Manage your climate setting with this comprehensive guide for Sharp Room Air Conditioners. This essential manual provides step-by-step instructions covering everything from initial setup and optimal location planning to advanced operation modes like Sleep, On/Off Timers, and Energy Saver features. Designed for new owners of the AF series units, it ensures proper installation, efficient use, and regular maintenance, guaranteeing your unit runs safely and at peak performance.

📄 Preview 📖 Table of Contents Contents PAGE OF 20

Page 1 Text Content

AF-S100EX AF-S120EX AF-S125EX

ROOM AIR CONDITIONER INSTALLATION AND OPERATION AF-R100EX MANUAL

AF-R120EX

PAGECONTENTS

FOR YOUR PROTECTION.................... CONSUMER LIMITED WARRANTY INSTALLATION INSTRUCTIONS • CHECK WINDOW AREA • LOCATl ON • ITEMS PACKED WITH THl S UNIT • SUGGESTED TOOLS • INSTALLATION....................................... PRECAUTIONS • CAUTION FOR USE • GROUNDING INSTRUCTIONS • NOTES ON OPERATION • ENERGY EFFICIENCY TIPS HOW TO OPERATE • PARTS NAMES ...................................10 • COOLING OPERATION ......................11 • TO CHANGE FAN SPEED AND OPERATION MODE.......11 • TO CHANGE TEMPERATURE SETTING • TO CHANGE AIR FLOW DIRECTION • EXHAUST ............................................12 • ENERGY SAVER OPERATION...........13

This INSTALLATION AND OPERATION • SLEEP OPERATION ...........................13 MANUAL explains the proper use of your new

• ON TIMER OPERATION .....................14

Sharp Air Conditioner. Read these instructions

• OFF TIMER OPERATION....................15

carefully before installing or operating your air

• USING THE REMOTE CONTROL.......16

conditioner. The INSTALLATION AND OP-

CLEANING AND MAINTENANCE

ERATION MANUAL should be kept in a safe place for handy reference. BEFORE CALLING FOR SERVl CE

As an ENERGY STAR Partner, Sharp Electronics has determined that these products (AF-S100EX, AF- S120EX, AF-S125EX) meet the ENERGY STAR guidelines for energy efficient air conditioners. To meet these guidelines, air conditioners must be at least 10% more efficient than the minimum Federal standard.

Page Summary Contents For SHARP Room Air Conditioner R100EX AF-R120EX User Guide

Page 1 AF-S100EX AF-S120EX AF-S125EX ROOM AIR CONDITIONER INSTALLATION AND OPERATION AF-R100EX MANUAL AF-R120EX PAGECONTENTS FOR YOUR PROTECTION.................... CONSUMER LIMITED WARRANTY INSTALLATION INS...
Page 2 FOR YOUR PROTECTION To aid in answering questions if you call for service or for reporting loss or theft, please record below the model and serial number located on the right side of the unit. MODEL N...
Page 3 CONSUMER LIMITED WARRANTY CONSUMER LIMITED WARRANTY SHARP ELECTRONICS CORPORATION warrants to the first consumer purchaser that this Sharp brand product (the "Product"), when shipped in its ...
Page 4 INSTALLATION INSTRUCTIONS Before beginning installation, read these instructions carefully. Use the enclosed MOUNTING KIT for proper installation. CHECK WINDOW AREA The mounting kit is designed for wo...
Page 5 INSTALLATION INSTRUCTIONS ITEMS PACKED WITH THIS UNIT Accessories Q'ty Right closure assembly Left closure assembly Window sash foam seal Window sash foam seal (adhesive type) Top angle Screws(L=1&quo...
Page 6 INSTALLATION INSTRUCTIONS (1)3 Unscrew the 5 stopper screws of the cabinet. Keep the 3 screws from the front and side, as they will be used later. (2) Slide the chassis out from the cabinet by pulling...
Page 7 INSTALLATION INSTRUCTIONS Closure assembly (Left) Insert the closure assemblies on both sides into the rails of the jamb. Jamb (Left) Closure assembly (Left) 1/2 inch (13mm) Top angle Stool (1)9 Secur...
Page 8 PRECAUTIONS CAUTION FOR USE IMPORTANT: Points to keep in mind when using your air conditioner. Install the air conditioner by following the installation instructions given in the previous section of t...
Page 9 PRECAUTIONS NOTES ON OPERATION Allow 3 minutes for the compressor to restart cooling. If you turn the air conditioner off and immediately restart it, allow three minutes for the compressor to restart ...
Page 10 HOW TO OPERATE PARTS NAMES UNIT Front panel Cabinet Air inlet (Indoor side) Air outlet (Outdoor side) Vertical louvers Air inlet (Outdoor side) Horizontal louvers Filter handle Air outlet (Indoor side...
Page 11 HOW TO OPERATE COOLING OPERATION Touch POWER ON/OFF pad. The unit is preset at 74°F and HIGH COOL. This will show in the display when the power is first turned on. POWER indicator and COOL indica- tor...
Page 12 HOW TO OPERATE TO CHANGE TEMPERATURE SETTING During cooling operation Touch the TEMPERATURE setting pad to adjust the temperature set- ting. ---Lower temp. ---Raise temp. Temperature can be set within...
Page 13 HOW TO OPERATE ENERGY SAVER OPERATION During normal operation, the thermostat automatically controls cooling and the fan runs continu- ously. When the ENERGY SAVER OPERATION is selected, the thermosta...
Page 14 HOW TO OPERATE ON TIMER OPERATION This unit has a built-in timer that can be programmed to start the unit up to 12 hours in advance. You can set the timer to start in increments of 30 minutes (0.5 hou...
Page 15 HOW TO OPERATE OFF TIMER OPERATION This unit has a built-in timer that can be programmed to shut the unit off up to 12 hours in advance. You can set the timer to stop in increments of 30 minutes (0.5 ...
Page 16 HOW TO OPERATE USING THE REMOTE CONTROL INSTALLING BATTERIES Battery compartment cover Use two size-AA (R6) batteries. Open the battery compartment cover. Insert and slide the batteries into the compa...
Page 17 HOW TO OPERATE OPERATING WITH THE REMOTE CONTROL TRANSMITTER POWER ON/OFF button Push to start or stop the operation. TEMP. button TEMP. ---Raise temp. setting 1°F at a time. TEMP. ---Lower temp. sett...
Page 18 ENERGY EFFICIENCY TIPSCL ANING AND MAINTENANCE CLEANING THE FILTER If the filter is clogged with dust, the amount of air flow will be reduced, resulting in poor cooling performance. The filter should ...
Page 19 BEFORE CALLING FOR SERVl CE IF YOUR AIR CONDITIONER DOES NOT OPERATE PROPERLY, PLEASE CHECK THE FOLLOWING ITEMS BEFORE CALLING FOR SERVICE. AIR CONDITIONER DOES NOT OPERATE AT ALL Is the unit plugged ...
Page 20 SHARP ELECTRONICS CORPORATION Sharp Plaza, Mahwah, New Jersey 07430-2135 SHARP CORPORATION Osaka, Japan Printed in Thailand