# A B C D E F G H I J K L M N O P Q R S T U V W X Y Z

Hanna HI 2210/11 Microprocessor-based pH/mV/°C Bench Meters Instruction Manual

Summary

These advanced bench meters provide accurate, microprocessor-based measurements of pH, mV, and temperature, with upgraded models offering ion concentration (ISE) and ORP capabilities. This comprehensive manual is designed for laboratory technicians and scientific users who require precise water quality analysis. It offers step-by-step guides on everything from initial setup and calibration to complex electrode maintenance and troubleshooting. Use this resource to ensure optimal performance and maximize the longevity of your pH measurement equipment.

📄 Preview PAGE OF 15

Page 1 Text Content

Instruction Manual

HI 2210 HI 2211 Microprocessor-based p H/m V/°C Bench Meters

www.hannainst .com

Page Summary Contents For Hanna HI 2210/11 Microprocessor-based pH/mV/°C Bench Meters Instruction Manual

Page 1 Instruction Manual HI 2210 HI 2211 Microprocessor-based p H/m V/°C Bench Meters www.hannainst .com
Page 2 Dear Customer, WARRANTY Thank you for choosing a Hanna Instruments product. Please read this instruction manual carefully before using the instruments. HI 2210 and HI 2211 are guaranteed for two years...
Page 3 PRELIMINARY EXAMINATION FUNCTIONAL DESCRIPTION Remove the instrument from the packing material and examine it carefully to make sure that no damage has occurred during shipping. Front Panel If there i...
Page 4 SPECIF ICATIONS OPERATIONAL GUIDE POWER CONNECTION Plug the 12 VDC adapter into the power supply socket. Hp00.61ot00.2– Notes: These instruments use non volatile memory to retain the )ylno1122IH(Vm9.9...
Page 5 If measurements are taken successively in different samples, it is TEMPERATURE MEASUREMENTS recommended to rinse the electrode thoroughly with deionized water Connect the HI 7662 temperature probe to ...
Page 6 When the reading is stable and close to the selected buffer, p H CALIBRATION “READY” message will appear and “CFM” message will blink. Calibrate the instrument often, especially if high accuracy is re...
Page 7 Press RANGE to display the tem- TEMPERATURE CALIBRATION perature reading on the LCD during (for te chn ca personne on ly calibration (HI 2211 only). ONE-POINT CALIBRATION All the instruments are facto...
Page 8 Immerse the temperature probe in the second vessel as near as p H BUFFER TEMPERATURE possible to the reference thermometer. Allow a few seconds for the probe to stabilize. Use the ARROW keys to set th...
Page 9 For refillable electrodes: ELECTRODE CONDITIONING & MAINTENANCE If the filling solution (electrolyte) is more than 2½ cm (1") below the fill hole, add HI 7082 or HI 8082 3.5M KCl Electrolyte ...
Page 10 CLEANING PROCEDURE TROUBLESHOOTING GUIDE • General Soak in Hanna HI 7061 or HI 8061 General Cleaning Solution for approximately ½ hour. SMOTPMYS MELBORP NOITULOS • Protein Soak in Hanna HI 7073 or HI ...
Page 11 TEMPERATURE CORRELATION ACCESSORIES FOR p H SENSITIVE GLASS p H BUFFER SOLUTIONS The resistance of glass electrodes partially depends on the temperature. HI 70004P p H 4.01 Buffer Sachets, 20 m L, 25 ...
Page 12 ORP PRETREATMENT SOLUTIONS HI 1330B HI 7091L Reducing Pretreatment Solution, 460 m L bottle Glass-body, semimicro, single junction, refillable, combination p H HI 7092L Oxidizing Pretreatment Solution...
Page 13 FC 100B HI 1413B Plastic-body (PVDF), double junction, refillable, combination p H Glass-body, single junction, flat tip, Viscolene, non-refillable, combination electrode. Use: general purpose for foo...
Page 14 EXTENSION CABLE FOR SCREW-TYPE ELECTRODES RECOMMENDATIONS FOR USERS (SCREW TO BNC ADAPTER) Before using these products, make sure they are entirely suitable for HI 7855/1 Extension cable 1 m (3.3') lo...
Page 15 SALES AND TECHNICAL SERVICE CONTACTS Australia: Tel. (03) 9769.0666 • Fax (03) 9769.0699 China: Tel. (10) 88570068 • Fax (10) 88570060 Egypt: Tel. & Fax (02) 2758.683 Germany: Tel. (07851) 9129-0 ...

Manual Details

Brand Bench
Pages 15
File Size 653.11 KB
Published May 16, 2026
58 views

Enter the captcha to get the download link:

captcha

Frequently Asked Questions

What are the included accessories for the meter?

The kit includes an Electrode, Temperature Probe (HI 7662), Electrode Holder (HI 76404), pH 4.01 & 7.01 Buffers, Electrolyte Solution, a 12VDC Power Adapter, and the manual.

Can I use this meter for more than just pH?

The HI 2211 model can also measure Ion Concentration (ISE) and Oxidation Reduction Potential (ORP).

What safety precautions should I take when using the electrode?

Wear ESD wrist straps during operation to avoid damage from electrostatic discharges. Also, do not perform measurements in microwave ovens.

How is the instrument warranted?

The HI 2210 and HI 2211 are guaranteed for two years against defects in workmanship and materials.