Page 1
Instructions Upper Arm Blood Pressure Model EW3153 For questions or assistance with your blood pressure monitor, call us at 1-800-338-0552. Panasonic Consumer Electronics Company Division of Panasonic...
Page 2
Panasonic Oscillometric Diagnostec™ Automatic Arm Blood Pressure Table of Contents Monitor Model EW3153 is a device intended to measure systolic and Introduction .........................................
Page 3
Panasonic Oscillometric Diagnostec™ Automatic Arm Blood Pressure Table of Contents Monitor Model EW3153 is a device intended to measure systolic and Introduction .........................................
Page 4
Introduction Important Instructions Before Use Thank you for purchasing the Panasonic Automatic Arm Blood Pressure 1. Do not confuse self-monitoring with self-diagnosis. Blood pressure Monitor EW3153....
Page 5
Introduction Important Instructions Before Use Thank you for purchasing the Panasonic Automatic Arm Blood Pressure 1. Do not confuse self-monitoring with self-diagnosis. Blood pressure Monitor EW3153....
Page 6
30 minutes prior to taking your blood pressure. Precautions to Ensure Safe, Reliable Operation Blood pressure will be higher than usual: - when you are excited or tense 1. Do not drop the unit. Protec...
Page 7
30 minutes prior to taking your blood pressure. Precautions to Ensure Safe, Reliable Operation Blood pressure will be higher than usual: - when you are excited or tense 1. Do not drop the unit. Protec...
Page 8
or pinch it with objects. Do not wrap the cord around the main unit and Easily Check Your Blood Pressure Readings the AC adapter. Doing any of these things may result in the risk of fire or electric s...
Page 9
or pinch it with objects. Do not wrap the cord around the main unit and Easily Check Your Blood Pressure Readings the AC adapter. Doing any of these things may result in the risk of fire Against the J...
Page 10
Preparations Prior to Taking Measurements Parts Identification To use this product, the power supplies are required for both the Main unit main unit and the wireless display. Measuring section Main un...
Page 11
Preparations Prior to Taking Measurements Parts Identification To use this product, the power supplies are required for both the Main unit main unit and the wireless display. Measuring section Main un...
Page 12
Parts Identification (continued) When Using the Main Unit with Batteries Wireless display *Always use alkaline batteries. (4 AA-size Panasonic LR6 alkaline batteries) When replacing batteries, always ...
Page 13
Parts Identification (continued) When Using the Main Unit with Batteries Wireless display *Always use alkaline batteries. (4 AA-size Panasonic LR6 alkaline batteries) When replacing batteries, always ...
Page 14
Inserting the Batteries into the Wireless Display Setting the time and date *Always use alkaline batteries. (2 AA-size LR6 alkaline batteries) * Please be sure to set the date and time before taking t...
Page 15
Inserting the Batteries into the Wireless Display Setting the time and date *Always use alkaline batteries. (2 AA-size LR6 alkaline batteries) * Please be sure to set the date and time before taking t...
Page 16
Taking a Reading Place the wireless display in front of your body where you can see it easily. Advice: The main unit and the wireless display In general, blood pressure measurements are lower on the s...
Page 17
Taking a Reading Place the wireless display in front of your body where you can see it easily. Advice: The main unit and the wireless display In general, blood pressure measurements are lower on the s...
Page 18
Positions of the main unit and the wireless display Taking a Reading (continued) Your body reflects infrared Face the wireless display towards you Do not take measurements. rays. into position within ...
Page 19
Positions of the main unit and the wireless display Taking a Reading (continued) Your body reflects infrared Face the wireless display towards you Do not take measurements. rays. into position within ...
Page 20
Movement detection function Taking a Reading (continued) If movement is detected while measurement is being taken and more Measurement pressure is applied by the pressure cuff, the mark will be displa...
Page 21
Movement detection function Taking a Reading (continued) If movement is detected while measurement is being taken and more Measurement pressure is applied by the pressure cuff, the mark will be displa...
Page 22
Alarm function signals high blood pressure Taking a Reading (continued) Blood pressure values for both systolic and diastolic readings are Irregular pulse function determined and indicated via mark in...
Page 23
Alarm function signals high blood pressure Taking a Reading (continued) Blood pressure values for both systolic and diastolic readings are Irregular pulse function determined and indicated via mark in...
Page 24
Taking a Reading (continued) Storing and Calling up Blood Pressure Readings To interrupt measurements quickly Up to 90 readings each can be stored in the memory for two people. Press the Quick air rel...
Page 25
Taking a Reading (continued) Storing and Calling up Blood Pressure Readings To interrupt measurements quickly Up to 90 readings each can be stored in the memory for two people. Press the Quick air rel...
Page 26
Storing and Calling up Blood Pressure Readings (continued) Deleting all data stored in memory (1) Recall the user whom you want to delete using the user selection Calling up readings from memory butto...
Page 27
Storing and Calling up Blood Pressure Readings (continued) Deleting all data stored in memory (1) Recall the user whom you want to delete using the user selection Calling up readings from memory butto...
Page 28
Comparing AM and PM Average Systolic Blood Pressure After Use Average AM and PM systolic blood pressure is displayed in order to allow Tilt the main unit (using the you to compare readings from both t...
Page 29
Comparing AM and PM Average Systolic Blood Pressure After Use Average AM and PM systolic blood pressure is displayed in order to allow Tilt the main unit (using the you to compare readings from both t...
Page 30
Specifications Q & A Power source DC 6 V (Main unit: Four AA/LR6 size alkaline Why are the blood pressure values measured at home different batteries) from those measured at the doctor’s office? A...
Page 31
Specifications Q & A Power source DC 6 V (Main unit: Four AA/LR6 size alkaline Why are the blood pressure values measured at home different batteries) from those measured at the doctor’s office? A...
Page 32
Q & A (continued) Care and Maintenance Do not attempt to disassemble, repair or modify the unit. Since the mark was displayed, I retried the measurement Doing so may cause fire or cause the unit t...
Page 33
Q & A (continued) Care and Maintenance Do not attempt to disassemble, repair or modify the unit. Since the mark was displayed, I retried the measurement Doing so may cause fire or cause the unit t...
Page 34
Troubleshooting Symptom Possible cause Press the ring portion on the outside of the Display Status before error Cause and solution Pressure cuff comes off. pressure cuff into the main unit. (See page ...
Page 35
Troubleshooting Symptom Possible cause Press the ring portion on the outside of the Display Status before error Cause and solution Pressure cuff comes off. pressure cuff into the main unit. (See page ...
Page 36
Operating Instructions Instrucciones de Uso Upper Arm Blood Pressure Monitor Monitor de presión arterial de brazo Model No./Nº de Modelo EW3153 English For questions or assistance with your blood pres...