OMRON PLC Mechanical Controller IPC Multi-Axis Controller Touch Panel UHF with RFID System V780 Series V780-HMD68-ETN-[][]UHF RFID System Reader Writer Instruction Sheet

Summary

The Omron UHF RFID Reader/Writer is a robust component designed for integrating RF Tag reading into industrial automation systems. This comprehensive manual guide provides step-by-step instructions necessary for system setup and deployment. It covers complete hardware installation, including front and rear mounting procedures. Furthermore, users will learn critical networking tasks, such as configuring fixed IP addresses or utilizing BOOTP servers. The document concludes with detailed communication diagnostics tools, allowing technicians to verify the optimal performance of the entire RFID system before live operation.

📄 Preview PAGE OF 2

Page 1 Text Content

2. Set the IP address of the Reader/Writer. Connecting the System STEP Click the Network settings Button on the left of the Web Browser Operation

UHF RFID System 4-22

Window and select one of the following settings.

1. Connect the Reader/Writer to a 24-VDC power supply and switching hub.

 Setting a Fixed IP Address

Reader/Writer Model V780-HMD68-ETN-@@ Reader/Writer

The system requirements to use the Web browser are as follows: On the Network Settings View, select the Fixed setting Option, enter the IP

V780-HMD68-ETN-@@

Thank you for selecting an OMRON product. · Windows 8.1/Windows 10 address, subnet mask, and gateway address, and then click the Set Button. · Internet Explorer 11/Microsoft Edge/Google Chrome

This Guide describes the steps that are required from installation of the

 Getting an IP Address from a BOOTP Server

Reader/Writer through operation. 8-1

tartup Guide S On the Network Settings View, select the Obtain from BOOTP server Option

Use it for confirmation when you want to start to use the Reader/Writer. RF Tag

or the Fix at the IP address which is obtained from BOOTP server Option, and

If anything related to the Reader/Writer is not clear, refer to the Instruction V780-A-JIME-Z3BLI-10*1 (recommended)

then click the Set Button.

Sheet or User’s Manual. Host device Computer to monitor the

(e.g., PLC) results of communications diagnosis

OMRON Corporation

Always read the Terms and Conditions Agreement and Precautions for Correct Use in the User’s Manual

24-VDC power supply

before you attempt to use the Reader/Writer. ©OMRON Corporation 2017 All Rights Reserved.

(output current: 0.5 A min.)

Meanings of Symbols Indicates reference sections to the

Indicates references to

V780-series Reader/Writer User’s

more detailed information in

Switching Hub

Manual (Cat. No. Z389-E1).

this document. Recommended: W4S1-05C (made by OMRON)

Power Supply Cable Recommended: XS5F-D42@-@80-F

Introduction Installing the System STEP (made by OMRON)

Ethernet Cable

Confirm that you received all of the accessories.

Reader/Writer (V780-HMD68-ETN-@@) 4-1-1

Ethernet Cable Ethernet Cable Recommended: XS5W-T42@-@ME-K (made by OMRON)

 Front Mounting

*1. This is the model number for one package of 10 RF Tags.

Install the Reader/Writer with four M6 bolts. Use both spring washers and flat washers

Order the number of packages that you require.

(Recommended tightening torque: 4.3 N·m, M6 bolt mating length: 6 mm min.) 3. Paste the IP address memo label.

M6 bolt Mounting Hole Dimensions Write the set IP address on the IP address memo label and paste it on the

 Pin Assignments and Wire Colors of Recommended Power Supply

230±0.3 Four, M6 target reader/writer.

Spring washer

Cable (XS5F-D42@-@80-F)

Flat washer

Pin No. Name Wire color Description

24P Brown +24V Testing the Reader/Writer STEP

CONT White Control signal (operating mode signal)

Run Mode: Connect to +24 V and then start the RF Tag Access 5-9-1

(Unit: mm) Reader/Writer.

 Rear Mounting The following procedure uses communications commands to confirm that

Safe Mode: Connect to 0 V and then start the

Install the Reader/Writer with four M6 bolts. Use both spring washers and flat washers communications are possible with RF Tags and to check the communications time.

Reader/Writer.

1. Click the Utility Button on the left of the Web Browser Operation Window, and

(Recommended tightening torque: 4.3 N·m, M6 bolt mating length: 6 to 8 mm)

24N Blue 0V then click the RF Tag access Tab.

Mounting Hole Dimensions

M6 bolt 2. Select a command from the RF communication command List, and then

Black Reader/Writer and Accessories Not used.

Spring washer Four, 6.6 dia. enter the address, data size, and write data.

Flat washer 2. Turn ON the power supplies to the peripheral devices. 3. Click the Send Button.

Name Qty

4. The following procedure uses communications commands to confirm that communi-

Reader/Writer

cations are possible with RF Tags and to check the communications time.

Instruction Sheet Setting Up Communications STEP

Startup Guide (this document)

(Unit: mm) Set the IP address on the computer. 5-2-1

IP address label

Ferrite core *1 Set the IP address on the computer, but do not use the default IP address of the

RF Tags (V780-A-JIME-Z3BLI-10*1)

Reader/Writer given in the following table.

EU DECLARATION OF CONFORMITY *2

 Mounting on Non-metallic Material This example changes the last part of the IP address to a value other than 200

*1. A ferrite core is packaged with Model V780-HMD68-ETN-EU/-IN/-RU.

1. Use two, M4 screws to mount the RF Tags from the marked side. (i.e., to 1 to 199 or 201 to 254). Values of 0 and 255 cannot be used.

*2. A EU DECLARATION OF CONFORMITY is packaged with Model V780-HMD68-ETN-EU.

The V780-A-TA-133-10*1 Attachment is not necessary. (Recommended 0.

 Default IP Address Settings of the Reader/Writer

tightening torque: 1.2 N·m, M4 screw mating length: 4 mm min.)

Setting item Default setting

Operational Flow from Installation through Operation

M4 screw Mounting Hole Dimensions

IP address 192.168.1.200 (fixed setting)

Preparations Subnet mask 255.255.255.0 (fixed setting)

Install the Reader/Writer and RF Tags. (Unit: mm)

Marked side Default gateway 192.168.1.254 (fixed setting)

Install the system.

STEP 1

 Mounting on Metallic Material (RF Tag and Attachment) 1. Mount the RF Tag in the Attachment.

Wire the Reader/Writer to Use two M4 screws and tighten the nuts from the marked side of the RF Tag. Set the IP address of the Reader/Writer.

Connect the system. the peripheral devices. (Recommended tightening torque: 1.2 N·m)

RF Tag Scanning 5-9-2

1. Start the Web browser.

Marked side

STEP 2 Enter the IP address of the Reader/Writer in the address field of the Web Use the following procedure to see if there is an RF Tag in the communications

M4 screw

V780-A-JIME-Z3BLI-10*1 browser to display the Browser Operation Window. field of the Reader/Writer.

Enter http://192.168.1.200 if you are using the default URL. 1. Click the Utility Button on the left of the Web Browser Operation Window, and

Preparations

then click the RF Tag scan Tab.

for Communications Set the communications

2. Click the Start Button at the bottom right of the window.

conditions in the Reader/Writer. 3. The UII(EPC codes), numbers of communications, and reception levels will be

Set up communications. Screw mounting V780-A-TA-133-10*1

displayed in order as RF Tags are detected.

STEP 3

* Remove any RF Tags you do not want to communicate with from the communications field.

2. Mount the Attachment to which the RF Tag is mounted to the metallic material. Mount it with two M4 bolts.

Trail Operation Confirm that the host device and (Recommended tightening torque: 1.2 N·m, M6 bolt mating length: 4 mm min.)

Reader/Writer are connected Bolt

Mounting Hole Dimensions

Test the Reader/Writer. correctly and check communica-

tions with the RF Tags. (Unit: mm)

STEP 4

V780-A-JIME-Z3BLI-10*1

Onsite Confirmations

Check the ambient environment of the Reader/Writer on your site.

Check the ambient environment. V780-A-TA-133-10*1

Bolt mounting

STEP 5

Test communications with RF *1. This is the model number for one package of 10 RF Tags. Tags on your site. Order the number of packages that you require.

Test RF Tag communications.

STEP 6

Page Summary Contents For OMRON PLC Mechanical Controller IPC Multi-Axis Controller Touch Panel UHF with RFID System V780 Series V780-HMD68-ETN-[][]UHF RFID System Reader Writer Instruction Sheet

Page 1 2. Set the IP address of the Reader/Writer. Connecting the System STEP Click the Network settings Button on the left of the Web Browser Operation UHF RFID System 4-22 Window and select one of the foll...
Page 2 Reception Level Monitor 6-9-3 Communications Diagnostics 6-7-3 Focus Monitor Checking the Ambient Environment STEP 6-9-5 You can use the following procedures to display the reception level from one or...

Manual Details