Engineered for demanding environments, this FLV series LED lighting system delivers precision illumination via connection with dedicated controllers. The accompanying manual serves as a comprehensive guide covering all aspects of installation and safe operation. It details critical specifications—including environmental tolerances (temperature, humidity), proper wiring procedures, mounting requirements, and essential safety precautions against electrical hazards, shock, and vibration. This resource is vital for automation engineers and industrial facilities managers seeking expert-grade, compliant lighting solutions for their critical infrastructure needs.
Page 1 Text Content
■Specifications
PRECAUTIONS FOR SAFE USE
Please observe the following precautions for safe use of the products. Item Model FLV- FLV- FLV- FLV- FLV- FLV- FLV- FLV- FLV- FLV- FLV- FLV-
1. Installation Environment LN82W LN142W LN322W LN442W LN122R LN222R LN322R LN422R LN82B LN142B LN322B LN442B • Do not use the product in environments where it can be exposed to inflammable/explosive gas.
• To secure the safety of operation and maintenance, do not install the product Applicable Controllers FLV-ATC□6024-□
close to high-voltage devices and power devices.
Lighting color (peak wavelength) White Red(Typ.625nm) Blue(Typ.460nm)
Model FLV-LN□ • Tighten the screws with the specified torque in this document.
2. Power Supply and Wiring Light source LED
• For details on power supply and wiring, refer to PRECAUTIONS FOR SAFE LED Safety Risk Group 3 (IEC62471) Risk Group 1 (IEC62471) Risk Group 2 (IEC62471) USE on the INSTRUCTION SHEET of the dedicated controller (FLV-ATC□
Electricity 9.2W 18.4W 45.9W 64.3W 10.4W 20.7W 31.1W 41.4W 9.2W 18.4W 45.9W 64.3W
Line Lighting 6024-□).
• When connecting or disconnecting the lighting connector, be sure to turn off Insulation Resistance 20 MΩ (250VDC) the power of the unit. Not doing so may result in malfunction.
Ambient Temperature Operating: 0 to +50℃, Storage: -15 to +60℃ (with no icing or condensation)
INSTRUCTION SHEET • The temperature may reach 70°C while power is being supplied under
thermally neutral environment. Do not touch the product directly. Be sure to Ambient Humidity Operating and storage: 35% to 85% (with no condensation)
wear heat-resistant gloves. Degree of Protection IP20(IEC60529)
Thank you for selecting OMRON product. This sheet • High-Voltage lines and power lines must be wired separately from this product.
Wiring them together or placing them in the same duct may cause induction, Vibration Resistance(destructive) 10 to 150 Hz, (0.7mm double amplitude) 80 min. each in X, Y, and Z directions
primarily describes precautions required in installing and
resulting in malfunction or damage. Shock Resistance (destructive) 150 m/s2 3 times each in 6 directions(up/down, left/right, forward/backward)
operating the product.
• Take sufficient safety measures such as fail-safe circuit to use the product.
Materials Case:Aluminum Cable:PVC
Before operating the product, read the sheet thoroughly 3. Others
• Do not use in safety circuits for atomic energy or that are critical for human life. Weight Approx.640g Approx.890g Approx.1950g Approx.2450g Approx.800g Approx.1320g Approx.1950g Approx.2400g Approx.640g Approx.890g Approx.1950g Approx.2450g
to acquire sufficient knowledge of the product. For your
• Do not attempt to disassemble, deform by pressure, incinerate, repair, or
Accessories Instruction sheet (this sheet)
convenience, keep the sheet at your disposal. modify this product.
• When disposing of the product, treat as industrial waste.
TRACEABILITY INFORMATION: • Be sure to connect a dedicated lighting controller (FLV-ATC□6024-□).Use Representative in EU: Manufacturer: of other devices may result in fire, explosion, malfunction or failure. Omron Europe B.V. Omron Corporation,
• If you notice an abnormal condition such as a strange odor, extreme heating of
Wegalaan 67-69 Shiokoji Horikawa, Shimogyo-ku,
2132 JD Hoofddorp, Kyoto 600-8530 JAPAN the unit, or smoke, immediately stop using the product, turn off the power, and
The Netherlands Ayabe Factory consult your dealer. ■Connection with the controller
3-2 Narutani, Nakayama-cho, • Do not drop or impose excessive vibration or shock on the product. Ayabe-shi, Kyoto 623-0105 JAPAN
It may cause breakdown of the product.
●Mounting
The following notice applies only to products that carry the CE mark: • Ensure that all components which have locking mechanisms are locked before
using the product. Align the groove of the cable with the protrusion of the
Notice:
This is a class A product. In residential areas it may cause radio • Make sure not to drop the product when unpacking or moving it. connector, and then push and rotate the screw clockwise.
interference, in which case the user may be required to take adequate 4. Regulations and standards
measures to reduce interference. This lighting complied with the EN standard (EN61326) with a EMC
directive (No.2004/108/EC). Before mounting After mounting
2279378-5C PRECAUTIONS FOR CORRECT USE
© OMRON Corporation 2013 All Rights Reserved. Controller side
Observe the following to prevent failure, malfunctioning, and adverse effects on performance and the device. 1. Installation site Do not install in the following locations: • Locations where the ambient temperature exceeds the rated temperature range. • Locations subject to sudden temperature changes (where condensation will form). PRECAUTIONS ON SAFETY • Locations where the relative humidity is below or above 35 to 85% RH. • Locations where there are corrosive or flammable gases. • Locations where there is dust, salt, or iron powder. Lighting side
● Meanings of Signal Words • Locations where the device will be subject to direct vibration or shock.
• Locations where there is strong scattered light (laser light, arc welding light,
Indicates a potentially hazardous situation which, if
ultraviolet light, etc.)
not avoided, will result in minor or moderate injury,
WARNING • Locations exposed to direct sunlight or next to a heater.
or may result in serious injury or death. Additionally, ●Removing
• Locations where there is splashing or spraying of water, oil, or chemicals.
there may be significant property damage.
• Locations where there is a strong electrical or magnetic field. Rotate the screw counterclockwise and pull the cable out of
2. Maintenance the connector.
Indicates a potentially hazardous situation which, if
• Do not install the product close to high-voltage devices and/or power devices
CAUTION not avoided, may result in minor or moderate injury
in order to secure the safety of operations and maintenance.
or in property damage.
• When this product and a cable are attached or removed, be sure to turn OFF Before removing After removing the power of the Controller first before operation.
● Alert Statements in This Sheet • Never use paint thinner, benzen, acetone, or kerosene to clean the product.Wipe
Controller side
the contamination with a soft cloth included a small amount of alcohol. WARNING 3. Power and cable connections • If there are surges on your power line, connect a surge absorber as
This product is not designed or rated for ensuring safety appropriate for your conditions of use. of persons either directly or indirectly. Do not use it for • Before turning on the power after the wiring is completed, verify that the such purposes. power is correct, that there are no incorrect connections such as a shorted load
circuit, and that the load current is suitable. Incorrect wiring may cause
Do not disassemble the product. Doing so may cause
damage and failures.
electric shock due to the high voltage portion. Burn also
• Use the product with the specified voltage. Applying a voltage or AC voltage
may result due to high temperature. Do not attempt to Lighting side
that exceed the rating may result in burning or explosion of circuit
disassemble, deform by pressure, incinerate, repair, or
components.
modify this product.
• For cable extension between the lighting and lighting controller, use an Looking into the LED light continuously may cause visual optional extension cable (FLV-XC□LN). There are four types of cable impairment. Do not look directly into the LED light. length: 1m/2m/3m/5m. Only one extension cable can be used. • The bending radius at cable wiring must be at least 40 mm. • In order to radiate a heat efficiently, set up the lighting with a space more than the heat radiation space (specified in the outline drawing) between the CAUTION lighting and other devices. 4.Warming Up
Do not use it exceeding the rated voltage. After turning on the power supply, allow the controller to stand for at least 30 There is a possibility of failure and fire. minutes before use. As the circuits are unstable immediately after power on,
brightness may gradually change.
Do not connect amplifier units to AC power supply. 5. Lighting electricity Risk of explosion. Lighting electricity for lighting equipment to be connected to the Lighting
Controller is limited. Be sure to check the lighting electricity written on the
Beware of danger of burns.
plate of the product, label of the packaging box or this manual to connect a
Do not touch the case while the Lighting is ON or immediately
lighting within the specified value.
after the power is turned OFF, since it is extremely hot.
6. Static Electricity LEDs are easily damaged by static electricity. A grounded wrist strap should thus be used when installing or conducting maintenance on the Diffusion Board.
Page Summary Contents For OMRON Sensor Image Processing Peripheral Equipment FLV Series FLV-LN[] Line Lighting Instruction Sheet
Manual Details
| Brand | Image |
|---|---|
| Pages | 2 |
| File Size | 1.36 MB |
| Published | June 03, 2026 |
Enter the captcha to get the download link:
Frequently Asked Questions
What environment should I avoid using this product in?
Do not use it near inflammable/explosive gases or locations subject to corrosive fumes.
What precautions must be taken when wiring the unit?
Always turn off power, and high-voltage lines must be wired separately from the lighting product.
What are the operating temperature and humidity ranges?
The ambient operating range is 0 to +50°C, 35% to 85% RH (non-condensing).
How should the unit be mounted securely?
Ensure all components with locking mechanisms are locked by rotating screws clockwise using the specified torque.