# A B C D E F G H I J K L M N O P Q R S T U V W X Y Z

Rockwell Automation 1769-IM12 Installation User's Manual and Instructions

Summary

The Compact 240V AC Input Module is a critical component designed for expanding industrial control systems via reliable electrical inputs. This comprehensive manual guides users through every phase of implementation, covering detailed installation procedures, system assembly, field wiring connections, and safe module replacement. It also provides vital technical documentation, including I/O memory mapping, specifications, and essential hazardous location protocols. Ideal for automation engineers, technicians, and industrial integrators who require precise guidance to properly install, expand, and maintain their high-performance programmable logic control systems.

📄 Preview 📖 Table of Contents Contents PAGE OF 16

Page 1 Text Content

Compact™ 240V ac Input Module

(Catalog Number 1769-IM12)

Installation Instructions

Inside Module Description ...................................................................2 Module Installation ....................................................................3 System Assembly......................................................................4 Mounting Expansion I/O............................................................5 Replacing a Single Module within a System .............................7 Field Wiring Connections ..........................................................7 I/O Memory Mapping...............................................................10 Spare/Replacement Parts .......................................................10 Specifications.......................................................................... Hazardous Location Considerations .......................................14 Environnements dangereux ....................................................14 For More Information...............................................................15

Publication 1769-IN011B-EN-P

Page Summary Contents For Rockwell Automation 1769-IM12 Installation User's Manual and Instructions

Page 1 Compact™ 240V ac Input Module (Catalog Number 1769-IM12) Installation Instructions Inside Module Description ...................................................................2 Module Installation .....
Page 2 Compact™ 240V ac Input Module Module Description Description bus lever (with locking function) 2a upper panel mounting tab 2b lower panel mounting tab DANGER Do Not Remove RTB Under Power Unless Area ...
Page 3 Compact™ 240V ac Input Module Module Installation Compact I/O is suitable for use in an industrial environment when installed in accordance with these instructions. Specifically, this equipment is int...
Page 4 Compact™ 240V ac Input Module System Assembly The module can be attached to the controller or an adjacent I/O module before or after mounting. For mounting instructions, see “Panel Mounting” on page 5...
Page 5 Compact™ 240V ac Input Module Mounting Expansion I/O ATTENTION: During panel or DIN rail mounting of all devices, be sure that all debris (metal chips, wire strands, etc.) is kept from falling into th...
Page 6 Compact™ 240V ac Input Module Panel Mounting Procedure Using Modules as a Template The following procedure allows you to use the assembled modules as a template for drilling holes in the panel. If you...
Page 7 Compact™ 240V ac Input Module Replacing a Single Module within a System The module can be replaced while the system is mounted to a panel (or DIN rail). 1. Remove power. See important note on page 3. ...
Page 8 Compact™ 240V ac Input Module Input Wiring Basic wiring1 of input devices to the 1769-IM12 is shown below. ATTENTION: Be careful when stripping wires. Wire fragments that fall into a module could caus...
Page 9 Compact™ 240V ac Input Module upper retaining wiring the finger-safe terminal block lower retaining Removing the Finger-Safe Terminal Block To remove the terminal block, loosen the upper and lower ret...
Page 10 Compact™ 240V ac Input Module Wire Size and Terminal Screw Torque Each terminal accepts up to two wires with the following restrictions: Terminal Screw Retaining Screw Wire Type Wire Size Torque Torqu...
Page 11 Compact™ 240V ac Input Module Specifications General Specifications Specification Value 118 mm (height) x 87 mm (depth) x 35 mm (width) height including mounting tabs is 138 mm Dimensions 4.65 in. (he...
Page 12 Compact™ 240V ac Input Module Input Specifications Specification 1769-IM12 Voltage Category 200/240V ac Operating Voltage Range 159V ac to 265V ac at 47 Hz to 63 Hz Number of Inputs Bus Current Draw (...
Page 13 Compact™ 240V ac Input Module Temperature Derating Ma xim um Nu mb er of Po int s ( Pts ) O The following graph shows the number of points that can be ON at various ambient temperatures. 1769-IM12 Poi...
Page 14 Compact™ 240V ac Input Module Hazardous Location Considerations This equipment is suitable for use in Class I, Division 2, Groups A, B, C, D or non-hazardous locations only. The following ATTENTION st...
Page 15 Compact™ 240V ac Input Module For More Information For Refer to this Document Pub. No. A more detailed description of how Micro Logix 1200 and to install and use your Compact I/O Micro Logix 1500 1764...
Page 16 Compact and Micro Logix are trademarks of Rockwell Automation. Publication 1769-IN011B-EN-P - June 2000 PN 40071-096-01(B) Supercedes 1769-IN011A-EN-P - April 2000 & 1769-5.8 - January 1999 © 2000...

Manual Details

Brand Rockwell Automation
Pages 16
File Size 501.55 KB
Published June 05, 2026
45 views

Enter the captcha to get the download link:

captcha

Frequently Asked Questions

How do I prevent damage from static electricity when handling this module?

Touch a grounded object first, wear an approved wrist-strap grounding device, and avoid touching connector pins or circuit components.

What must be done before installing or removing the module?

You must disconnect all power. Removing or inserting the module while powered increases the risk of an electrical arc and potential injury.

How should I assemble multiple modules in a system?

First, disconnect power. Then, use the upper/lower tongue-and-groove slots to secure them and align the bus connectors properly.

Which controllers are compatible with this Input Module?

It is designed to work with MicroLogix 1200 and MicroLogix 1500 Programmable Controllers, and can use a DeviceNet Adapter.