# A B C D E F G H I J K L M N O P Q R S T U V W X Y Z

OMRON Slim I O Relay G2RV-SR G3RV-SR Data Sheet

Summary

Designed for industrial automation professionals, the G2RV/G3RV series offers exceptional miniaturization with low-profile solid-state and electromagnetic relays (6.2mm width). These global standard components significantly reduce control panel size while enhancing reliability through Push-In Plus terminals and transparent casing for easy fault detection. This manual is your comprehensive guide covering model selection, common accessories, detailed wiring instructions, system safety precautions, and optimal integration strategies for reliable industrial power systems.

📄 Preview PAGE OF 34

Page 1 Text Content

2R V- 3R V-S recau tio ccesso ries

Slim I/O Relay

G2RV-SR/G3RV-SR Global standard size, low profile slim I/O relay with width 6.2 mm, slim I/O solid state relay Realized about 25% lower profile than conventional products, contributing to further miniaturization of the control panel. Push-In Plus technology are used to save wiring work in comparison with conventional screw terminals. (Wiring time is reduced by 60%* in comparison with traditional screw terminals.)

For the recent information on models that have been certified

No screw loosening means maintenance-free application,

for safety standards, refer to your OMRON website.

realizing high reliability ‘Hand-free’ structure that holds an inserted flat-blade screwdriver to achieve easier wiring work for stranded wires. Screw terminal is also stocked to meet the screw type needs. Mounted relay or solid-state relay has a plug-in terminal that is difficult to bend at the time of exchange. Coil surge absorption circuit is equipped as standard. According to OMRON actual measurement data from November 2015.

Refer to Safety Precautions on page 20.

Slim I/O Relay Types G2RV-SR series mounted relay: electromagnetic relay from page G3RV-SR series mounted relay: solid state relay from page

Common matter Common precautions from page Common accessories (order separately)................................. from page

Page Summary Contents For OMRON Slim I O Relay G2RV-SR G3RV-SR Data Sheet

Page 1 2R V- 3R V-S recau tio ccesso ries Slim I/O Relay G2RV-SR/G3RV-SR Global standard size, low profile slim I/O relay with width 6.2 mm, slim I/O solid state relay Realized about 25% lower profile than c...
Page 2 Slim I/O Relay G2RV-SR Global standard size, low profile slim I/O relay with width 6.2 mm Realized about 25% lower profile than conventional products, contributing to further miniaturization of the co...
Page 3 2R V-S 3R V-S recau tio ccesso ries G2RV-SR Model Number Structure Model Number Legend G2RV-SR @@ @ - @ @ (1) (2) (3) (5) (6)(4) (1) Basic model name (3) Terminal (wire connection) (5) Contact structu...
Page 4 G2RV-SR Relay for Maintenance Model Number Legend G2RV-1 - S @ - @ - G @ G2RV-1-SI-G G2RV-1-S(-AP)-G (1) No. of poles (4) Contact material 1: 1 pole Blank: Ag alloy AP: Ag alloy + Au plating (2) Termi...
Page 5 2R V-S 3R V-S recau tio ccesso ries G2RV-SR Specifications Ratings Coil ratings Must operate Must release Maximum Rated current Power consumption voltage voltage allowable voltage Rated input voltage ...
Page 6 G2RV-SR Approved standards um be of pe ra tio ns op er at io ns UL (File No.E41643) Model Contact form Operation coil ratings Contact ratings Operations 6 A at 250 VAC (Resistive load) 12 to 48 VDC G2...
Page 7 2R V-S 3R V-S recau tio ccesso ries G2RV-SR Dimensions (unit: mm) Slim I/O Relay + socket Push-In Plus Terminal Block Models without latching lever (without test switch) Terminal Arrangement/Internal ...
Page 8 G2RV-SR Screw terminal Models without latching lever (without test switch) Terminal Arrangement/Internal Connection Diagram G2RV-SR700 (TOP VIEW) G2RV-SR700-AP 12 VDC Input circuit 78 max. 74.1 Other ...
Page 9 2R V-S 3R V-S recau tio ccesso ries G2RV-SR Relay for maintenance Models without latching lever G2RV-1-S-G G2RV-1-S-AP-G 5.2 max. 30.5 max. Terminal Arrangement/ Internal Connection Diagram (TOP VIEW)...
Page 10 Slim I/O Solid State Relay G3RV-SR Global standard size, low profile type slim I/O solid state relay with width 6.2 mm. Realized about 25% lower profile than conventional products, contributing to fur...
Page 11 2R V-S 3R V-S recau tio ccesso ries G3RV-SR Model Number Structure Model Number Legend G3RV-SR @ @ @ - @ @ (1) (2) (3) (4) (5) (1) Basic model name (4) Output voltage specification G3RV: Slim I/O Soli...
Page 12 G3RV-SR Ordering Information Terminal Applicable Zero cross Rated input voltage Model (wire connection) output load function (V) G3RV-SR500-D DC12 G3RV-SR500-D DC24 G3RV-SR500-D AC/DC24 AC/DC G3RV-SR5...
Page 13 2R V-S 3R V-S recau tio ccesso ries G3RV-SR Solid state relay for maintenance Model Number Legend G3RV-@ @ S @ @ (1) Output voltage (3) Terminal specification S: Plug-in type D: DC output 2: AC output...
Page 14 G3RV-SR Specifications Rating (ambient temperature 25°C) Input G3RV-SR700/500-A series Rated current Input voltage Rated input Must operate Must release Percentage of the voltage voltage voltage rated...
Page 15 2R V-S 3R V-S recau tio ccesso ries G3RV-SR Characteristics Item G3RV-SR700/500-A G3RV-SR700/500-AL G3RV-SR700/500-D 1/2 cycle of load power supply Operate time 3 ms max. 6 ms max. +1 ms max. Release ...
Page 16 G3RV-SR Engineering Data Load current vs. ambient rated temperature In ru sh ur re nt .P ea k) Lo ad ur re nt Lo ad ur re nt G3RV-SR700/500-A(L) series Product mounting spacing 10 mm (Separate Mountin...
Page 17 2R V-S 3R V-S recau tio ccesso ries G3RV-SR Dimensions (unit: mm) Solid state relay + socket Push-In Plus Terminal Block G3RV-SR500 Terminal Arrangement/ Internal Connection Diagram (TOP VIEW) 12 VDC ...
Page 18 G3RV-SR Screw terminal G3RV-SR700 Terminal Arrangement/ Internal Connection Diagram (TOP VIEW) 12 VDC 78 max. Input circuit A1 Five, M2.6 INPUT A1+ 13 (+) OUTPUT The information in parentheses in for ...
Page 19 2R V-S 3R V-S recau tio ccesso ries G3RV-SR Solid state relay for maintenance G3RV-D03SL Terminal Arrangement/ Internal Connection Diagram G3RV-202S(L) (TOP VIEW) G3RV-D03SL (input circuit) Input 30.5...
Page 20 G2RV-SR/G3RV-SR Safety Precautions Be sure to read the Safety Precautions for All Relays in the website at the following URL: http://www.ia.omron.com/. Format of Warning Indications WARNING Indicates ...
Page 21 2R V-S 3R V-S recau tio ccesso ries G2RV-SR/G3RV-SR Precautions for Safe Use Transport Do not use the product if it has been dropped on the ground. Dropping the product may adversely affect performanc...
Page 22 G2RV-SR/G3RV-SR Precautions for Correct Use Do not use or store the product in the following locations. Doing so Completely inserted may result in damage, malfunction, or deterioration of performance ...
Page 23 2R V-S 3R V-S recau tio ccesso ries G2RV-SR/G3RV-SR G2RV-ST/G3RV-ST accessories are not compatible and cannot 2. Removing Wires from the Push-In Plus Terminal Block be used. Use the following procedur...
Page 24 G2RV-SR/G3RV-SR Recommended Flat-blade Screwdriver <G2RV> Use a flat-blade screwdriver to connect and remove wires. Operating latching lever (test switch) Use the following flat-blade screwdrive...
Page 25 2R V-S 3R V-S recau tio ccesso ries G2RV-SR/G3RV-SR ou nt in su rf ac <G3RV> <Ventilation Outside the Control Panel> Since the G3RV uses electronic components, do not allow it to fall, Be ...
Page 26 G2RV-SR/G3RV-SR For G2RV-SR/G3RV-SR Common Accessories (order separately) Ordering Information Short Bars No. of Minimum order Maximum energizing Appearance Pitch Colors Model * poles (Quantity) curre...
Page 27 2R V-S 3R V-S recau tio ccesso ries G2RV-SR/G3RV-SR Applicable Cables Cable Name Appearance length L Connecting Cables Applicable Connectors End A End B 1,000 P2RV-A100C Device PLC interface Cables wi...
Page 28 G2RV-SR/G3RV-SR Cable Name Appearance length L Connecting Cables Applicable Connectors (mm) 500 P2RV-050C-SCH-A End A End B 1,000 P2RV-100C-SCH-A Device PLC interface 32 input end unit end 2,000 P2RV-...
Page 29 2R V-S 3R V-S recau tio ccesso ries G2RV-SR/G3RV-SR PLC interface unit Ratings / characteristices Rated voltage 30 VAC/DC Rated current 0.5 A/poles, 2 A/unit Ambient operating temperature −40 to 55°C ...
Page 30 G2RV-SR/G3RV-SR Dimensions (unit: mm) PLC interface unit Push-IN P2RVC-8-I-5(-1) P2RVC-8-O-5(-1) Screw P2RVC-8-I-7-1 P2RVC-8-O-7-1 2R V-S 3R V-S recau tio ccesso ries
Page 31 2R V-S 3R V-S recau tio ccesso ries G2RV-SR/G3RV-SR (Except for PLC interface unit) Common Accessories (order separately) Dimensions (unit: mm) Short Bars PYDN-6.2-@@ (6.2 mm) Maximum carry Pitch No. ...
Page 32 G2RV-SR/G3RV-SR Safety Precautions Precautions for Correct Use When mounting a short bar Intermediate pins can be bent by a tool or by hand and cut off for use. Bend Cut off The short bar can be cut t...
Page 33 Terms and Conditions Agreement Read and understand this catalog. Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questi...
Page 34 Note: Do not use this document to operate the Unit. OMRON Corporation Industrial Automation Company Authorized Distributor: Kyoto, JAPAN Contact : www.ia.omron.com Regional Headquarters OMRON EUROPE B...

Manual Details

Brand Omron
Pages 34
File Size 8.88 MB
Published June 05, 2026
79 views

Enter the captcha to get the download link:

captcha

Frequently Asked Questions

What wire connection method does this relay use for easy wiring?

The relay uses Push-In Plus technology, which significantly reduces wiring time by 60% compared to traditional screw terminals.

How is maintenance facilitated when replacing the unit?

Mounted relays feature plug-in terminals that are difficult to bend at the time of exchange, ensuring easier and safer replacement.

Is this relay suitable for very small current loads?

Yes, micro load products are available for switching one pole up to 50 mA using Au-plated contacts.

What is the key difference between G2RV-SR and G3RV-SR models?

G2RV-SR models use an electromagnetic relay, while G3RV-SR models utilize a solid state relay.