This comprehensive manual details the setup and operation of an Analog Lighting Controller designed for precise spot lighting management. It serves as a critical guide for electrical technicians, engineers, and installers responsible for maintaining commercial or industrial lighting systems. The document provides essential instructions on safe permanent installation, including proper wiring practices, grounding connections, high-voltage separation techniques, and operational safety precautions to ensure optimal performance and system longevity.

📄 Preview PAGE OF 2

Page 1 Text Content

■Parts Names and Functions

PRECAUTIONS FOR SAFE USE Please observe the following precautions for safe use of the products. 1.Installation Environment • Do not use the product in environments where it can be exposed to

CH1 CH2 CH3 CH4

inflammable/explosive gas. AC 240V • To secure the safety of operation and maintenance, do not install the product close to high-voltage devices and power devices.

Model FLV-ATC□0405-□ • Do not touch the main unit with the conductive parts (metal parts) of CH1 CH2

TR1 TR4TR3TR2

peripheral devices. • To use the main unit, keep it well away from those devices. Analog Lighting Controller for Spot Lighting 2.Power Supply and Wiring POWERCH3

• Use a load that is equal to or less than the rating. • High-Voltage lines and power lines must be wired separately from this product. Wiring them together or placing them in the same duct may INSTRUCTION SHEET cause induction, resulting in malfunction or damage. • Take sufficient safety measures such as fail-safe circuit to use the product.

• Connect the Frame ground terminal to the ground completely. No. Name Description

Thank you for selecting OMRON product. This sheet • When wiring the terminal block, use an applicable cable (AWG 14 to 24, Main power supply Starts up the Controller when it is turned ON. tip processing length: 7 mm).

primarily describes precautions required in installing and Lighting adjustment volume Rotating the volume clockwise increases the emission intensity or counterclockwise decreases it.

• Always turn off the power of the main unit before taking the following

operating the product. actions. Not doing so may result in malfunction. AC power supply input connector A terminal to supply AC power. Connect the provided AC input cable.

 • Connecting/disconnecting the lighting connecting connector Lighting connector Connects an LED lighting.

Before operating the product, read the sheet thoroughly

 • Inserting/removing the trigger input terminal block

to acquire sufficient knowledge of the product. For your 3.Others Terminal block for trigger input A terminal block for lighting illumination trigger input from outside to each lighting.

convenience, keep the sheet at your disposal. • Do not use in safety circuits for atomic energy or that are critical for Frame ground terminal A terminal for frame ground. Connect the ground line. TRACEABILITY INFORMATION: human life. Representative in EU: Manufacturer: • Do not attempt to disassemble, deform by pressure, incinerate, repair, or

Omron Europe B.V. Omron Corporation, modify this product. ■Specifications Wegalaan 67-69 Shiokoji Horikawa, Shimogyo-ku,

• When disposing of the product, treat as industrial waste.

2132 JD Hoofddorp, Kyoto 600-8530 JAPAN

• Connect only an applicable lighting (FLV-EP series).Use of other devices Item Model FLV-ATC10405-□ FLV-ATC40405-□

The Netherlands Ayabe Factory

3-2 Narutani, Nakayama-cho, may result in fire, explosion, malfunction or failure. Number of connectable lightings Ayabe-shi, Kyoto 623-0105 JAPAN

• If you notice an abnormal condition such as a strange odor, extreme

Applicable lighting FLV-EP series

The following notice applies only to products that carry the CE mark: heating of the unit, or smoke, immediately stop using the product, turn off Notice: the power, and consult your dealer. Power supply voltage *2 100 to 240 VAC 50/60Hz This is a class A product. In residential areas it may cause radio • Do not drop or impose excessive shock to the product. Doing so may

Current consumption 0.6A max.

interference, in which case the user may be required to take adequate result in damage to the product. measures to reduce interference. • This product might be heated to around 70℃ in the room temperature Electricity of connectable lighting 3 W max. 4ch total 12 W max.

environment. So, do not touch it directly before putting heatproof gloves.

3 W max. for 1ch

• Ensure that all components which have locking mechanisms are locked

2279944-9B before using the product. Drive method Constant current method

© OMRON Corporation 2013 All Rights Reserved. • Be careful not to drop the product when opening the crate and carrying it.

Lighting method Trigger lighting, Continuous lighting

4.Regulations and standards

This lighting complied with the EN standard (EN61326) with a EMC Luminance control method Current light adjustment ~0.4A

directive (No.2004/108/EC). Trigger lighting Turning the light off in synchronization with input from the trigger input terminal

Trigger lighting delay time Ton:1000μs max.

PRECAUTIONS ON SAFETY External interface Trigger input terminal block

PRECAUTIONS FOR CORRECT USE Dielectric strength AC1500V 50/60Hz 1min

● Meanings of Signal Words Observe the following to prevent failure, malfunctioning, and adverse Insulation resistance 20 MΩ (500VDC)

effects on performance and the device.

Indicates a potentially hazardous situation which, if Ambient temperature Operating: 0 to +50℃, Storage: -15 to +60℃ (with no icing or condensation)

1.Installation site

not avoided, will result in minor or moderate injury,

WARNING Do not install in the following locations: Ambient humidity Operating/storage: 35% to 85% (with no condensation)

or may result in serious injury or death. Additionally,

• Locations where the ambient temperature exceeds the rated temperature

there may be significant property damage. Degree of protection IP20(IEC60529)

range.

• Locations subject to sudden temperature changes (where condensation Vibration resistance(destructive) 10 to 150 Hz, (0.2mm double amplitude) 80 min each in X, Y, and Z directions

Indicates a potentially hazardous situation which, if

CAUTION not avoided, may result in minor or moderate injury will form).

Shock resistance (destructive) 150 m/s2 3 times each in 6 directions(up/down, left/right, forward/backward)

or in property damage. • Locations where the relative humidity is below or above 35 to 85% RH.

• Locations where there are corrosive or flammable gases. Materials Case:Aluminum

• Locations where there is dust, salt, or iron powder. Weight Approx. 800g • Locations where the device will be subject to direct vibration or shock.

● Alert Statements in This Sheet

• Locations where there is strong scattered light (laser light, arc welding Accessories Instruction sheet (this sheet), AC input cable *1

light, ultraviolet light, etc.)

WARNING

• Locations exposed to direct sunlight or next to a heater. *1: The suffixed symbol of the model name means the plug shape of the accessory cable. A model name with no suffix means type A. This product is not designed or rated for ensuring safety • Locations where there is splashing or spraying of water, oil, or of persons either directly or indirectly. Do not use it for chemicals.

*2: This product is the exclusive use for apparatus inclusion in the industrial machine field.

such purposes. • Locations where there is a strong electrical or magnetic field. 2.Maintenance This product cannot be used for the connection to electric power equipment, such as a common residence, store,

Do not disassemble the product. Doing so may cause • Do not install the product close to high-voltage devices and/or power

electric shock due to the high voltage portion. Burn also and small establishment, because of noncomformity with to Electrical Appliance and Material Safety Law (PSE).

devices in order to secure the safety of operations and maintenance.

may result due to high temperature. Do not attempt to • when inserting or removing the unit or cables, be sure to turn OFF the disassemble, deform by pressure, incinerate, repair, or power of the Controller first before operation. modify this product. • Never use paint thinner, benzine, acetone, or kerosene to clean the product.

3.Power and cable connections • If there are surges on your power line, connect a surge absorber as

CAUTION appropriate for your conditions of use.

• Before turning on the power after the wiring is completed, verify that

Do not use it exceeding the rated voltage.

the power is correct, that there are no incorrect connections such as a

There is a possibility of failure and fire.

shorted load circuit, and that the load current is suitable. Incorrect wiring Looking into the LED light continuously may occasionally may cause damage and failures. cause visual impairment. Do not look directly into the •For cable extension between the lighting and lighting controller, use an LED light. optional extension cable (FLV-XC□EP) . There are four types of cable length: 1m/2m/3m/5m.Only one extension cable can be used.

Minor burns may occasionally occur.

• The bending radius for the wiring of lighting cable must be at least 20

Do not touch the case as it is very hot while the unit is

operating or immediately after turning OFF the power

4.Warming Up

supply Minor burns may occasionally occur.

After turning on the power supply, allow the controller to stand for at least 30 minutes before use. As the circuit is unstable immediately after the power ON, brightness may gradually change.