The FLV-ATC is a robust, AC-powered lighting controller designed for precise regulation and management of line LED lighting in commercial or industrial environments. This manual serves as a comprehensive guide, detailing crucial information on safe installation protocols, proper electrical wiring (including dedicated power sources and grounding methods), operational guidelines, and technical specifications. It is essential reading for professionals responsible for integrating reliable, high-performance linear illumination systems into their overall facility equipment.
Page 1 Text Content
■Parts Names and Functions
PRECAUTIONS FOR SAFE USE Please observe the following precautions for safe use of the products. 1.Installation Environment • Do not use the product in environments where it can be exposed to inflammable/explosive gas. • To secure the safety of operation and maintenance, do not install the product close to high-voltage devices and power devices.
Model FLV-ATC□6024-□ • Do not touch the main unit with the conductive parts (metal parts) of
peripheral devices. • To use the main unit, keep it well away from those devices. Analog Lighting Controller for Line Lighting 2.Power Supply and Wiring • Use a load that is equal to or less than the rating. • High-Voltage lines and power lines must be wired separately from this product. Wiring them together or placing them in the same duct may INSTRUCTION SHEET cause induction, resulting in malfunction or damage. • Take sufficient safety measures such as fail-safe circuit to use the product. • Connect the Frame ground terminal to the ground completely.
• When wiring the terminal block, use an applicable cable (AWG 14 to 24, No. Name Description
Thank you for selecting OMRON product. This sheet
tip processing length: 7 mm).
Main power supply Starts up the Controller when it is turned ON.
primarily describes precautions required in installing and
• Always turn off the power of the main unit before taking the following
operating the product. actions. Not doing so may result in malfunction. Lighting adjustment volume Rotating the volume clockwise increases the emission intensity or counterclockwise decreases it.
• Connecting/disconnecting the lighting connecting connector AC power supply input connector A terminal to supply AC power. Connect the provided AC input cable.
Before operating the product, read the sheet thoroughly
• Inserting/removing the trigger input terminal block
to acquire sufficient knowledge of the product. For your Lighting connector Connects an LED lighting.
3.Others
convenience, keep the sheet at your disposal. • Do not use in safety circuits for atomic energy or that are critical for Terminal block for trigger input A terminal block for lighting illumination trigger input from outside to each lighting.
TRACEABILITY INFORMATION: human life. Frame ground terminal A terminal for frame ground. Connect the ground line. Representative in EU: Manufacturer: • Do not attempt to disassemble, deform by pressure, incinerate, repair, or
Omron Europe B.V. Omron Corporation, modify this product. Wegalaan 67-69 Shiokoji Horikawa, Shimogyo-ku, ■Specifications
• When disposing of the product, treat as industrial waste.
2132 JD Hoofddorp, Kyoto 600-8530 JAPAN
The Netherlands Ayabe Factory • Connect only an applicable lighting (FLV-LN series).Use of other
3-2 Narutani, Nakayama-cho, Item Model FLV-ATC26024-100V□ FLV-ATC26024-200V□
devices may result in fire, explosion, malfunction or failure.
Ayabe-shi, Kyoto 623-0105 JAPAN
• If you notice an abnormal condition such as a strange odor, extreme Number of connectable lightings The following notice applies only to products that carry the CE mark: heating of the unit, or smoke, immediately stop using the product, turn off
Applicable lighting FLV-LN series
Notice: the power, and consult your dealer.
This is a class A product. In residential areas it may cause radio • Do not drop or impose excessive shock to the product. Doing so may Power supply voltage *2 100 to 120 VAC 50/60Hz 200 to 240 VAC 50/60Hz
interference, in which case the user may be required to take adequate result in damage to the product.
Current consumption 7A max. 4A max.
measures to reduce interference. • This product might be heated to around 70℃ in the room temperature
environment. So, do not touch it directly before putting heatproof gloves. Electricity of connectable lighting 2ch total 240 W max.
• Ensure that all components which have locking mechanisms are locked 120 W max. for 1ch
2279377-7B before using the product.
© OMRON Corporation 2013 All Rights Reserved. • Be careful not to drop the product when opening the crate and carrying it. Drive method Constant current method
4.Regulations and standards Lighting method Trigger lighting, Continuous lighting This lighting complied with the EN standard (EN61326) with a EMC
directive (No.2004/108/EC). Luminance control method Current light adjustment ~5A
Trigger lighting Turning the light off in synchronization with input from the trigger input terminal
Trigger lighting delay time Ton:500μs max.
PRECAUTIONS ON SAFETY
PRECAUTIONS FOR CORRECT USE External interface Trigger input terminal block Dielectric strength AC1500V 50/60Hz 1min
● Meanings of Signal Words Observe the following to prevent failure, malfunctioning, and adverse
effects on performance and the device. Insulation resistance 20 MΩ (500VDC)
Indicates a potentially hazardous situation which, if
1.Installation site
not avoided, will result in minor or moderate injury, Ambient temperature Operating: 0 to +40℃, Storage: -15 to +60℃ (with no icing or condensation)
WARNING Do not install in the following locations:
or may result in serious injury or death. Additionally,
• Locations where the ambient temperature exceeds the rated temperature Ambient humidity Operating/storage: 35% to 85% (with no condensation)
there may be significant property damage.
range.
Degree of protection IP20(IEC60529)
• Locations subject to sudden temperature changes (where condensation
Indicates a potentially hazardous situation which, if
will form). Vibration resistance(destructive) 10 to 150 Hz, (0.2mm double amplitude) 80 min each in X, Y, and Z directions
CAUTION not avoided, may result in minor or moderate injury
• Locations where the relative humidity is below or above 35 to 85% RH.
or in property damage. Shock resistance (destructive) 150 m/s2 3 times each in 6 directions(up/down, left/right, forward/backward)
• Locations where there are corrosive or flammable gases.
• Locations where there is dust, salt, or iron powder. Materials Case:Aluminum
• Locations where the device will be subject to direct vibration or shock. Weight Approx. 2.1kg
● Alert Statements in This Sheet
• Locations where there is strong scattered light (laser light, arc welding
light, ultraviolet light, etc.) Accessories Instruction sheet (this sheet), AC input cable *1
WARNING
• Locations exposed to direct sunlight or next to a heater.
*1: The suffixed symbol of the model name means the plug shape of the accessory cable. A model name with no suffix means type A.
• Locations where there is splashing or spraying of water, oil, or
This product is not designed or rated for ensuring safety
of persons either directly or indirectly. Do not use it for chemicals. *2: This product is the exclusive use for apparatus inclusion in the industrial machine field. such purposes. • Locations where there is a strong electrical or magnetic field.
2.Maintenance This product cannot be used for the connection to electric power equipment, such as a common residence, store,
Do not disassemble the product. Doing so may cause • Do not install the product close to high-voltage devices and/or power and small establishment, because of noncomformity with to Electrical Appliance and Material Safety Law (PSE). electric shock due to the high voltage portion. Burn also devices in order to secure the safety of operations and maintenance. may result due to high temperature. Do not attempt to • when inserting or removing the unit or cables, be sure to turn OFF the disassemble, deform by pressure, incinerate, repair, or power of the Controller first before operation. modify this product. • Never use paint thinner, benzine, acetone, or kerosene to clean the product.
3.Power and cable connections • If there are surges on your power line, connect a surge absorber as
CAUTION appropriate for your conditions of use.
• Before turning on the power after the wiring is completed, verify that
Do not use it exceeding the rated voltage. the power is correct, that there are no incorrect connections such as a There is a possibility of failure and fire. shorted load circuit, and that the load current is suitable. Incorrect wiring
Looking into the LED light continuously may occasionally may cause damage and failures. cause visual impairment. Do not look directly into the •For cable extension between the lighting and lighting controller, use an LED light. optional extension cable (FLV-XC□LN) . There are four types of cable length: 1m/2m/3m/5m.Only one extension cable can be used.
Minor burns may occasionally occur. • The bending radius for the wiring of lighting cable must be at least 40 Do not touch the case as it is very hot while the unit is mm. operating or immediately after turning OFF the power
4.Warming Up
supply Minor burns may occasionally occur.
After turning on the power supply, allow the controller to stand for at least 30 minutes before use. As the circuit is unstable immediately after the power ON, brightness may gradually change.