# A B C D E F G H I J K L M N O P Q R S T U V W X Y Z

Panasonic EW3002 User's Manual

Summary

The Panasonic EW3002 is a reliable, non-invasive wrist blood pressure monitor designed for accurate at-home measurement of both systolic/diastolic blood pressure and pulse rate. This manual provides comprehensive instructions detailing correct usage, proper cuff positioning, safety precautions, and interpreting your readings. It is ideal for individuals managing chronic conditions or seeking to track vital signs regularly between doctor visits, helping you provide crucial data to your healthcare provider for better health management.

📄 Preview 📖 Table of Contents Contents PAGE OF 21

Page 1 Text Content

EW3002 2002.12.12 11:49 AM ページ a

Wrist Blood Pressure Monitor Monitor de presión arterial de colocación en la muñeca Operating Instructions Instrucciones de funcionamiento Model No. EW3002 Modelo No. EW3002

For questions or assistance with your blood pressure

monitor, call us at 1-800-338-0552.

SYS. mm Hg

DIA. mm Hg

Panasonic Consumer Electronics Company P/min.

A Unit of Matsushita Electric Corporation On/Off Start

of America One Panasonic Way 3D-1 Secaucus, NJ 07094

Before operating this device, please read these instructions completely and save this manual for future use.

No.1 EN,SP Antes de usar este dispositivo, lea completamente estas instrucciones y

© 2002 Matsushita Electric Works, Ltd. All Rights Reserved. Printed in China guarde este manual para utilizarlo como referencia en el futuro.

IS IC

Page Summary Contents For Panasonic EW3002 User's Manual

Page 1 EW3002 2002.12.12 11:49 AM ページ a Wrist Blood Pressure Monitor Monitor de presión arterial de colocación en la muñeca Operating Instructions Instrucciones de funcionamiento Model No. EW3002 Modelo No. ...
Page 2 EW3002 2002.12.12 11:49 AM ページ 1 Thank you for purchasing the Panasonic Wrist Blood Pressure Table of Contents Monitor EW3002. Designed for easy, one-touch operation, this monitor incorporates Precise...
Page 3 EW3002 2002.12.12 11:49 AM ページ 3 Basics of Blood Pressure Important Instructions Before Use Your heart acts like a pump, sending blood surging through your 1. Do not confuse self-monitoring with self-...
Page 4 EW3002 2002.12.12 11:49 AM ページ 5 6. Try to take your blood pressure measurements at the same time 10. Do not use the unit for any purpose other than measuring blood and under the same conditions every...
Page 5 EW3002 2002.12.12 11:49 AM ページ 7 Name and Function of Each Product Part Inserting/Replacing Batteries Fig. 1 1. Grasp the battery cover and remove it to the left as shown in Fig. 2-a. 2. Insert two 1....
Page 6 EW3002 2002.12.12 11:49 AM ページ 9 3. Open and relax your hand with the palm Positioning the Pressure Cuff Fig. 5 facing up. Closing your hand will cause inaccurate readings. CAUTIONS: Do not bend your ...
Page 7 EW3002 2002.12.12 11:49 AM ページ 11 Error Measuring Your Blood Pressure If “E” (meaning error) appears in the display (Fig.12) Fig. 12 during measurement, an error has occurred, e.g., you Relax during m...
Page 8 EW3002 2002.12.12 11:49 AM ページ 13 Easily Check Your Blood Pressure Readings Recalling Stored Data Against the World Health Organization (WHO) 1. Press the Recall button (Fig. 13). The A will appear in...
Page 9 EW3002 2002.12.12 11:49 AM ページ 15 About the Precise Logic™ Measurement System Care and Maintenance The blood flow (pulse wave) which influences blood pressure monitors varies 1. Use a dry, soft cloth ...
Page 10 EW3002 2002.12.12 11:49 AM ページ 17 Troubleshooting Symptom Possible cause The systolic pressure The hand with the cuff was held too low and Display Status before error Check points value or diastolic n...
Page 11 EW3002 2002.12.12 11:49 AM ページ 19 Specifications Method of measurement: Oscillometric System with Precise Logic™ Display: Digital LCD Measuring range: Blood pressure: 20 - 300 mm Hg Pulse rate: 30 - 1...
Page 12 EW3002 2002.12.12 11:49 AM ページ 21 Muchas gracias por adquirir el monitor de presión arterial Índice Panasonic EW3002 de colocación en la muñeca. Diseñado para ser usado de forma sencilla, con un solo ...
Page 13 EW3002 2002.12.12 11:49 AM ページ 23 Conocimientos básicos de la presión arterial Instrucciones importantes antes de usar la unidad Su corazón actúa como una bomba, enviando sangre por sus 1. No confunda...
Page 14 EW3002 2002.12.12 11:49 AM ページ 25 6. Trate de tomar las medidas de su presión arterial a la misma hora y 10. No use la unidad con ninguna otra finalidad que la de medir la bajo las mismas condiciones ...
Page 15 EW3002 2002.12.12 11:49 AM ページ 27 Nombre y función de cada parte Introducción/cambio de las pilas Figura 1 1. Sujete la tapa de las pilas y quítela tirando de ella hacia la izquierda como se muestra e...
Page 16 EW3002 2002.12.12 11:49 AM ページ 29 3. Abra y relaje su mano con la palma hacia Figura 5Colocación de la banda de presión arriba. Si cierra su mano las indicaciones no serán precisas. PRECAUCIONES: No d...
Page 17 EW3002 2002.12.12 11:49 AM ページ 31 Error Medida de su presión arterial Si aparece una “E” (significa error) en la pantalla (Figura Figura 12 12) durante la medida se habrá producido un error, por Reláj...
Page 18 EW3002 2002.12.12 11:49 AM ページ 33 Comprobación fácil de las indicaciones de Recuperación de datos almacenados su presión arterial en comparación con las 1. Presione el botón de recuperación (Figura 13...
Page 19 EW3002 2002.12.12 11:49 AM ページ 35 Acerca del sistema de medida Precise Logic™ Cuidados y mantenimiento El flujo de la sangre (onda de pulso) que influye en los monitores de presión 1. Use un paño seco...
Page 20 EW3002 2002.12.12 11:49 AM ページ 37 Localización y solución de problemas Síntomas Causa posible El valor de la presión La mano con la banda se mantuvo Visualización Estado antes del error Puntos de comp...
Page 21 EW3002 2002.12.12 11:49 AM ページ 39 Especificaciones Método de medida: Sistema oscilométrico con Precise Logic™ Pantalla: Pantalla LCD Margen de medida: Presión arterial: 20 - 300 mm Hg Frecuencia del p...

Manual Details

Brand Panasonic
Pages 21
File Size 331.22 KB
Published June 21, 2026
7 views

Enter the captcha to get the download link:

captcha

Frequently Asked Questions

What is the blood pressure range this monitor measures?

The monitoring range for blood arterial pressure is 20 - 300 mmHg.

How accurate is the measurement according to the specifications?

The accuracy specifications are ±4 mmHg for blood arterial pressure and ±5% for pulse rate.

What type of power source does the EW3002 require?

It requires two alkaline 1.5-volt batteries (AAA/LR03).

How must I position myself when taking a reading?

The manual advises measuring while sitting down, mentioning that measurements taken in lying down or standing may differ.