This technical manual provides comprehensive installation instructions and service guidelines for industrial 855XC Horn / Xenon signaling devices. It details electrical specifications, operating within a robust temperature range of -20°C to +55°C, and emphasizes critical safety procedures like proper power disconnection and adherence to explosion-proof standards. Designed for maintenance professionals and electricians, the guide ensures safe setup and longevity in demanding industrial environments requiring high visibility warning signals.

📄 Preview PAGE OF 10

Page 1 Text Content

Installation Instructions Bulletin 855XC Horn /Xenon 110d B/ 5J

TEMPERATURE RANGE

IP66/67

FOURCHETTE DE TEMPERATURES

UL Type 4/4X/13

TEMPERATURBEREICH To maintain the ingress protection rating, both INTERVALLO TEMPERATURE FAIXA DE TEMPERATURA

cable entries must be fitted with suitably rated,

RANGO DE TEMPERATURA

certified cable entry and/or blanking devices during installation.

Input Input Max.

Catalog Number Voltage Current Input Volts 855XC-BND24A* 24V DC 559m A 30V 855XC-BNA10A* 120V 50/60Hz AC 184m A 132V

855XC-BNA20A* 230V 50/60Hz AC 84m A 253V Note: Input current will vary according to the input voltage level. The current values shown above are for the tone resulting in the maximum current draw (tone 1 - 340Hz Continuous).

DISCONNECT FROM POWER SOURCE TO PREVENT ELECTRICAL SHOCK BEFORE INSTALLING OR SERVICING. CHECK POWER SUPPLY VOLTAGE AND FREQUENCY DÉCONNECTER L’ALIMENTATION AVANT TOUTE OPÉRATION D’INSTALLATION OU DE MAINTENANCE, AFIN D’ÉVITER LES DÉCHARGES ÉLECTRIQUES. CONTROLER LA TENSION ET LA FRÉQUENCE D’ALIMENTATION SCHALTEN SIE DEN STROM WÄHREND DER INSTALLATION ODER BEI WARTUNGSARBEITEN AB UM EINEN ELEKTRISCHEN SCHLAG ZU VERMEIDEN. PRÜFEN SIE DIE SPANNUNG UND FREQUENZ DER STROMQUELLE SCOLLEGARE DALL’ALIMENTAZIONE PRIMA DELL’INSTALLAZIONE E DELLA MESSA IN SERVIZIO. CONTROLLARE LA TENSIONE DI ALIMENTAZIONE E LA FREQUENZA DESLIGAR A ALIMENTAÇÃO ANTES DE REALIZAR QUALQUER INTERVENÇÃO. VERIFICAR A TENSÃO E FREQUÊNCIA DA ALIMENTAÇÃO DURANTE EL PROCESO DE INSTALACIÓN O MANTENIMIENTO DESCONECTAR LA TENSIÓN DE ALIMENTACIÓN PARA EVITAR DESCARGAS ELÉCTRICAS. COMPROBAR TENSIÓN Y FRECUENCIA DE ALIMENTACIÓN

EXPLOSION HAZARD – SUBSTITUTION OF ANY COMPONENT MAY IMPAIR SUITABILITY FOR CLASS I, DIVISION 2 AND CLASS II DIVISION 2 DANGER D’EXPLOSION. LA SUBSTITUTION DE N'IMPORTE COMPOSANTS PEUT NUIRE À L'ADÉQUATION À LA CLASSE I, II DIVISION 2 EXPLOSIONSGEFAHR. AUSTAUSCH VON KOMPONENTEN KANN EIGNUNG FÜR KLASSE I, II, BEREICH 2 BEEINTRÄCHTIGEN PERICOLO DI ESPLOSIONE. LA SOSTITUZIONE DI COMPONENTI PUÒ INVALIDARE LA CONFORMITÀ DELL'APPARECCHIATURA ALLA CERTIFICAZIONE CLASSI I E II, DIVISIONE 2 PERIGO DE EXPLOSÃO. A SUBSTITUIÇÃO DE COMPONENTES PODE PREJUDICAR A CONFORMIDADE DA CLASSE I, II DIVISÃO 2 PELIGRO DE EXPLOSIÓN. LA SUSTITUCIÓN DE LOS COMPONENTES PUEDE RESULTAR PERJUDICIAL Y SER INAPROPIADO EN LA CLASE I, II DIVISIÓN 2 HAZARDOUS VOLTAGE MAY BE PRESENT WITH THE POWER OFF. WHEN SERVICING, DISCONNECT POWER AND THEN WAIT AT LEAST 5 MINUTES FOR CIRCUIT TO DISCHARGE BEFORE OPENING ENCLOSURE UNE TENSION DANGEREUSE PEUT ÊTRE PRÉSENTE HORS TENSION.. DÉCONNECTEZ L'ALIMENTATION ET ATTENDEZ QUE LE CIRCUIT SE DÉCHARGE (AU MOINS 5 MINUTES) AVANT L'ENTRETIEN BEI AUSGESCHALTETEM GERÄT KÖNNEN GEFÄHRLICHE SPANNUNGEN AUFTRETEN. VOR DER WARTUNG DIE STROMZUFUHR AUSSCHALTEN UND ANSCHLIEßEND MINDESTENS 5 MINUTES BIS ZR VOLLSTÄNDIGEN ENTLADUNG WARTEN È POSSIBILE CHE UNA CORRENTE ELETTRICA RESIDUA PERICOLOSA SIA SEMPRE DANNEGGIATA, ANCHE SE IL DISPOSITIVO È SPENTO. PRIMA DI EFFETTUARE LE OPERAZIONI DI MANUTENZIONE, SCOLLEGARE L'ALIMENTAZIONE E ATTENDERE ALMENO 5 MINUTI PERCHÉ LO SCARICO DEL CIRCUITO UMA VOLTAGEM PERIGOSA PODE ESTAR PRESENTE MESMO COM A ALIMENTAÇÃO DESATIVADA. ANTES DE FAZER A MANUTENÇÃO, DESLIGUE A ALIMENTAÇÃO E AGUARDE PELO MENOS S MINUTOS PARA QUE O CIRCUITO VOLTAJE PELIGROSO PUEDE ESTAR PRESENTE AUN CON EL EQUIPO APAGADO. PARA DAR MANTENIMIENTO, DESCONECTE LA ALIMENTACION Y ESPERE AL MENOS 5 MINUTOS PARA QUE EL CIRCUITO SE DESCARGUE ANTES DE ABRIR EL ENVOLVENTE. DO NOT OPEN WHEN AN EXPLOSIVE GAS OR DUST ATMOSPHERE IS PRESENT NE PAS OUVRIR EN PRÉSENCE D'UN GAZ EXPLOSIF OU D'UNE ATMOSPHÈRE POUSSIÉREUSE NICHT IN BEREICHEN MIT EXPLOSIVEM GAS ODER IN STAUBIGER ATMOSPHÄRE ÖFFNEN NON APRIRE IN PRESENZA DI GAS ESPLOSIVI O POLVERE NÃO ABRA QUANDO UM GÁS INFLAMÁVEL OU ATMOSFERA EMPOEIRADA ESTIVER PRESENTE NO ABRIR CUANDO EXISTA UNA ATMÓSFERA CON POLVO O GAS EXPLOSIVO

POTENTIAL ELECTROSTATIC CHARGING HAZARD – CLEAN ONLY WITH A DAMP CLOTH DANGER POTENTIEL CHARGE ÉLECTROSTATIQUE - NETTOYER UNIQUEMENT AVEC UN CHIFFON HUMIDE MÖGLICHE GEFAHR DURCH ELEKTROSTATISCHE LADUNG - NUR MIT FEUCHTEM TUCH REINIGEN RISCHIO DI CARICA ELETTROSTATICA POTENZIALE - PULIRE SOLO CON UN PANNO UMIDO RISCO POTENCIAL DE CARGA ELETROSTÁTICA - LIMPE SOMENTE COM UM PANO ÚMIDO PELIGRO POTENCIAL DE CARGA ELECTROSTÁTICA - LIMPIAR ÚNICAMENTE CON UN PAÑO HÚMEDO DIR 10004893344 (Version 01) Publication 855X-IN006A-EN-E- August 2019

Page Summary Contents For Rockwell Automation 855XC Xenon Horn Combination Instruction Sheet

Page 1 Installation Instructions Bulletin 855XC Horn /Xenon 110d B/ 5J TEMPERATURE RANGE IP66/67 FOURCHETTE DE TEMPERATURES UL Type 4/4X/13 TEMPERATURBEREICH To maintain the ingress protection rating, both I...
Page 2 Bulletin 855XC Horn /Xenon RATING AND MARKING INFORMATION NEC & CEC Class / Division Ratings for US / Canada 855XC-BN***A* combos comply with the following standards: ANSI/ISA 12.12.01-2015 CSA C2...
Page 3 Bulletin 855XC Horn /Xenon Installation must be carried out in compliance with the latest issue of the following standards: EN60079-14 / IEC60079-14: Explosive atmospheres - Electrical installations d...
Page 4 Bulletin 855XC Horn /Xenon Mounting screws not provided Vis de montage non-fournis Befestigungsschrauben sind im Lieferumfang nicht enthalten Viti di montaggio non incluse Parafusos para montagem não ...
Page 5 Bulletin 855XC Horn /Xenon Electrical Connection Wiring practices must meet applicable electrical codes. Raccordement Electrique Les procédures de câblage doivent répondre aux codes électriques en vig...
Page 6 Bulletin 855XC Horn /Xenon Volume S3 S2 DIP Switch (Tone selection) 0.56 Nm (5 lb-in) 0.45 Nm (4 lb-in) AC Terminals- HORN 8mm AC Terminals- XENON (0.31 in) 20-14AWG (0.5-2.5mm²) To energize the 3 sta...
Page 7 Bulletin 855XC Horn /Xenon DIP Switch Volume (Tone selection) (-8d B) 0.45 Nm (4 lb-in) 0.56 Nm (5 lb-in) 8mm DC Terminals- XENON DC Terminals- HORN (0.31 in) 20-14AWG (0.5-2.5mm²) To energize the 3 s...
Page 8 Bulletin 855XC Horn /Xenon Interchangeable Lens Cover WARNING – Hot surfaces. External surfaces and internal components ATTENTION may be hot after operation, take care when handling the equipment. The...
Page 9 Bulletin 855XC Horn /Xenon TONE SELECTION TABLE TABLEAU DE SELECTION DE SONS Example shown: 100000 = Tone 2 TONAUSWAHLTABELLE (Default setting) TABELLA DI SELEZIONE DELLA TONALITÀ TABELA DE SELEÇÃO DE...
Page 10 Bulletin 855XC Horn /Xenon Maintenance, Overhaul & Repair Maintenance, repair and overhaul of the equipment should only be carried out by suitably qualified personnel in accordance with the curren...

Manual Details

Brand Rockwell Automation
Pages 10
File Size 1.49 MB
Published June 06, 2026
33 views

Enter the captcha to get the download link:

captcha

Frequently Asked Questions

What safety steps must be taken before servicing the device?

Disconnect power and wait at least 5 minutes for the circuit to discharge before opening the enclosure.

How is the unit rated for hazardous areas?

The 855XC-BN***A* combos comply with Class I, Div 2 standards (ANSI/ISA 12.12.01-2015).

What is the required procedure to maintain the IP rating during installation?

Cable entries must be fitted with suitably rated, certified cable entry and/or blanking devices.

What type of cleaning solution should be used for this device?

Clean it only with a damp cloth due to potential electrostatic charging hazards.