# A B C D E F G H I J K L M N O P Q R S T U V W X Y Z

OMRON Pattern Matching Sensor F10 F10-C20 C25 C30 C35 C50 C55 Pattern Matching Sensor Amplifier Instruction Sheet

Summary

This comprehensive instruction sheet details the installation, operation, and maintenance of OMRON Pattern Matching Sensor Amplifiers. Designed for professionals in industrial automation, this guide covers detailed setup procedures, required safety precautions, optimal environmental limits (temperature and humidity), and wiring practices. It ensures users can properly integrate and maximize the performance of their sophisticated sensing systems.

📄 Preview PAGE OF 34

Page 1 Text Content

形F10-C20/C25/C30/C35/C50/C55 02.11.19 10:12 AM ページ a

Model F10-C20/C25

Model F10-C30/C35

Model F10-C50/C55

PATTERN MATCHING SENSOR AMPLIFIER

INSTRUCTION SHEET Thank you for selecting OMRON product. This sheet primarily describes precautions required in installing and operating the product. Before operating the product, read the sheet thoroughly to acquire sufficient knowledge of the product. For your convenience, keep the sheet at your disposal.

©OMRON Corporation     All Rights Reserved.

Page Summary Contents For OMRON Pattern Matching Sensor F10 F10-C20 C25 C30 C35 C50 C55 Pattern Matching Sensor Amplifier Instruction Sheet

Page 1 形F10-C20/C25/C30/C35/C50/C55 02.11.19 10:12 AM ページ a Model F10-C20/C25 Model F10-C30/C35 Model F10-C50/C55 PATTERN MATCHING SENSOR AMPLIFIER INSTRUCTION SHEET Thank you for selecting OMRON product. Th...
Page 2 形F10-C20/C25/C30/C35/C50/C55 02.11.19 10:12 AM ページ b In the place where the operating ambient humidity is not between PRECAUTIONS IN USING THE PRODUCT -35 and 85 % RH. In the place where corrosive gas...
Page 3 形F10-C20/C25/C30/C35/C50/C55 02.11.19 10:12 AM ページ d forced-air cooling fan or the air-conditioner to keep the Table of Contents temperature under 50 ℃. 1. Specifications/Functions ……………………………1 3. Noi...
Page 4 形F10-C20/C25/C30/C35/C50/C55 02.11.19 10:12 AM ページ 1 1. Specifications/Functions ●General Specifications Item F10-C20 / C25 / C30 / C35 / C50 / C55 Head interface (1 channel) Available Head : F10-S30R...
Page 5 形F10-C20/C25/C30/C35/C50/C55 02.11.19 10:12 AM ページ 3 ・External Input Specifications 2. Components Item NPN open collector output type PNP open collector output type Input is ON Short circuited to 0 V ...
Page 6 形F10-C20/C25/C30/C35/C50/C55 02.11.19 10:12 AM ページ 5 Displays measurement values (degree of conformity with the registered model). ON :Lit OFF:Not lit Displays the threshold.3 Level Result Indicators ...
Page 7 形F10-C20/C25/C30/C35/C50/C55 02.11.19 10:12 AM ページ 7 DIP Switch9 ● Changing Measurement Items PATT A.T.ON WD TMR LINE≠ PATT・PLN Automat cally switches between PATT/BANK pattern measurement and plain A...
Page 8 形F10-C20/C25/C30/C35/C50/C55 02.11.19 10:12 AM ページ 9 A.T.ON TMR LINE≠WD A.T.ON TMR LINE≠WD All the DIP switch pins are set to OFF All the DIP switch pins are set to OFF at the factory. at the factor...
Page 9 形F10-C20/C25/C30/C35/C50/C55 02.11.19 10:12 AM ページ 11 3. I/O Circuit Diagram F10-C25 PNP Models There are gray, green, and red input lines, but they are not used with this model. Take steps to ensure ...
Page 10 形F10-C20/C25/C30/C35/C50/C55 02.11.19 10:12 AM ページ 13 F10-C30/C50 NPN Models F10-C30/C50 PNP Models Brown(Vcc) Brown(Vcc) Level in- dicators Load Level in- Black (8-level Load dicators Yellow S_TEACH ...
Page 11 形F10-C20/C25/C30/C35/C50/C55 02.11.19 10:12 AM ページ 15 4. Connection of Serial Communication ●I/O Signals Signal Function You can input the measurement trigger and output the measurement OUTPUT Control...
Page 12 形F10-C20/C25/C30/C35/C50/C55 02.11.19 10:12 AM ページ 17 ●Multidrop Connections A maximum of 31 F10-C50/C55 Sensors can communicate with an IBM ・F10-VR2 PC/AT or compatible by connecting though RS-232C/4...
Page 13 形F10-C20/C25/C30/C35/C50/C55 02.11.19 10:12 AM ページ 19 5. Setting Procedure Press the teach/display button after locating the sensing object in the sensing area. Measurement Items: PATT/BANK5.1 TEACH M...
Page 14 形F10-C20/C25/C30/C35/C50/C55 02.11.19 10:12 AM ページ 21 Measurement Item: PATT/PLN Whether measurement is patterned or plain is determined automatically by comparing the contrast with the background wit...
Page 15 形F10-C20/C25/C30/C35/C50/C55 02.11.19 10:12 AM ページ 23 Change of Plain Measurement Detection Range Selection Mode 5.2 MONITOR Mode *Detection range at Plain Measurement Detection range at Plain Measure...
Page 16 形F10-C20/C25/C30/C35/C50/C55 02.11.19 10:12 AM ページ 25 Plain Measurement Press the UP/DOWN selection buttons to adjust the threshold. Adjust the threshold to the most suitable level Press the teach/dis...
Page 17 形F10-C20/C25/C30/C35/C50/C55 02.11.19 10:12 AM ページ 27 CONT Mode 5.3 RUN Mode In CONT mode, the Sensor is in sensing operation repeatedly while the CONT signal is ON. The measurement result is renewed ...
Page 18 形F10-C20/C25/C30/C35/C50/C55 02.11.19 10:12 AM ページ 29 Bank Change Input You can set the guide light to always ON to turn ON the Please input the number of BANK to "BANK 1 to 3" input lines. ...
Page 19 形F10-C20/C25/C30/C35/C50/C55 02.11.19 10:12 AM ページ 31 ●Moving Object Teaching(M_TEACH) 6. External Teaching in RUN Mode Min 50ms In RUN mode, a model can be registered by external signal input M_TEACH...
Page 20 形F10-C20/C25/C30/C35/C50/C55 02.11.19 10:12 AM ページ 33 7. Sysem setting 7.2 Unit Number setting (only F10-C50/C55) 1. Set the mode selector to TEACH, before turning on the power supply. 7.1 Off-delay t...
Page 21 形F10-C20/C25/C30/C35/C50/C55 02.11.19 10:12 AM ページ 35 7.3 Serial Communicationユ Baud Rate setting 7.4 Mode Change Plain Measuement Process    (only F10-C50/C55) 1. Change the Mode selector to TEACH, w...
Page 22 形F10-C20/C25/C30/C35/C50/C55 02.11.19 10:12 AM ページ 37 8. Serial Communication Command (only F10-C50/C55) 8.2 Output Response Format ■ Normal Response 8.1 Basic Input Format When the input command has ...
Page 23 形F10-C20/C25/C30/C35/C50/C55 02.11.19 10:12 AM ページ 39 8.3 List of Input Commands 8.4 Command Reference ■ Specifying F10 Operation Command formats are explained below in alphabetical order. The followi...
Page 24 形F10-C20/C25/C30/C35/C50/C55 02.11.19 10:12 AM ページ 41 Set the following numerical values for <bank_number>. When this command is recognized, a READY response will be returned. After verifying th...
Page 25 形F10-C20/C25/C30/C35/C50/C55 02.11.19 10:12 AM ページ 43 Example Set the following numerical values for <type> To transfer all bank data from Unit 6 to the host: Type Content Input :@06BS_AL[CR] Co...
Page 26 形F10-C20/C25/C30/C35/C50/C55 02.11.19 10:12 AM ページ 45 Set the following numerical values for <unit_number>. Input Command @<unit_number>MC_<parameter>[CR] Unit No. Content Set the va...
Page 27 形F10-C20/C25/C30/C35/C50/C55 02.11.19 10:12 AM ページ 47 Set the following numerical values for <parameter>. Unit No. Content <parameter> can be omitted. If omitted, the value defaults to 1 0...
Page 28 形F10-C20/C25/C30/C35/C50/C55 02.11.19 10:12 AM ページ 49 <comparison_result><contrast><average_density>[CR] ・When a measurement is performed once only and no result is :Plain measuremen...
Page 29 形F10-C20/C25/C30/C35/C50/C55 02.11.19 10:12 AM ページ 51 Input: @27ME_4_1[CR] Example Output: @27ME_READY[CR] To acquire the measurement mode of Unit 26: (Measurement performed on image in memory) Input:...
Page 30 形F10-C20/C25/C30/C35/C50/C55 02.11.19 10:12 AM ページ 53 Example SG -System data Get- : Acquire system data Parameter Content Value Meaning Unit number 01 to 31 Unit number SG acquires system data inform...
Page 31 形F10-C20/C25/C30/C35/C50/C55 02.11.19 10:12 AM ページ 55 number for <parameter> cannot be specified. @<unit_number>SS_ER[CR] : Not executed correctly Normal/Wide Content Set in Normal Mode Se...
Page 32 形F10-C20/C25/C30/C35/C50/C55 02.11.19 10:12 AM ページ 57 ・Moving Object Teaching performs the same action as teaching via an 9. Trouble Shooting external signal line. After this command has been recogniz...
Page 33 形F10-C20/C25/C30/C35/C50/C55 02.11.19 10:12 AM ページ 59 10. Dimensions Problem Probable cause Remedy All the LED of Teaching data setting er- Perform the teaching the threshold ror of the Sensor in indi...
Page 34 形F10-C20/C25/C30/C35/C50/C55 02.11.19 10:12 AM ページ 61 Note : Specifications subject to change without notice. 8P IN IR LA TO F1 0- 2: LU F1 0- 4: TY OMRON Corporation

Manual Details

Brand Omron
Pages 34
File Size 436.72 KB
Published June 05, 2026
80 views

Enter the captcha to get the download link:

captcha

Frequently Asked Questions

What is the recommended operating temperature range for the Amplifier?

The operating ambient temperature range is between 0 ℃ and 50 ℃.

How should I mount the Amplifier on a DIN Track?

Enlarge part A, then push the Amplifier in direction B. Remember that heat must dissipate properly when multiple units are installed side-by-side (minimum 5 mm space).

What precautions should I take regarding power lines and the Sensor cabling?

Do not wire high-tension lines alongside sensor lines; keep them separated or within a shielded conduit to prevent induction damage.

Are there special considerations for mounting when higher safety levels are required?

For equipment requiring high safety (nuclear, rail, medical, etc.), install the Amplifier directly using the flat washer and ensure proper tightening torque (no greater than 1.2 N·m).

What should I do if my operating temperature approaches 50 °C?

Use forced-air cooling or air-conditioning to keep the temperature well under 50 ℃.