# A B C D E F G H I J K L M N O P Q R S T U V W X Y Z

Dell EMC PowerEdge C6525 Technical Specifications Guide

Summary

The Dell EMC PowerEdge C6525 is a high-density server sled for data center environments. This technical specifications guide covers sled dimensions, chassis weight, processor specs, memory configurations, and expansion card guidelines. Target users are IT infrastructure planners, data center administrators, and system engineers deploying enterprise server solutions.

📄 Preview 📖 Table of Contents Contents PAGE OF 24

Page 1 Text Content

Dell EMC Power Edge C6525 Technical Specifications Guide

Regulatory Model: E63S Series Regulatory Type: E63S001 March 2022 Rev. A05

Page Summary Contents For Dell EMC PowerEdge C6525 Technical Specifications Guide

Page 1 Dell EMC Power Edge C6525 Technical Specifications Guide Regulatory Model: E63S Series Regulatory Type: E63S001 March 2022 Rev. A05
Page 2 Notes, cautions, and warnings NOTE: A NOTE indicates important information that helps you make better use of your product. CAUTION: A CAUTION indicates either potential damage to hardware or loss of d...
Page 3 Contents Chapter 1: Technical specifications............................................................................................... Sled dimensions ...............................................
Page 4 Technical specifications The technical and environmental specifications of your system are outlined in this section. Topics: Sled dimensions Chassis weight Processor specifications Supported operating...
Page 5 Chassis weight Table 2. Chassis weight with sleds System Maximum weight (with all sleds and drives) 12 x 3.5-inch configuration 45.53 kg (100.37 lb) 24 x 2.5-inch configuration 41.5 kg (91.49 lb) Syst...
Page 6 PCIe slot priority Table 4. Expansion card riser configurations Riser Slot 1 Slot 2 Length Height Primary Minimum Supported option processor processor configurations requirement Riser NA Half Length L...
Page 7 Table 6. Riser configurations: Riser 1A - Processor 1 and 2 (continued) Card type Slot priority Maximum number of cards LOM riser ; 10G (Broadcom/QLogic) (BASe T/SFP/SF+/SFP+) LOM riser ; 25G (QLogic/...
Page 8 Table 7. Riser configurations: Riser 1A + Riser 2A - Processor 2 (continued) Card type Slot priority Maximum number of cards ASSY,CRD,CTL,H750,ADPT,250MM (Broadcom) ASSY,CRD,CTL,H350,ADPT (Broadcom) A...
Page 9 Table 10. Supported drive options for the Power Edge C6525 sled Maximum number of drives in the Maximum number of drives assigned per sled sled 12 x 3.5-inch drive systems Three SAS or SATA hard drive...
Page 10 Table 12. Supported RAID options with M.2 SATA drives (continued) Options Single M.2 SATA drive without RAID Dual M.2 SATA drives with hardware Supported CPUs CPU 1 CPU 1 NOTE: RAID options are only s...
Page 11 Table 14. Standard operating temperature specifications Standard operating temperature Allowable Operation Temperature Ranges (For Altitude <900 5 to 40°C (41 to 104°F) with no direct sunlight on t...
Page 12 Table 15. Maximum continuous operating temperature for dual processor with 2.5-inch direct / 2.5-inch NVMe drive configuration - Air cooled (continued) CPU TDP Cores 24 x drives 16 x drives 8 x drives...
Page 13 Table 16. Maximum continuous operating temperature for dual processor with 3.5-inch Direct drive configuration - Air cooled (continued) CPU TDP Cores 12 x drives 8 x drives 4 x drives Not supported No...
Page 14 Table 17. Maximum continuous operating temperature for dual processor with 2.5-inch direct / 2.5-inch NVMe drive configuration - Liquid cooled (continued) CPU TDP Cores 24 x drives 16 x drives 8 x dri...
Page 15 Table 19. Maximum continuous operating temperature for single processor with 2.5-inch direct / 2.5-inch NVMe drive configuration - Air cooled CPU TDP Cores 24 x drives 16 x drives 8 x drives 4 x drive...
Page 16 Table 19. Maximum continuous operating temperature for single processor with 2.5-inch direct / 2.5-inch NVMe drive configuration - Air cooled (continued) CPU TDP Cores 24 x drives 16 x drives 8 x driv...
Page 17 Table 20. Maximum continuous operating temperature for single processor with 3.5-inch Direct drive configuration - Air cooled (continued) CPU TDP Cores 12 x drives 8 x drives 4 x drives Other thermal ...
Page 18 Table 21. Maximum continuous operating temperature for dual processor with 1x T4 GPU card for 2.5- inch direct / 2.5-inch NVMe drive configuration - Air cooled (continued) CPU TDP Cores 24 x drives 16...
Page 19 Table 22. Maximum continuous operating temperature for dual processor with 1x T4 GPU card for 2.5- inch direct / 2.5-inch NVMe drive configuration - Liquid cooled (continued) CPU TDP Cores 24 x drives...
Page 20 Table 23. Maximum continuous operating temperature for single processor with 1x T4 GPU card for 2.5-inch direct / 2.5-inch NVMe drive configuration - Air cooled (continued) CPU TDP Cores 24 x drives 1...
Page 21 Table 24. Maximum continuous operating temperature for dual processor with 128GB LRDIMM for 2.5- inch direct / 2.5-inch NVMe drive configuration - Air cooled (continued) CPU TDP Cores 24 x drives 16 x...
Page 22 Table 25. Maximum continuous operating temperature for dual processor with 128GB LRDIMM for 2.5- inch direct / 2.5-inch NVMe drive configuration - Liquid cooled (continued) CPU TDP Cores 24 x drives 1...
Page 23 Table 27. Particulate contamination specifications (continued) Particulate Specifications contamination Corrosive dust Air must be free of corrosive dust. Residual dust present in the air must have a ...
Page 24 Maximum altitude specifications Table 32. Maximum altitude specifications Maximum altitude Allowable Operation Maximum Temperature Gradient (applies 20°C in an hour* (36°F in an hour) and 5°C in 15 mi...

Manual Details

Brand Dell
Pages 24
File Size 294.39 KB
Published July 01, 2026
4 views

Enter the captcha to get the download link:

captcha

Frequently Asked Questions

What are the non-operational temperature limits for this system?

The non-operational temperature limit is from -40 to 65°C (-40 to 149'F).

Can I use this model with dual processor configurations?

No, it supports single processor configuration only and has no support for dual processor configuration.

Is NVMe SSD supported when operating in fresh air mode?

No; according to the Fresh Air Operation table, NVMe SSD is not supported.

What is the maximum operational altitude limit?

The Maximum Operational Altitude is 3,048 meters (10,000 feet).