Delta CMC-MOD01 Installation Instructions Modbus TCP Communication Card Optional Accessories

Summary

Enhance your industrial automation setup with this Modbus TCP communication card, designed specifically for Delta VFD-C2000 AC motor drives. This module enables seamless network integration via Ethernet, supporting 10/100 Mbps speeds and key protocols like Modbus TCP. The comprehensive manual provides technical experts and technicians with detailed instructions on installation, parameter configuration, wiring diagrams, and troubleshooting steps to ensure reliable, robust connectivity in demanding industrial environments.

📄 Preview PAGE OF 2

Page 1 Text Content

4. Twist open the other card clip to remove the PCB (see Figure 8).

Specifications 功能規格 Network Interface

網路介面 接頭 RJ-45 with Auto MDI/MDIX 埠數 1 Port 傳輸方式 IEEE 802.3, IEEE 802.3u 傳輸線 Category 5e shielding 100M 傳輸速率 10/100 Mbps Auto-Detect 網路協定 ICMP, IP, TCP, UDP, DHCP, HTTP, SMTP, MODBUS OVER TCP/IP, Delta Configuration

Interface RJ-45 with Auto MDI/MDIX

Number of ports 1 Port

Transmission method IEEE 802.3, IEEE 802.3u

Transmission cable Category 5e shielding 100M

[Figure 6] [Figure 7] [Figure 8]

Transmission speed 10/100 Mbps Auto-Detect

Network protocol ICMP, IP, TCP, UDP, DHCP, HTTP, SMTP, MODBUS OVER TCP/IP, Delta Configuration LED Indicator & Troubleshooting

There are 2 LED indicators on CMC-MOD01. The POWER LED displays the status of power supply, and the

Electrical Specification

LINK LED displays the connection status of the communication. 電氣規格 重量 25g 絕緣電壓 500VDC 消耗電力 0.8W 電源電壓 5VDC

Weight 25g

LED Indicators

Insulation voltage 500VDC

Power consumption 0.8W LED Status Indication How to correct

On Power supply in normal status --

Power supply voltage 5VDC POWER Green

Off No power supply Check the power supply

Environment On Network connection in normal status --

Flashes Network in operation -- LINK Green

ESD (IEC 61800-5-1, IEC 61000-4-2)

Off Network not connected Check if the network cable is connected ESD (IEC 61800-5-1, IEC 61000-4-2)

EFT (IEC 61800-5-1, IEC 61000-4-4)

Noise immunity EFT (IEC 61800-5-1, IEC 61000-4-4)

Surge Test (IEC 61800-5-1, IEC 61000-4-5)

Surge Test (IEC 61800-5-1, IEC 61000-4-5)

Conducted Susceptibility Test (IEC 61800-5-1, IEC 61000-4-6) Troubleshooting

Conducted Susceptibility Test (IEC 61800-5-1, IEC 61000-4-6) 操作∕儲存環境

Operation: -10°C ~ 50°C (temperature), 90% (humidity)

Operation/storage Abnormality Cause How to correct 操作:-10°C ~ 50°C(溫度),90%(濕度) 儲存:-25°C ~ 70°C(溫度),95%(濕度) 耐振動∕衝擊 國際標準規範 IEC 61800-5-1,IEC 60068-2-6 / IEC 61800-5-1,IEC 60068-2-27

Storage: -25°C ~ 70°C (temperature), 95% (humidity)

Check if AC motor drive is powered, and if the power supply

Vibration/shock AC motor drive not powered

International standard: IEC 61800-5-1, IEC 60068-2-6/IEC 61800-5-1, IEC 60068-2-27 is normal.

immunity POWER LED off

CMC-MOD01 not connected to

Make sure CMC-MOD01 is connected to AC motor drive.

AC motor drive CMC-MOD01 not connected to Make sure the network cable is correctly connected to

Installation network network. LINK LED off 安裝

Poor contact to RJ-45 connector Make sure RJ-45 connector is connected to Ethernet port.

Connecting CMC-MOD01 to Network

CMC-MOD01 not connected to CMC-MOD01與網路連接

Make sure CMC-MOD01 is connected to network.

1. Switch off the power of AC motor drive. network

No module found PC and CMC-MOD01 in different 1. 關閉交流馬達驅動器電源。

2. Open the front cover of AC motor drive. Search by IP or set up relevant settings by AC motor drive

networks and blocked by 2. 打開交流馬達驅動器上蓋。

keypad.

3. Connect CAT-5e network cable to RJ-45 port on CMC-MOD01 network firewall.

3. 連接 CAT-5e 網路線至 CMC-MOD01 RJ-45 接孔,如圖[2]所示。

(See Figure 2). CMC-MOD01 not connected to

Make sure CMC-MOD01 is connected to the network.

network

[Figure 2]

Fail to open Incorrect communication setting Make sure the communication setting in DCISoft is set to [圖 2] CMC-MOD01 setup in DCISoft Ethernet.

RJ-45 PIN Definition page PC and CMC-MOD01 in different

RJ-45連接器腳位定義 腳 位 訊 號 敘 述 腳 位 訊 號 敘 述

networks and blocked by Conduct the setup by AC motor drive keypad.

PIN Signal Definition PIN Signal Definition network firewall.

Positive pole for data Able to open Check if the network setting for CMC-MOD01 is correct. For

1 Tx+ 5 -- N/C 1 Tx+ 傳輸資料正極 5 -- N/C

transmission CMC-MOD01 setup Incorrect network setting in the Intranet setting in your company, please consult your IT page but fail to utilize CMC-MOD01 staff. For the Internet setting in your home, please refer to

Negative pole for data 2 Tx- 傳輸資料負極 6 Rx- 接收資料負極

2 Tx- 6 Rx- Negative pole for data receiving webpage monitoring the network setting instruction provided by your ISP.

transmission 3 Rx+ 接收資料正極 7 -- N/C

Incorrect network setting in

3 Rx+ Positive pole for data receiving 7 -- N/C Check if the network setting for CMC-MOD01 is correct.

Fail to send e-mail CMC-MOD01

CMC-1206030-02 4 -- N/C 8 -- N/C Incorrect mail server setting Please confirm the IP address for SMTP-Server.

ENGLISH Connecting CMC-MOD01 to VFD-C2000 繁體中文 CMC-MOD01安裝於 VFD-C2000系列交流馬達驅動器上

Warning 注意事項

1. Switch off the power supply of VFD-C2000. 1. 關閉交流馬達驅動器電源。

This instruction sheet only provides information on electrical specification, general specification, how to install and 此安裝手冊只提供電氣規格、一般規格、安裝及配線等。詳細關於 CMC-MOD01包含的網路協定內容,請參閱相關的專業文章或書籍資料。交流馬達驅動器安裝環境及方式及注意事項請參考交流馬達驅動器手冊。

2. Open the front cover of VFD-C2000.

wire. More details regarding the network protocol in CMC-MOD01, please refer to professional articles or 2. 打開交流馬達驅動器上蓋。

literaures. For the installation environment, method and notes of AC motor drive, please refer to the user manual of 3. Place the insulation spacer into the positioning pin at Slot 1 (shown in Figure 3), and aim the two holes on

the PCB at the positioning pin. Press the pin to clip the holes with the PCB (see Figure 4). 3. 於[圖 3]顯示的 Slot1 處,先將絕緣片放入定位柱後,再將 PCB 上兩個圓孔對準定位柱後,下壓讓兩個卡勾卡住

AC motor drive. 安裝本產品時,請先關閉交流馬達驅動器電源。交流馬達驅動器的內部電路板有 CMOS IC極易受靜電的破壞,故在未做好防靜電措施前請勿用手觸摸電路板。

4. Screw up at torque 6 ~ 8 kg-cm (5.21 ~ 6.94 in-lbs) after the PCB is clipped with the holes (see Figure 5). PCB,如[圖 4]所示。

Switch off the power supply of AC motor drive before installing CMC-MOD01. The circuit inside AC motor drive

has CMOS IC in it which is particularly sensitive to static electricity. Please DO NOT touch the circuit board before 4. 確認 PCB 上兩個卡勾確實卡住 PCB 後,將螺絲鎖上,扭力為 6~8 kg-cm (5.21~6.94 in-lbs),如[圖 5]所示。

the precaution against static electricity is done. Slot 3 本機屬於交流馬達驅動器之配件卡,使用者使用本產品時,必須將之安裝於 VFD-C2000系列交流馬達驅動器上。

CMC-MOD01 is the accessory of and has to be installed on VFD-C2000 series AC motor drive. Slot 3

Slot 1Slot 2

The IC on circuit board can be easily damaged by static electricity; therefore DO NOT touch it before precautions 電路板上的 IC易受靜電破壞,未做好防靜電措施前請勿用手觸摸。防止非維護人員操作或意外衝擊本體,造成危險及損壞,且請勿在上電時觸摸任何端子。 Slot 1Slot 2

against static electricity are done. Non-maintenance staff should not operate or accidentally hit the body of CMC-MOD01 in case danger and damage may occur. DO NOT touch any terminaals when the power is switched

on. 請務必仔細閱讀本安裝說明,並依照說明指示進行操作,以免造成產品受損,或導致人員受傷。

Please read this instruction sheet thoroughly and follow the instructions in case damage on the device or injury of the operation staff occur. [Figure 3] [Figure 4] [Figure 5]

Introduction Communication Parameters for VFD-C2000 Connected to Modbus CMC-MOD01 通訊卡。CMC-MOD01 定義為 Modbus TCP 通訊卡,用於將台達 VFD-C2000 系列交流馬達驅動器接入

Thank you for choosing Delta CMC-MOD01 communication card. CMC-MOD01 is Modbus TCP When VFD-C2000 is connected to Modbus network, please set up the communication parameters for it Modbus TCP 網路,CMC-MOD01 無需外接電源,由交流馬達驅動器提供。 VFD-C2000連接 Ethernet網路時的通訊參數設定 台達 communication card for connecting Delta VFD-C2000 series AC motor drive to Modbus TCP network. No according to the table below. The Modbus master is only able to read/write the frequency word and control

VFD-C2000 驅動器連接 Ethernet 網路時,須根據表格設定交流馬達驅動器的通訊參數。設置通訊參數後,

word of VFD-C2000 after the communication parameters are set.

external power supply is required for CMC-MOD01. The power will be supplied by AC motor drive. 功能特色 Ethernet 主站才可以對台達 VFD-C2000 驅動器的頻率字元組和控制字元組進行讀寫操作。

Parameter (Dec) Function Set value (Dec) Explanation

Functions 1. 支援 Modbus TCP 協定 4. 電子郵件警報 C2000 參數(Dec) 參數說明 當前設定值(Dec) 參數設定值定義

P00-20 Setting up source of The frequency command is controlled by

frequency command communication card. 2. MDI/MDI-X 自動偵測 5. 交流馬達驅動器操作器∕Ethernet 組態設定

1. Supports Modbus TCP protocol 4. E-mail alarm P00-20 頻率指令來源設定 8 頻率命令由通訊卡控制

Setting up source of The operation command is controlled by 3. 傳輸速率 10/100Mbps 自動偵測 6. 虛擬序列埠

2. MDI/MDI-X auto-detect 5. AC motor drive keypad/Ethernet configuration P00-21 P00-21 運轉指令來源設定 5 運轉命令由通訊卡控制

operation command communication card. 3. Baud rate: 10/100Mbps auto-detect 6. Virtual serial port P09-30 Decoding method for 0 The decoding method for Delta AC motor drive P09-30 通訊解碼方式 0 台達交流馬達驅動器解碼方式

communication 產品外觀

P09-75 IP 設定 0 靜態 IP(0) / 動態分派 IP(1)

Product Profile P09-75 IP setting 0 Static IP(0) / Dynamic distribution IP(1)

P09-76 IP 地址-1 192 IP 地址 192.168.1.5

P09-76 IP address -1 192 IP address 192.168.1.5

P09-77 IP 地址-2 168 IP 地址 192.168.1.5

P09-77 IP address -2 168 IP address 192.168.1.5

P09-78 IP 地址-3 1 IP 地址 192.168.1.5

P09-78 IP address -3 1 IP address 192.168.1.5

P09-79 IP 地址-4 5 IP 地址 192.168.1.5

P09-79 IP address -4 5 IP address 192.168.1.5

P09-80 Netmask -1 255 Netmask 255.255.255.0

P09-81 Netmask -2 255 Netmask 255.255.255.0

P09-82 Netmask -3 255 Netmask 255.255.255.0

P09-83 Netmask -4 0 Netmask 255.255.255.0

P09-84 Default gateway -1 192 Default gateway 192.168.1.1

P09-85 Default gateway -2 168 Default gateway 192.168.1.1

P09-86 Default gateway -3 1 Default gateway 192.168.1.1

P09-87 Default gateway -4 1 Default gateway 192.168.1.1

[Figure 1] 1. 螺絲固定孔 2. 通訊卡定位孔 3. 交流馬達驅動器連接埠

Disconnecting CMC- MOD01 from VFD-C2000 CMC- MOD01從 VFD-C2000系列交流馬達驅動器上卸除

4. LINK 指示燈 5. RJ-45 連接埠 6. POWER 指示燈 1. 關閉交流馬達驅動器電源。

1. Screw fixing hole 2. Positioning hole 3. AC motor drive connection port 1. Switch off the power supply of VFD-C2000.

2. Remove the two screws (see Figure 6). 7. 通訊卡防呆溝槽 2. 將兩顆螺絲拆下,如[圖 6]所示。

4. LINK indicator 5. RJ-45 connection port 6. POWER indicator

3. Twist open the card clip and insert the slot type screwdriver to the hollow to prize the PCB off the card clip 3. 將卡勾扳開後,將一字起子斜插入凹陷處,將 PCB 撬開脫離卡勾,如[圖 7]所示。

7. Fool-proof groove (see Figure 7).

4. 再將另一卡勾扳開後,將 PCB 取出,如[圖 8]所示。

Page Summary Contents For Delta CMC-MOD01 Installation Instructions Modbus TCP Communication Card Optional Accessories

Page 1 4. Twist open the other card clip to remove the PCB (see Figure 8). Specifications 功能規格 Network Interface 網路介面 接頭 RJ-45 with Auto MDI/MDIX 埠數 1 Port 傳輸方式 IEEE 802.3, IEEE 802.3u 傳輸線 Category 5e shield...
Page 2 功能規格 網路介面 接头 RJ-45 with Auto MDI/MDIX 埠数 1 Port 传输方式 IEEE 802.3, IEEE 802.3u 传输线 Category 5e shielding 100M 传输速率 10/100 Mbps Auto-Detect 网络协议 ICMP, IP, TCP, UDP, DHCP, HTTP, SMTP, MODBUS OVER TCP/IP, ...

Manual Details

Brand Delta
Pages 2
File Size 658.14 KB
Published June 05, 2026
14 views

Enter the captcha to get the download link:

captcha

Frequently Asked Questions

What safety measures must I take when handling the PCB?

Always use anti-static precautions, as the circuits are highly susceptible to static electricity damage.

How do I check if my network connection is functional?

Check the LINK LED indicator; a green flashing light indicates the network is operating normally.

What is the maximum transmission speed and type supported?

The card supports 10/100 Mbps auto-detect using IEEE 802.3 and IEEE 802.3u standards.

If I cannot send emails, what should I verify?

Verify that the IP address for the SMTP-Server is set correctly in your configuration.