This manual provides comprehensive instructions and critical safety guidelines for the installation, operation, and maintenance of advanced LED industrial lighting units. It details crucial procedures regarding environment suitability, electrical wiring, torque specifications, and system integration with dedicated controllers. Designed for technical professionals, engineers, and facility managers, this resource ensures safe handling and optimal performance when implementing these robust lighting solutions in demanding automation or commercial settings.
Page 1 Text Content
■Specifications
PRECAUTIONS FOR SAFE USE
Please observe the following precautions for safe use of the products. Item Model FLV-FR114W FLV-FR150W FLV-FP130W FLV-FS74W FLV-FQ48W
1. Installation Environment FLV-FR114R FLV-FR150R FLV-FP130R FLV-FS74R FLV-FQ48R • Do not use the product in environments where it can be exposed to
FLV-FR114B FLV-FR150B FLV-FP130B FLV-FS74B FLV-FQ48B
inflammable/explosive gas. Model FLV-FR□/-FP□ • To secure the safety of operation and maintenance, do not install the product Applicable Controllers FLV-TCC4□/-TCC1□/-TCC3HB□、FLV-ATC□1024-□ close to high-voltage devices and power devices.
Lighting color (peak wavelength) W:White、R:Red(Typ.635nm)、B:Blue(Typ.460nm) W:White、R:Red(Typ.625nm)、B:Blue(Typ.460nm)
• Tighten the screws with the specified torque in this document. 2. Power Supply and Wiring Light source LED • For details on power supply and wiring, refer to PRECAUTIONS FOR SAFE
LED Safety Risk Group 1(IEC62471)
-FS□/-FQ□ USE on the INSTRUCTION SHEET of the dedicated controller (FLV-TCC4□
/-TCC1□/-TCC3HB□, FLV-ATC□1024-□). Electricity White 3.9W 6.1W 8.1W 5.2W 2.0W
• When connecting or disconnecting the lighting connector, be sure to turn off the
Shadowless Lighting Red 3.1W 3.5W 5.8W 3.5W 1.2W
power of the unit. Not doing so may result in malfunction.
• The temperature may reach 70°C while power is being supplied under Blue 3.9W 6.1W 8.1W 5.2W 2.0W
thermally neutral environment. Do not touch the product directly. Be sure
INSTRUCTION SHEET Insulation Resistance 20 MΩ (250VDC)
to wear heat-resistant gloves.
• High-Voltage lines and power lines must be wired separately from this product. Ambient Temperature Operating: 0 to +50℃, Storage: -15 to +60℃ (with no icing or condensation)
Thank you for selecting OMRON product. This sheet Wiring them together or placing them in the same duct may cause induction,
Ambient Humidity Operating and storage: 35% to 85% (with no condensation)
primarily describes precautions required in installing and resulting in malfunction or damage.
• Take sufficient safety measures such as fail-safe circuit to use the product. Degree of Protection IP20(IEC60529)
operating the product. 3. Others
Vibration Resistance(destructive) 10 to 150 Hz, (0.7mm double amplitude) 80 min. each in X, Y, and Z directions
Before operating the product, read the sheet thoroughly • Do not use in safety circuits for atomic energy or that are critical for
human life. Shock Resistance (destructive) 150 m/s2 3 times each in 6 directions(up/down, left/right, forward/backward)
to acquire sufficient knowledge of the product. For your
• Do not attempt to disassemble, deform by pressure, incinerate, repair, or Materials Case:Aluminum,PMMA convenience, keep the sheet at your disposal. modify this product.
Weight Approx.270g Approx.500g Approx.320g Approx.140g Approx.100g
• When disposing of the product, treat as industrial waste.
TRACEABILITY INFORMATION:
• Be sure to connect a dedicated lighting controller (FLV-TCC4□/-TCC1□ Accessories Instruction sheet (this sheet)
Representative in EU: Manufacturer:
Omron Europe B.V. Omron Corporation, /-TCC3HB□, FLV-ATC□1024-□).Use of other devices may result in fire, Wegalaan 67-69 Shiokoji Horikawa, Shimogyo-ku, explosion, malfunction or failure.
2132 JD Hoofddorp, Kyoto 600-8530 JAPAN • If you notice an abnormal condition such as a strange odor, extreme The Netherlands Ayabe Factory heating of the unit, or smoke, immediately stop using the product, turn off the
3-2 Narutani, Nakayama-cho,
power, and consult your dealer. ■Connection with lighting controller
Ayabe-shi, Kyoto 623-0105 JAPAN
• Do not drop or impose excessive vibration or shock on the product. The following notice applies only to products that carry the CE mark: It may cause breakdown of the product.
• Ensure that all components which have locking mechanisms are locked before ●Mounting
Notice:
This is a class A product. In residential areas it may cause radio using the product. Align the positions of "the tab of the connector at the lighting interference, in which case the user may be required to take adequate • Make sure not to drop the product when unpacking or moving it.
cable" and "protrusion of the lighting connector at the lighting
measures to reduce interference. 4. Regulations and standards
This lighting complied with the EN standard (EN61326) with a EMC directive controller", and then insert it until it clicks.
(No.2004/108/EC).
Before mounting After mounting
© OMRON Corporation 2013 All Rights Reserved. PRECAUTIONS FOR CORRECT USE Lighting controller side
Observe the following to prevent failure, malfunctioning, and adverse effects on performance and the device. 1. Installation site Do not install in the following locations: • Locations where the ambient temperature exceeds the rated temperature range.
PRECAUTIONS ON SAFETY • Locations subject to sudden temperature changes (where condensation will form).
• Locations where the relative humidity is below or above 35 to 85% RH. • Locations where there are corrosive or flammable gases. Lighting side
● Meanings of Signal Words
• Locations where there is dust, salt, or iron powder. • Locations where the device will be subject to direct vibration or shock.
Indicates a potentially hazardous situation which, if
• Locations where there is strong scattered light (laser light, arc welding light,
not avoided, will result in minor or moderate injury,
WARNING ultraviolet light, etc.)
or may result in serious injury or death. Additionally,
• Locations exposed to direct sunlight or next to a heater.
there may be significant property damage. ●Removing
• Locations where there is splashing or spraying of water, oil, or chemicals.
• Locations where there is a strong electrical or magnetic field. Hold "the tab of the connector at the lighting cable" in the arrow
Indicates a potentially hazardous situation which, if
2. Maintenance (←) direction and pull it straight.
CAUTION not avoided, may result in minor or moderate injury
• Do not install the product close to high-voltage devices and/or power devices
or in property damage. 【Note】
in order to secure the safety of operations and maintenance. • When this product and a cable are attached or removed, be sure to turn OFF Do not pull out with excessive force without pressing the tab. the power of the Controller first before operation.
● Alert Statements in This Sheet • Never use paint thinner, benzen, acetone, or kerosene to clean the product.Wipe
the contamination with a soft cloth included a small amount of alcohol.
WARNING 3. Power and cable connections Before removing After removing
• When using a commercially available switching regulator, make sure that the
This product is not designed or rated for ensuring safety Frame ground terminal is grounded. Lighting controller side
of persons either directly or indirectly. Do not use it for • If there are surges on your power line, connect a surge absorber as such purposes. appropriate for your conditions of use. • Before turning on the power after the wiring is completed, verify that the
Do not disassemble the product. Doing so may cause power is correct, that there are no incorrect connections such as a shorted electric shock due to the high voltage portion. Burn also load circuit, and that the load current is suitable. Incorrect wiring may cause may result due to high temperature. Do not attempt to damage and failures.
disassemble, deform by pressure, incinerate, repair, or • Use the product with the specified voltage. Applying a voltage or AC voltage
Lighting side
modify this product. that exceed the rating may result in burning or explosion of circuit components.
Looking into the LED light continuously may cause visual • For cable extension between the lighting and lighting controller, use an
impairment. Do not look directly into the LED light. optional extension cable (FLV-XC□/-XC□R) or branch cable (FLV-XC□ S2). Only one extension cable and branch cable can be used. • The bending radius at cable wiring must be at least 20 mm. 4.Warming Up
CAUTION After turning on the power supply, allow the controller to stand for at least 30
minutes before use. As the circuits are unstable immediately after power on,
Do not use it exceeding the rated voltage.
brightness may gradually change.
There is a possibility of failure and fire. 5. Lighting electricity
Lighting electricity for lighting equipment to be connected to the Lighting
Do not connect amplifier units to AC power supply.
Controller is limited. Be sure to check the lighting electricity written on the
Risk of explosion.
plate of the product, label of the packaging box or this manual to connect a Beware of danger of burns. lighting within the specified value. Do not touch the case while the Lighting is ON or immediately 6. Static Electricity LEDs are easily damaged by static electricity. A grounded wrist strap should
after the power is turned OFF, since it is extremely hot.
thus be used when installing or conducting maintenance on the Diffusion Board.
Page Summary Contents For OMRON Sensor Image Processing Peripheral Equipment FLV Series FLV-FR[][][][] FP[][][][] FS[][][][] FQ[][][][] Shadowless Lighting Instruction Sheet
Manual Details
| Brand | Image |
|---|---|
| Pages | 2 |
| File Size | 395.88 KB |
| Published | June 03, 2026 |
Enter the captcha to get the download link:
Frequently Asked Questions
What should I do if I notice strange odors or smoke from the unit?
Immediately stop using the product, turn off the power, and consult your dealer.
Is a dedicated controller required for safe operation?
Yes; you must connect a dedicated lighting controller (such as FLV-TCC4□) before operating the product.
What are the acceptable ambient temperature and humidity ranges?
The recommended operating range is 0 to +50℃, and the relative humidity should be between 35% and 85%.