This comprehensive manual provides technical guidance and required procedures for installing, assembling, and maintaining the SIRIUS Contactor (3RT6.2). It details critical information including wiring diagrams, mounting specifications, component dimensions, and step-by-step removal instructions. Designed for qualified electricians and electrical technicians, this resource ensures safe and correct integration of the contactor into industrial control systems, emphasizing compliance with detailed technical standards.

📄 Preview PAGE OF 5

Page 1 Text Content

SIRIUS

3RT6.2

Contactor S0 EN Original Operating Instructions

Hazardous voltage. Will cause death or serious injury.

EN DANGER Turn off and lock out all power supplying this device before working on this device. Installation and maintenance work on this device may only

be carried out by an authorized electrician.

EN Assembly 中文 安装

3RT6.2.-1 M4 1,2 ... 1,6 Nm (10.3 14.1 lb in) 3RT1926-4P

3RT1926-4P

EN Accessories 中文 附件

EN Assembly

3RT6.2

3RT6.2

3RH6911-1AA..

3RH6911-.HA..

Technical Hotline: Telephone: +86-400-810-4288 (8:30 - 17:15 UTC+8) Fax: ++86-10-6471-9991

E-mail: [email protected] Internet: www.4008104288.com.cn or www.ad.siemens.com.cn/service

A5E02960831A/RS-AB/004 Last update: 06 June 2017 3ZX1012-0RT62-1AA1

Page Summary Contents For Siemens Siemens Industrial SIRIUS Relays S0 SIRIUS Relay S0 User's Manual

Page 1 SIRIUS 3RT6.2 Contactor S0 EN Original Operating Instructions Hazardous voltage. Will cause death or serious injury. EN DANGER Turn off and lock out all power supplying this device before working on t...
Page 2 EN Removal 中文 拆卸 3RH6921-.DA. EN Assembly 中文 安装 3RH6921-.DA. 3RH6921-.DA. 3ZX1012-0RT62-1AA1
Page 3 NC/NO: max. Stck. pc. EN Removal 中文 拆卸 3RT6.2. 3RT6.2-.K 3RT6.2. Σ NC max. 3RT6926-1... EN Assembly 3RT6926-1... EN Removal 中文 拆卸 3ZX1012-0RT62-1AA1
Page 4 3RU6126-..0 3RU6126-..B0 EN Connect 中文 连接 3RT6.2.-1 (A1/A2, NO/NC) 3RT6.2.-1 (L1, L2, L3) 3RH6911-1 PZ 2:  (5 6 mm) PZ 2 ( 5 6 mm) M4: 2,0 2,5 Nm M3: 0,8 1,2 Nm (18 to lb.in) (7 to 10.3 lb.in) (1,0 ...
Page 5 EN Mounting position 中文 安装位置 3RT6.2.-.....-1... EN Dimension drawings (all dimensions in mm) 中文 尺寸图 ( 单位:mm) 3RT6.2.-1 (1) 3RH6921-1DA.. (2) 3RH6911-1HA.. 3RT6.2.-1 Subject to change without prior not...

Manual Details

Brand Siemens
Pages 5
File Size 1.76 MB
Published May 28, 2026
46 views

Enter the captcha to get the download link:

captcha

Frequently Asked Questions

What safety steps must I take before working on this device?

Danger voltage is present; you must turn off and lock out all power supplying the device, and only an authorized electrician should perform maintenance.

What torque should be used when mounting the device hardware?

For M4 screws, the recommended assembly torque range is 1.2 ... 1.6 Nm.

Where can I find technical support or manuals for this product?

Technical assistance can be reached via the hotline at +86-400-810-4288, or online through www.ad.siemens.com.cn/service.

What are some required wire size specifications for connections?