This essential guide provides comprehensive safety precautions and installation specifications for a series of high-powered industrial LED lighting modules. It details optimal environmental conditions, proper wiring procedures, and crucial handling steps to ensure safe integration into automated or industrial systems. This manual is designed for engineers, technicians, and system builders responsible for mounting or maintaining advanced lighting solutions within challenging operational environments.

📄 Preview PAGE OF 2

Page 1 Text Content

■Specifications

PRECAUTIONS FOR SAFE USE

Please observe the following precautions for safe use of the products. Item Model FLV-DL5890W FLV-DL7260W FLV-DL9090W FLV-DL12060W FLV-DL15060W

1. Installation Environment FLV-DL5890R FLV-DL7260R FLV-DL9090R FLV-DL12060R FLV-DL15060R • Do not use the product in environments where it can be exposed to

FLV-DL5890B FLV-DL7260B FLV-DL9090B FLV-DL12060B FLV-DL15060B

inflammable/explosive gas. • To secure the safety of operation and maintenance, do not install the Applicable Controllers FLV-TCC4□/-TCC1□/-TCC3HB□、FLV-ATC□1024-□ product close to high-voltage devices and power devices.

Lighting color (peak wavelength) W:White、R:Red(Typ.635nm)、B:Blue(Typ.460nm)

Model FLV-DL□ • Tighten the screws with the specified torque in this document.

2. Power Supply and Wiring Light source LED

• For details on power supply and wiring, refer to PRECAUTIONS FOR SAFE LED Safety Risk Group 1(IEC62471) USE on the INSTRUCTION SHEET of the dedicated controller (FLV-TCC4□

Low Angle Ring Lighting Electricity White 1.9W 5.7W 2.8W 12.7W 13.6W

/-TCC1□/-TCC3HB□,FLV-ATC□1024-□). • When connecting or disconnecting the lighting connector, be sure to turn Red 1.3W 3.9W 1.8W 10.5W 11.2W off the power of the unit. Not doing so may result in malfunction.

Blue 1.9W 5.7W 2.8W 12.7W 13.6W

INSTRUCTION SHEET • The temperature may reach 70°C while power is being supplied under

thermally neutral environment. Do not touch the product directly. Be sure Insulation Resistance 20 MΩ (250VDC)

to wear heat-resistant gloves.

Ambient Temperature Operating: 0 to +50℃, Storage: -15 to +60℃ (with no icing or condensation)

Thank you for selecting OMRON product. This sheet • High-Voltage lines and power lines must be wired separately from this product.

Wiring them together or placing them in the same duct may cause induction, Ambient Humidity Operating and storage: 35% to 85% (with no condensation)

primarily describes precautions required in installing and

resulting in malfunction or damage. Degree of Protection IP20(IEC60529)

operating the product. • Take sufficient safety measures such as fail-safe circuit to use the product.

Vibration Resistance(destructive) 10 to 150 Hz, (0.7mm double amplitude) 80 min. each in X, Y, and Z directions

Before operating the product, read the sheet thoroughly 3. Others • Do not use in safety circuits for atomic energy or that are critical for human life. Shock Resistance (destructive) 150 m/s2 3 times each in 6 directions(up/down, left/right, forward/backward)

to acquire sufficient knowledge of the product. For your

• Do not attempt to disassemble, deform by pressure, incinerate, repair, or modify

Materials Case:Aluminum

convenience, keep the sheet at your disposal. this product.

• When disposing of the product, treat as industrial waste. Weight Approx.90g Approx.120g Approx.100g Approx.310g Approx.260g

TRACEABILITY INFORMATION: • Be sure to connect a dedicated lighting controller (FLV-TCC4□/-TCC1□

Accessories Instruction sheet (this sheet)

Representative in EU: Manufacturer:

/-TCC3HB□, FLV-ATC□1024-□).Use of other devices may result in fire,

Omron Europe B.V. Omron Corporation,

Wegalaan 67-69 Shiokoji Horikawa, Shimogyo-ku, explosion, malfunction or failure. 2132 JD Hoofddorp, Kyoto 600-8530 JAPAN • If you notice an abnormal condition such as a strange odor, extreme

The Netherlands Ayabe Factory heating of the unit, or smoke, immediately stop using the product, turn off the

3-2 Narutani, Nakayama-cho, ■Connection with lighting controller

power, and consult your dealer.

Ayabe-shi, Kyoto 623-0105 JAPAN

• Do not drop or impose excessive vibration or shock on the product. The following notice applies only to products that carry the CE mark: It may cause breakdown of the product.

●Mounting

Notice: • Ensure that all components which have locking mechanisms are locked before

using the product. Align the positions of "the tab of the connector at the lighting

This is a class A product. In residential areas it may cause radio interference, in which case the user may be required to take adequate • Make sure not to drop the product when unpacking or moving it. cable" and "protrusion of the lighting connector at the lighting measures to reduce interference. 4. Regulations and standards

controller", and then insert it until it clicks.

This lighting complied with the EN standard (EN61326) with a EMC directive (No.2004/108/EC).

Before mounting After mounting

© OMRON Corporation 2013 All Rights Reserved. PRECAUTIONS FOR CORRECT USE Lighting controller side Observe the following to prevent failure, malfunctioning, and adverse effects on performance and the device. 1. Installation site Do not install in the following locations: • Locations where the ambient temperature exceeds the rated temperature range.

PRECAUTIONS ON SAFETY • Locations subject to sudden temperature changes (where condensation will form).

• Locations where the relative humidity is below or above 35 to 85% RH. • Locations where there are corrosive or flammable gases. Lighting side

● Meanings of Signal Words • Locations where there is dust, salt, or iron powder.

• Locations where the device will be subject to direct vibration or shock.

Indicates a potentially hazardous situation which, if

• Locations where there is strong scattered light (laser light, arc welding light,

not avoided, will result in minor or moderate injury,

WARNING ultraviolet light, etc.)

or may result in serious injury or death. Additionally,

• Locations exposed to direct sunlight or next to a heater.

there may be significant property damage. ●Removing

• Locations where there is splashing or spraying of water, oil, or chemicals.

Hold "the tab of the connector at the lighting cable" in the arrow

• Locations where there is a strong electrical or magnetic field.

Indicates a potentially hazardous situation which, if

2.Maintenance (←) direction and pull it straight.

CAUTION not avoided, may result in minor or moderate injury

• Do not install the product close to high-voltage devices and/or power devices

or in property damage. 【Note】

in order to secure the safety of operations and maintenance.

Do not pull out with excessive force without pressing the tab.

• When this product and a cable are attached or removed, be sure to turn OFF the power of the Controller first before operation.

● Alert Statements in This Sheet

• Never use paint thinner, benzen, acetone, or kerosene to clean the product.Wipe the contamination with a soft cloth included a small amount of alcohol. Before removing After removing

WARNING 3. Power and cable connections

• When using a commercially available switching regulator, make sure that the Lighting controller side

This product is not designed or rated for ensuring safety

Frame ground terminal is grounded.

of persons either directly or indirectly. Do not use it for

• If there are surges on your power line, connect a surge absorber as

such purposes.

appropriate for your conditions of use. • Before turning on the power after the wiring is completed, verify that the

Do not disassemble the product. Doing so may cause

power is correct, that there are no incorrect connections such as a shorted

electric shock due to the high voltage portion. Burn also

load circuit, and that the load current is suitable. Incorrect wiring may cause

may result due to high temperature. Do not attempt to

damage and failures.

disassemble, deform by pressure, incinerate, repair, or Lighting side

• Use the product with the specified voltage. Applying a voltage or AC voltage

modify this product.

that exceed the rating may result in burning or explosion of circuit components. Looking into the LED light continuously may cause visual • For cable extension between the lighting and lighting controller, use an impairment. Do not look directly into the LED light. optional extension cable (FLV-XC□/-XC□R) or branch cable (FLV-XC□ S2). Only one extension cable and branch cable can be used. • The bending radius at cable wiring must be at least 20 mm. 4.Warming Up

CAUTION After turning on the power supply, allow the controller to stand for at least 30

minutes before use. As the circuits are unstable immediately after power on,

Do not use it exceeding the rated voltage. brightness may gradually change. There is a possibility of failure and fire. 5. Lighting electricity

Lighting electricity for lighting equipment to be connected to the Lighting

Do not connect amplifier units to AC power supply.

Controller is limited. Be sure to check the lighting electricity written on the

Risk of explosion.

plate of the product, label of the packaging box or this manual to connect a lighting within the specified value.

Beware of danger of burns.

6. Static Electricity

Do not touch the case while the Lighting is ON or immediately

LEDs are easily damaged by static electricity. A grounded wrist strap should thus

after the power is turned OFF, since it is extremely hot.

be used when installing or conducting maintenance on the Diffusion Board.

Page Summary Contents For OMRON Image Processing System FH Series FLV-DL[] Low Angle Ring Lighting Instruction Sheet

Page 1 ■Specifications PRECAUTIONS FOR SAFE USE Please observe the following precautions for safe use of the products. Item Model FLV-DL5890W FLV-DL7260W FLV-DL9090W FLV-DL12060W FLV-DL15060W 1. Installation...
Page 2 ■Dimensions (Unit:mm) ●FLV-DL5890□ ●FLV-DL9090□ (8) ia (8) .C .D .3 (10.7) ±0 .2 (10.7) ia (10) (8) ia (10) 3.5Dia. LENGTH0.8M ia MINIMUM BEND RADIUS20 3.5Dia. LENGTH0.8M MINIMUM BEND RADIUS20 45Deg. ...

Manual Details

Brand Image
Pages 2
File Size 414.93 KB
Published June 03, 2026
24 views

Enter the captcha to get the download link:

captcha

Frequently Asked Questions

Where and how should I install the lighting unit?

Do not install in areas exposed to explosive gas or near high-voltage power devices. Use a dedicated controller unit for safe operation.

What safety precautions must be taken during operation?

Turn off the power of the unit before connecting or disconnecting the lighting connector, and do not touch the product directly due to potential heat buildup (up to 70°C).

How should I handle vibration and shock for longevity?

Do not drop or impose excessive vibration (10-150 Hz) or shock on the product, as this may cause breakdown. The ambient temperature range is 0 to +50℃.

Is there an impact on radio operation?

In residential areas, the usage of this lighting unit may cause radio interference, and the user might be required to take adequate measures to reduce it.