A comprehensive service guide for Pressurematic pneumatic and hydraulic high/low pressure pilots. This manual provides expert instructions on selecting the correct model and spring combination, detailing precise procedures for set point adjustments, range screw calibration, and reassembly. It is essential reading for maintenance technicians and engineers requiring proper field or bench servicing of these critical control devices.

📄 Preview PAGE OF 22

Page 1 Text Content

Service Manual I-0220 Rev. 4 January 2018

Pressurematic® Pneumatic or Hydraulic High/Low Pressure Pilots

Page Summary Contents For EMERSON Manuals Pressurematic® Pneumatic or Hydraulic High Low Pressure Pilots, Bettis-EN

Page 1 Service Manual I-0220 Rev. 4 January 2018 Pressurematic® Pneumatic or Hydraulic High/Low Pressure Pilots
Page 3 Servive Manual Table of Contents I-0220 Rev. 4 January 2018 Table of Contents Section 1: Model and Spring Selection 1.1 Scope .............................................................................
Page 4 Operation and Adjustments Service Manual January 2018 I-220 Rev. 4 Operation and Adjustments Operation and Adjustments
Page 5 Servive Manual Operation and Adjustments I-0220 Rev. 4 January 2018 Operation and Adjustments
Page 6 Operation and Adjustments Service Manual January 2018 I-220 Rev. 4 Operation and Adjustments
Page 7 Servive Manual Operation and Adjustments I-0220 Rev. 4 January 2018 Operation and Adjustments
Page 8 Section 1: Model and Spring Selection Service Manual January 2018 I-220 Rev. 4 Section 1: Model and Spring Selection 1.1 Scope This procedure describes the model and spring selection of Pressurematic ...
Page 9 Servive Manual Section 2: Adjustment Procedure I-0220 Rev. 4 January 2018 Section 2: Adjustment Procedure 2.1 Set Point Adjustment Field/bench Setpoint Verification Calibration Equipment: 1. N2 bottle...
Page 10 Section 2: Adjustment Procedure Service Manual January 2018 I-220 Rev. 4 2.2.3 For cases with high set point only Low Range Limit = (set point) – (maximum span) / 2 – 100 where "maximum span&quot...
Page 11 Servive Manual Section 3: Pressurematic Set Point Adjustment I-0220 Rev. 4 January 2018 Section 3: Pressurematic Set Point Adjustment Set point adjustment for Series 2000, 2200, 2400: NOTE: Refer to P...
Page 12 Section 3: Pressurematic Set Point Adjustment Service Manual January 2018 I-220 Rev. 4 3.2 Cases with low set point only a. Set high trip bolt fully away from the trip spring. b. Adjust the low set po...
Page 13 Servive Manual Section 4: Range Screw Adjustment I-0220 Rev. 4 January 2018 Section 4: Range Screw Adjustment This procedure describes the method of changing the range/span from the factory set range/...
Page 14 Section 4: Range Screw Adjustment Service Manual January 2018 I-220 Rev. 4 8. Remove trip spring lower washer (23) from the top of the piston (3). 9. Install range screw adjusting tool in range screw ...
Page 15 Servive Manual Section 4: Range Screw Adjustment I-0220 Rev. 4 January 2018 Range Screw Adjustment
Page 16 Section 5: Range Verification Procedure Service Manual January 2018 I-220 Rev. 4 Section 5: Range Verification Procedure Refer to calibration drawing APB0579. NOTE: Total piston travel range is approx...
Page 17 Servive Manual Section 6: Reassembly I-0220 Rev. 4 January 2018 Section 6: Reassembly 1. Re-install trip spring assembly (14) onto the piston with a washer on each side of the trip spring. 2. Install ...
Page 18 Section 7: Modifying Pressurematic Assembly Type Service Manual January 2018 I-220 Rev. 4 Section 7: Modifying Pressurematic Assembly Type Refer to drawings APB0570 and CB0066-10. NOTE: To prevent VAL...
Page 19 Servive Manual Section 7: Modifying Pressurematic Assembly Type I-0220 Rev. 4 January 2018 Modifying Pressurematic Assembly Type
Page 20 Section 7: Modifying Pressurematic Assembly Type Service Manual January 2018 I-220 Rev. 4 Modifying Pressurematic Assembly Type
Page 22 World Area Configuration Centers (WACC) offer sales support, service, inventory and commissioning to our global customers. Choose the WACC or sales office nearest you: NORTH & SOUTH AMERICA MIDDLE...

Manual Details

Brand Emerson
Pages 22
File Size 1.26 MB
Published June 05, 2026
50 views

Enter the captcha to get the download link:

captcha

Frequently Asked Questions

How do I select the correct model and spring combination?

Select a Pressurematic series and spring combination using data tabulated in the Range Table to meet requirements for range limits, span, and/or deadband. Use the largest piston and softest spring possible.

What is the goal of adjusting the range screw?

The objective is to center the adjusted span between the low and high range limits, or if only one set point exists, to center it between the range limits.

What tools are needed for Set Point Verification Calibration?

Calibration requires an N bottle, HP regulator, LP regulator, hose, block and bleed valve, and recommended test gauges (e.g., 0-150 psi or 0-1500 psi).

Can I modify the assembly type myself?

Yes, the service manual provides specific procedures for changing between P-AR to P-MR, and from P-MR back to P-AR.