Texas Instruments bq24200, bq24201, bq24202, bq24203, bq24204, bq24205 Data Sheet Manual
Summary
The bq2420x series is a highly integrated, low-cost linear charge management device for single-cell Li-Ion batteries, ideal for space-limited or low-dropout charger designs. This manual provides comprehensive technical specifications and application details covering robust charging cycles, automatic pre-charge conditioning, and sleep mode functionality. Engineers can leverage advanced features like external temperature monitoring (TSTAT) and a dedicated charge status output (STAT) to ensure optimal battery health while building reliable, compact power solutions.
Page 1 Text Content
SLUS501A – OCTOBER 2001
FEATURES DESCRIPTION Designed Specifically to Work With
The bq2420x series are simple Li-Ion linear
Current-Limited Wall Supplies
charge management devices targeted at low-cost
Ideal for Low Dropout Charger Design for and space limited charger applications. The Single-Cell Li-Ion Packs With Coke or bq2420x series offer integrated power FET, Graphite Anodes high-accuracy voltage regulation, temperature
monitoring, charge status, and charge
Integrated Power FET for 500 m A
termination, in a single monolithic device.
Integrated Voltage Regulation With 0.5% Accuracy The bq2420x is designed to work with a
current-limited wall-mount transformer and
Battery Insertion and Removal Detection
therefore does not provide any current regulation.
Charge Termination by Minimum Current and
However, these devices offer a fixed internal
current limit to prevent damage to the internal
Pre-Charge Conditioning With Safety Timer
power FET. A time-limited pre-conditioning phase
Sleep Mode for Low-Power Consumption is provided to condition deeply discharged cells.
Once the battery reaches the charge voltage, the
Charge Status Output for LED or Host
high accuracy voltage regulation loop takes over
Processor Interface Indicates
and completes the charge cycle. Charge is
Charge-in-Progress, Charge Completion, and
terminated based on minimum current. An internal
Fault Conditions
charge timer provides a backup safety for charge
Optional Temperature Monitoring Before and
termination.
During Charge
Other standard features include an automatic
Small, 8-Pin Power-Pad MSOP Package
sleep mode activated when VCC falls below the battery voltage and a recharge feature activated when the battery voltage falls below the VRCH
TYPICAL APPLICATION
threshold.
bq24202DGN
DC+ In addition to the standard features, the core product provides two additional enhancements:
OUT 8IN
temperature monitoring and status display. The
C1 temperature-sense circuit continuously measures
VCC 7BAT
battery temperature using an external thermistor and inhibits charge until the battery temperature is
STAT 6CE within the user–defined thresholds. The STAT pin
indicates three conditions of operation of the
R1 charger. These conditions are charge-
VSS 5N/C
in-progress, charge complete, and fault. This
BATTERY PACK
output can be used to drive an LED or an interface
UDG–01111
to a microcontroller.
!"#$ % &'!!($ #% )'*&#$ +#$(, Copyright 2001, Texas Instruments Incorporated ! +'&$% & !" $ %)(&&#$ % )(! $-( $(!"% (.#% %$!'"($% %$#+#!+ /#!!#$0, ! +'&$ )! &(%%1 + (% $ (&(%%#!*0 &*'+( $(%$1 #** )#!#"($(!%,
1www.ti.com
Page Summary Contents For Texas Instruments bq24200, bq24201, bq24202, bq24203, bq24204, bq24205 Data Sheet Manual
Manual Details
| Brand | Texas Instruments |
|---|---|
| Pages | 16 |
| File Size | 229.62 KB |
| Published | July 10, 2026 |
Enter the captcha to get the download link:
Frequently Asked Questions
What type of batteries are these charge management devices designed for?
They are targeted at low-cost Li-Ion linear Current-Limited Wall Supplies.
How does the system handle battery over-temperature conditions?
It uses an external thermistor and continuous monitoring on the TS pin; charging is inhibited if the temperature exceeds defined user thresholds.
What indicators signal that the charge cycle has completed or failed?
The STAT pin indicates three conditions: Charge In-Progress, Charge Complete, or Fault. The module also provides a Charge Status Output for LEDs.
Is this charger suitable for space and low power applications?
Yes, it is ideal for Low Dropout Charger Design and other space limited charger applications.