OMRON Sensor Image Processing System FH Series FLV-CL[]Coaxial Lighting Instruction Sheet
Summary
Designed for industrial automation, this LED module system provides high-performance lighting solutions customizable by color and wattage. The accompanying manual is a critical resource, providing comprehensive safety protocols, installation guidelines, wiring instructions, and detailed environmental specifications. It is essential reading for electrical contractors, system integrators, and technical maintenance personnel who require safe and compliant setup of serious industrial lighting systems.
Page 1 Text Content
■Specifications
PRECAUTIONS FOR SAFE USE
Item Model FLV-CL30W FLV-CL40W FLV-CL60W FLV-CL80W FLV-CL100W
Please observe the following precautions for safe use of the products. 1. Installation Environment FLV-CL30R FLV-CL40R FLV-CL60R FLV-CL80R FLV-CL100R • Do not use the product in environments where it can be exposed to
FLV-CL30B FLV-CL40B FLV-CL60B FLV-CL80B FLV-CL100B
inflammable/explosive gas.
• To secure the safety of operation and maintenance, do not install the product Applicable Controllers FLV-TCC4□/-TCC1□/-TCC3HB□, FLV-ATC□1024-□
close to high-voltage devices and power devices.
Lighting color (peak wavelength) W:White, R:Red(Typ.635nm), B:Blue(Typ.460nm)
Model FLV-CL□ • Tighten the screws with the specified torque in this document.
2. Power Supply and Wiring Light source LED
• For details on power supply and wiring, refer to PRECAUTIONS FOR
LED Safety Risk Group 1(IEC62471)
SAFE USE on the INSTRUCTION SHEET of the dedicated controller
Coaxial Lighting (FLV-TCC4□/-TCC1□/-TCC3HB□, FLV-ATC□1024-□). Electricity White 2.4W 3.9W 10.4W 10.8W 22.7W
• When connecting or disconnecting the lighting connector, be sure to turn off Red 1.4W 2.3W 5.7W 7.2W 15.2W the power of the unit. Not doing so may result in malfunction.
• The temperature may reach 70°C while power is being supplied under Blue 2.4W 3.9W 10.4W 10.8W 22.7W
INSTRUCTION SHEET thermally neutral environment. Do not touch the product directly. Be sure to Insulation Resistance 20 MΩ (250VDC) wear heat-resistant gloves.
• High-Voltage lines and power lines must be wired separately from this Ambient Temperature Operating: 0 to +50℃, Storage: -15 to +60℃ (with no icing or condensation)
product. Wiring them together or placing them in the same duct may cause Ambient Humidity Operating and storage: 35% to 85% (with no condensation)
Thank you for selecting OMRON product. This sheet
induction, resulting in malfunction or damage.
Degree of Protection IP20(IEC60529)
primarily describes precautions required in installing and • Take sufficient safety measures such as fail-safe circuit to use the product. 3. Others Vibration Resistance(destructive) 10 to 150 Hz, (0.7mm double amplitude) 80 min. each in X, Y, and Z directions
operating the product.
• Do not use in safety circuits for atomic energy or that are critical for human life.
Before operating the product, read the sheet thoroughly Shock Resistance (destructive) 150 m/s2 3 times each in 6 directions(up/down, left/right, forward/backward)
• Do not attempt to disassemble, deform by pressure, incinerate, repair, or modify this product. Materials Case:Aluminum
to acquire sufficient knowledge of the product. For your
• When disposing of the product, treat as industrial waste.
convenience, keep the sheet at your disposal. Weight Approx.110g Approx.170g Approx.380g Approx.580g Approx.820g
• Be sure to connect a dedicated lighting controller (FLV-TCC4□/-TCC1□
TRACEABILITY INFORMATION: /-TCC3HB□, FLV-ATC□1024-□).Use of other devices may result in fire, Accessories Instruction sheet (this sheet)
Representative in EU: Manufacturer: explosion, malfunction or failure. Omron Europe B.V. Omron Corporation, • If you notice an abnormal condition such as a strange odor, extreme heating Wegalaan 67-69 Shiokoji Horikawa, Shimogyo-ku,
of the unit, or smoke, immediately stop using the product, turn off the power,
2132 JD Hoofddorp, Kyoto 600-8530 JAPAN
The Netherlands Ayabe Factory and consult your dealer. 3-2 Narutani, Nakayama-cho, • Do not drop or impose excessive vibration or shock on the product. It may
Ayabe-shi, Kyoto 623-0105 JAPAN cause breakdown of the product.
• Ensure that all components which have locking mechanisms are locked
The following notice applies only to products that carry the CE mark:
before using the product.
Notice: • Make sure not to drop the product when unpacking or moving it.
This is a class A product. In residential areas it may cause radio ■Connection with Lighting Controller
4. Regulations and standards
interference, in which case the user may be required to take adequate
This lighting complied with the EN standard (EN61326) with a EMC
measures to reduce interference.
directive (No.2004/108/EC). ・Mounting Align the positions of "the tab of the connector at the 2280615-1D lighting cable" and "protrusion of the lighting connector at
PRECAUTIONS FOR CORRECT USE
© OMRON Corporation 2013 All Rights Reserved. the Lighting Controller", and then insert it until it clicks.
Observe the following to prevent failure, malfunctioning, and adverse effects on performance and the device.
1. Installation site Before mounting After mounting
Do not install in the following locations:
• Locations where the ambient temperature exceeds the rated temperature range. Lighting Controller side
• Locations subject to sudden temperature changes (where condensation will form).
PRECAUTIONS ON SAFETY • Locations where the relative humidity is below or above 35 to 85% RH.
• Locations where there are corrosive or flammable gases.
● Meanings of Signal Words • Locations where there is dust, salt, or iron powder.
• Locations where the device will be subject to direct vibration or shock.
Indicates a potentially hazardous situation which, if not
• Locations where there is strong scattered light (laser light, arc welding light,
avoided, will result in minor or moderate injury, or may
WARNING ultraviolet light, etc.)
result in serious injury or death. Additionally, there may
• Locations exposed to direct sunlight or next to a heater.
be significant property damage. Lighting side
• Locations where there is splashing or spraying of water, oil, or chemicals. • Locations where there is a strong electrical or magnetic field.
Indicates a potentially hazardous situation which, if not 2. Maintenance
CAUTION avoided, may result in minor or moderate injury or in • Do not install the product close to high-voltage devices and/or power devices
property damage. in order to secure the safety of operations and maintenance.
• When this product and a cable are attached or removed, be sure to turn OFF ・Removing ● Alert Statements in This Sheet the power of the Controller first before operation.
Hold "the tab of the connector at the lighting cable" in the
• Never use paint thinner, benzen, acetone, or kerosene to clean the product.Wipe
the contamination with a soft cloth included a small amount of alcohol. arrow (←) direction and pull it straight.
WARNING
3. Power and cable connections [Note] This product is not designed or rated for ensuring safety of • When using a commercially available switching regulator, make sure that the
Do not pull out with excessive force without pressing the
persons either directly or indirectly. Do not use it for such Frame ground terminal is grounded.
• If there are surges on your power line, connect a surge absorber as tab. Doing so may break the wire.
purposes.
appropriate for your conditions of use. Do not disassemble the product. Doing so may cause • Before turning on the power after the wiring is completed, verify that the
Before removing After removing
electric shock due to the high voltage portion. Burn also power is correct, that there are no incorrect connections such as a shorted may result due to high temperature. Do not attempt to load circuit, and that the load current is suitable. Incorrect wiring may cause Lighting controller side disassemble, deform by pressure, incinerate, repair, or damage and failures. modify this product. • Use the product with the specified voltage. Applying a voltage or AC voltage that exceed the rating may result in burning or explosion of circuit components.
Looking into the LED light continuously may cause visual • For cable extension between the lighting and lighting controller, use an optional impairment. Do not look directly into the LED light. extension cable (FLV-XC□/-XC□R) or branch cable (FLV-XC□S2). Only
one extension cable and branch cable can be used. • The bending radius at cable wiring must be at least 20 mm. • In order to radiate a heat efficiently, set up the lighting with a space more than Lighting side
CAUTION
the heat radiation space (specified in the outline drawing) between the lighting and other devices.
Do not use it exceeding the rated voltage.
4.Warming Up
There is a possibility of failure and fire.
After turning on the power supply, allow the controller to stand for at least 30 minutes before use. As the circuits are unstable immediately after power on,
Do not connect amplifier units to AC power supply.
brightness may gradually change.
Risk of explosion.
5. Lighting electricity Beware of danger of burns. Lighting electricity for lighting equipment to be connected to the Lighting Do not touch the case while the Lighting is ON or immediately Controller is limited. Be sure to check the lighting electricity written on the after the power is turned OFF, since it is extremely hot. plate of the product, label of the packaging box or this manual to connect a lighting within the specified value. 6. Static Electricity LEDs are easily damaged by static electricity. A grounded wrist strap should thus be used when installing or conducting maintenance on the Diffusion Board.
Page Summary Contents For OMRON Sensor Image Processing System FH Series FLV-CL[]Coaxial Lighting Instruction Sheet
Manual Details
| Brand | Image |
|---|---|
| Pages | 2 |
| File Size | 353.77 KB |
| Published | June 03, 2026 |
Enter the captcha to get the download link:
Frequently Asked Questions
What must I do before connecting or disconnecting the lighting connector?
You must be sure to turn off the power of the unit first.
What should I do if I notice an abnormal condition, like a strange odor or extreme heating?
Immediately stop using the product, turn off the power, and consult your dealer.
What is the required tightening torque for proper installation?
The specified tightening torques are 1.2N・m and 2.3N・m.
What is the acceptable ambient operating temperature range?
The unit can operate in an ambient temperature range of 0 to +50°C, and storage temperatures are –15 to +60°C.