The Expert Series Thermal Imager is an articulating handheld radiometer designed for professional thermal imaging. This guide provides essential instrument security procedures covering all aspects of data protection and memory management for TiX models. Learn how to safely handle, delete, and sanitize both internal eMMC storage and removable media (SD/USB). Essential reading for technicians who require strict data integrity and secure handling protocols for sensitive operational images.

📄 Preview 📖 Table of Contents Contents PAGE OF 1

Page 1 Text Content

Instrument Security Procedures

Model: Ti X500, Ti X501, Ti X520, Ti X560, Ti X580

Product Name: Expert Series Thermal Imager

Instrument Description: Articulating Handheld thermal imaging radiometer

Memory Description: This device family has numerous internal non-volatile memory devices for holding firmware, configuration files, startup splash screen, calibration coefficients, factory settings, and user interface settings. Image data may be stored on a removable micro SD card, USB flash drive, or embedded multimedia card (e MMC) device.

Memory Cleaning Instructions: The removable image memory devices can be cleaned by deleting the images from the device using the camera user interface or by ejecting the device and using a PC to access and delete the stored images. Note that the removable memory devices are not sanitized by these procedures. Data may still be recoverable by various data recovery methods. Numerous third party tools are available that may be used to permanently wipe the data from the memory device. Images stored on the internal e MMC device can be deleted through the user interface or through the USB and Wi-Fi interfaces. The camera firmware does not sanitize the internal memory after deletion or provide a method to do so.

Ti X500, Ti X520, Ti X560, Ti X580 SOMV 1 of 1 1/21/2022

Page Summary Contents For Fluke TiX560 Infrared Camera TiX500, TiX501, TiX520, TiX560, TiX580 Memory Volatility Statement

Page 1 Instrument Security Procedures Model: Ti X500, Ti X501, Ti X520, Ti X560, Ti X580 Product Name: Expert Series Thermal Imager Instrument Description: Articulating Handheld thermal imaging radiometer Me...

Manual Details

Brand Fluke
Pages 1
File Size 93.41 KB
Published June 05, 2026
14 views

Enter the captcha to get the download link:

captcha

Frequently Asked Questions

How is data stored on the Expert Series Thermal Imager?

Image data can be stored on a removable micro SD card, USB flash drive, or embedded multimedia card (eMMC).

How do I remove stored image data from external memory?

You can delete images using the camera user interface or by accessing and deleting them via a PC after ejecting the device.

Are the removable memory devices sanitized when deleting data?

No, removing data does not sanitize these memory devices, and data may still be recoverable through various methods. Third-party tools are needed for permanent wiping.

How can I wipe/delete internal eMMC images on the device?

Internal eMMC images can be deleted either through the user interface or through the USB and Wi-Fi interfaces.