Philips BT139X series 600V/800V triacs in SOT186A packages handling 16A RMS with 140A surge capability and high thermal cycling performance. Provides limiting values, isolation specs, gate parameters, and thermal resistance for motor control, lighting, heating, and static switching. For power engineers designing AC mains switching circuits.

📄 Preview PAGE OF 7

Page 1 Text Content

查询BT139X series供应商

Philips Semiconductors Product specification

Triacs BT139X series

GENERAL DESCRIPTION QUICK REFERENCE DATA Passivated triacs in full pack, plastic SYMBOL PARAMETER MAX. MAX. UNIT envelope, intended for use in applications requiring high bidirectional BT139X- transient and blocking voltage capability BT139X- 600F and high thermal cycling performance. BT139X- 600G

Typical applications include motor VDRM Repetitive peak off-state

control, industrial and domestic lighting, voltages

heating and static switching. IT(RMS) RMS on-state current

ITSM Non-repetitive peak on-state

current

PINNING - SOT186A PIN CONFIGURATION SYMBOL PIN DESCRIPTION

main terminal 1

main terminal 2 gate

case isolated

LIMITING VALUES Limiting values in accordance with the Absolute Maximum System (IEC 134). SYMBOL PARAMETER CONDITIONS MIN. MAX. UNIT

VDRM Repetitive peak off-state

voltages

IT(RMS) RMS on-state current full sine wave; Ths ≤ 38 ˚C ITSM Non-repetitive peak full sine wave; Tj = 25 ˚C prior to

on-state current surge

t = 20 ms t = 16.7 ms

I2t I2t for fusing t = 10 ms A2s d IT/dt Repetitive rate of rise of ITM = 20 A; IG = 0.2 A;

on-state current after d IG/dt = 0.2 A/µs triggering T2+ G+ A/µs

IGM Peak gate current VGM Peak gate voltage PGM Peak gate power PG(AV) Average gate power over any 20 ms period 0.5 Tstg Storage temperature -40 ˚C Tj Operating junction ˚C

temperature

1 Although not recommended, off-state voltages up to 800V may be applied without damage, but the triac may switch to the on-state. The rate of rise of current should not exceed 15 A/µs.

October 2001 Rev 1.400

Page Summary Contents For Philips Semiconductors BT139X series Data Handbook (1) User Manual

Page 1 查询BT139X series供应商 Philips Semiconductors Product specification Triacs BT139X series GENERAL DESCRIPTION QUICK REFERENCE DATA Passivated triacs in full pack, plastic SYMBOL PARAMETER MAX. MAX. UNIT en...
Page 2 Philips Semiconductors Product specification Triacs BT139X series ISOLATION LIMITING VALUE & CHARACTERISTIC Ths = 25 ˚C unless otherwise specified SYMBOL PARAMETER CONDITIONS MIN. TYP. MAX. UNIT V...
Page 3 Philips Semiconductors Product specification Triacs BT139X series DYNAMIC CHARACTERISTICS Tj = 25 ˚C unless otherwise stated SYMBOL PARAMETER CONDITIONS MIN. TYP. MAX. UNIT BT139X- ...F ...G d VD/dt C...
Page 4 Philips Semiconductors Product specification Triacs BT139X series Ptot / W Ths(max) / C IT(RMS) / A BT139X IT(RMS) / A Ths / C Fig.1. Maximum on-state dissipation, Ptot, versus rms Fig.4. Maximum perm...
Page 5 Philips Semiconductors Product specification Triacs BT139X series IGT(Tj) IT / A IGT(25 C) Tj = 125 C T2+ G+ Tj = 25 C typ max 2.5 Vo = 1.195 V T2- G- Rs = 0.018 Ohms T2- G+ Tj / C VT / V Fig.7. Norma...
Page 6 Philips Semiconductors Product specification Triacs BT139X series MECHANICAL DATA Dimensions in mm Net Mass: 2 g 10.3 max 4.6 max 3.0 2.9 max Recesses (2x) 0.8 max. depth 15.8 seating max max. max. pl...
Page 7 Philips Semiconductors Product specification Triacs BT139X series DEFINITIONS DATA SHEET STATUS DATA SHEET PRODUCT DEFINITIONS STATUS2 STATUS3 Objective data Development This data sheet contains data ...

Manual Details

Brand Philips
Pages 7
File Size 40.76 KB
Published July 04, 2026
4 views

Enter the captcha to get the download link:

captcha

Frequently Asked Questions

What is the maximum RMS on-state current of BT139X series triacs?

The maximum RMS on-state current is 16 A when the heatsink temperature is ≤ 38 ˚C.

Are BT139X series triacs suitable for life support applications?

No, they are not designed for life support applications; use in such cases is at the customer's own risk.

What is the RMS isolation voltage of BT139X series triacs?

The RMS isolation voltage from all three terminals to the external heatsink is up to 2500 V.

What are typical applications of BT139X series triacs?

Typical applications include motor control, industrial and domestic lighting, heating and static switching.