Hanna pH 209 209R Bench Top pH Meters User Manual and Specifications

Summary

The PH 209 is a versatile bench-top pH meter designed for accurate measurement of acidity (pH), millivolts (mV), ORP, and temperature across diverse industrial and laboratory applications. This comprehensive manual provides step-by-step instructions on setup, calibration methods, proper electrode conditioning, advanced usage guides, and detailed technical specifications. It is essential reading for lab technicians and professionals who require reliable, accurate pH monitoring solutions.

📄 Preview PAGE OF 13

Page 1 Text Content

Instruction Manual

Bench Top p H Meters

Page Summary Contents For Hanna pH 209 209R Bench Top pH Meters User Manual and Specifications

Page 1 Instruction Manual Bench Top p H Meters
Page 2 Dear Customer, PRELIMINARY EXAMINATION Thank you for choosing a Hanna Instruments Product. Remove the instrument from the packing material and examine it Please read this instruction manual carefully ...
Page 3 FUNCTIONAL DESCRIPTION SPECIFICATIONS Range 0.00 to 14.00 p H Resolution 0.01 p H / 1 m V Accuracy (@20°C) ±0.01 p H / ±1 m V Typical EMC Deviation ±0.03 p H / ±2 m V p H Calibration Manual, 2 point, ...
Page 4 4 cm (1½ OPERATIONAL GUIDE Press the p H key to display the p H measurement. Power connection Plug the supplied 12 Vdc adapter into the power supply socket (#9 The display shows the p H value of the t...
Page 5 Note the temperature of the buffer solution using p H CALIBRATION a Checktemp C or a glass thermometer (e.g.20°C). IMPORTANT The instrument's p H range should be re-calibrated: Press the °C key to sel...
Page 6 p H VALUES AT VARIOUS TEMPERATURES ELECTRODE CONDITIONING AND MAINTENANCE Temperature has an effect on p H. The calibration buffer solutions are Note: to prevent damage to the electrode, remove the p ...
Page 7 For refillable electrodes: Follow the Storage Procedure above. If the filling solution (electrolyte) is more than 2½ cm (1") below the CLEANING PROCEDURE fill hole, add HI 7082 3.5M KCl electroly...
Page 8 TEMPERATURE-RESISTANCE CORRELATION ACCESSORIES FOR HANNA p H SENSITIVE GLASS p H CALIBRATION SOLUTIONS The resistance of glass electrodes partially depends on the temperature. HI 70004P p H 4.01 buffe...
Page 9 ORP PRETREATMENT SOLUTIONS HI 1330B HI 7091L Reducing pretreatment solution, 500 m L Glass body, semimicro, single junction, refillable, combination p H HI 7092L Oxidizing pretreatment solution, 500 m...
Page 10 FC 100B HI 1413B PVDF body, double junction, refillable, combination p H electrode. Glass body, single junction, flat tip, Viscolene, non-refillable, combina- Use: general purpose for food industry. t...
Page 11 Extension cables for screw-type electrodes (screw to BNC ELECTRODE APPLICATION adapter) REFERENCE GUIDE HI 7855/1 Extension cable 1m (3.3') long HI 7855/3 Extension cable 3m (9.9') long Application El...
Page 12 WARRANTY CE DECLARATION OF CONFORMITY All Hanna Instruments meters are guaranteed for two years against defects in workmanship and materials when used for their intended purpose and maintained accordi...
Page 13 SALES AND TECHNICAL SERVICE CONTACTS Australia: Tel. (03) 9769.0666 • Fax (03) 9769.0699 China: Tel. (10) 88570068 • Fax (10) 88570060 Egypt: Tel. & Fax (02) 2758.683 Germany: Tel. (07851) 9129-0 ...

Manual Details

Brand Bench
Pages 13
File Size 1.02 MB
Published May 16, 2026
65 views

Enter the captcha to get the download link:

captcha

Frequently Asked Questions

What safety precautions are necessary when handling the electrodes?

Avoid touching the glass bulb at all times due to electrostatic discharge, and wear ESD wrist straps during calibration.

Can this meter measure parameters besides pH?

Yes, it can also measure ion concentration (ISE) and ORP (Oxidation Reduction Potential).

What is the required storage/connection spot for the electrodes?

When measuring different samples consecutively, connect the electrode's BNC to socket #10.

Which model features an analog output capability?

The pH209R model has a recorder output feature and provides an analog output of 0 to 5V.

How should I prepare the electrode between test solutions?

It is recommended that you thoroughly rinse the electrode with the next solution to be measured.