shock. ● Alert Statements in This Sheet • Locations where there is strong scattered light (laser light, arc welding Degree of protection IP20(IEC60529) light, ultraviolet light, etc.)

Vibration resistance(destructive) 10 to 150 Hz, (0.2mm double amplitude) 80 min each in X, Y, and Z directions

WARNING • Locations exposed to direct sunlight or next to a heater. • Locations where there is splashing or spraying of water, oil, or Shock resistance (destructive) 150 m/s2 3 times each in 6 directions(up/down, left/right, forward/backward) This product is not designed or rated for ensuring safety chemicals.

Materials Case:Aluminum

of persons either directly or indirectly. Do not use it for • Locations where there is a strong electrical or magnetic field.

such purposes. 2.Maintenance Weight Approx. 800g

• Do not install the product close to high-voltage devices and/or power

Do not disassemble the product. Doing so may cause Accessories Instruction sheet (this sheet), AC input cable *1

devices in order to secure the safety of operations and maintenance.

electric shock due to the high voltage portion. Burn also

• when inserting or removing the unit or cables, be sure to turn OFF the *1: The suffixed symbol of the model name means the plug shape of the accessory cable. A model name with no suffix means type A.

may result due to high temperature. Do not attempt to

power of the Controller first before operation.

disassemble, deform by pressure, incinerate, repair, or

• Never use paint thinner, benzine, acetone, or kerosene to clean the product. *2: This product is the exclusive use for apparatus inclusion in the industrial machine field.

modify this product.

3.Power and cable connections

• If there are surges on your power line, connect a surge absorber as This product cannot be used for the connection to electric power equipment, such as a common residence, store,

appropriate for your conditions of use. and small establishment, because of noncomformity with to Electrical Appliance and Material Safety Law (PSE).

CAUTION • Before turning on the power after the wiring is completed, verify that

the power is correct, that there are no incorrect connections such as a

Do not use it exceeding the rated voltage.

shorted load circuit, and that the load current is suitable. Incorrect wiring

There is a possibility of failure and fire.

may cause damage and failures. Looking into the LED light continuously may occasionally • For cable extension between the lighting and lighting controller, use an cause visual impairment. Do not look directly into the optional extension cable (FLV-XC□) or branching cable (FLV-XC□

LED light. S2). There are four types of cable length: 1m/2m/3m/5m.Only one

extension cable can be used.

Minor burns may occasionally occur.

• The bending radius for the wiring of lighting cable must be at least 20

Do not touch the case as it is very hot while the unit is

operating or immediately after turning OFF the power

4.Warming Up

supply Minor burns may occasionally occur.

After turning on the power supply, allow the controller to stand for at least 30 minutes before use. As the circuit is unstable immediately after the power ON, brightness may gradually change.

Page Summary Contents For OMRON Sensor Image Processing System FH Series FLV-ATC[]1024-[] Analog Lighting Controller Instruction Sheet

Page 1 ■Parts Names and Functions PRECAUTIONS FOR SAFE USE Please observe the following precautions for safe use of the products. 1.Installation Environment • Do not use the product in environments where it ...
Page 2 ■Connection with Lighting ■Connection with external trigger input terminal block 9. .5 ・Connection of this terminal block is not required if external lighting issuance trigger is not used. ■Mounting I...

Manual Details

Brand Image
Pages 2
File Size 1.38 MB
Published June 03, 2026
40 views

Enter the captcha to get the download link:

captcha

Frequently Asked Questions

Where should I install the lighting controller?

Do not use it in environments exposed to AC 100 - 240V inflammable/explosive gas, and keep it away from high-voltage devices.

Can I run my power lines and lighting cables together?

No. Wiring them together or placing them in the same duct may cause induction, leading to malfunction or damage.

What should I do if the unit shows signs of failure?

If you notice a strange odor, extreme heating, or smoke, immediately stop using the product and turn off the power, then consult your dealer.

Is the controller compatible with all types of lighting?

It can connect to the applicable FLV series, but users must exclude the FLV-EP and FLV-LN series.