The ZFV-C is a sophisticated sensor and controller requiring precise external interaction. This comprehensive technical manual serves as an essential command reference for mastering non-procedural communication protocols. It guides advanced users, specifically those knowledgeable in electrical engineering, through setting up communication specifications (USB/RS-232C), acquiring settings data, executing complex measurements, and managing system parameters like SAVESAVE or LOADBANK commands. Use this guide to deeply integrate the ZFV-C into automated monitoring systems.

📄 Preview PAGE OF 22

Page 1 Text Content

Smart Sensor ZFV-C

Non-procedural Communication Command Reference

Cat. No. Z244-E1-01

Page Summary Contents For OMRON ZFV-C ZFV-C Smart Sensors Non-procedural Communication Command Reference

Page 1 Smart Sensor ZFV-C Non-procedural Communication Command Reference Cat. No. Z244-E1-01
Page 2 1intro.fm 1 ページ 2006年6月6日 火曜日 午後6時29分 Introduction Thank you for purchasing the ZFV-C. This manual provides reference information on non-procedural communication commands for the ZFV-C. When using the...
Page 3 1feature.fm 1 ページ 2006年6月6日 火曜日 午後6時30分 Contents Contents Setting the Communication Specifications Format List of Non-procedural Commands Parameter List (ZFV-C) Acquiring/Sending Data Example of Usage...
Page 4 1feature.fm 2 ページ 2006年6月6日 火曜日 午後6時30分 Setting the Communication Specifications Setting the Communication Specifications Change the settings of the controller communication specifications for non-pro...
Page 5 1feature.fm 3 ページ 2006年6月6日 火曜日 午後6時30分 Format Format The format of non-procedural commands is as follows. Example: Command to execute measurement MEASURE command * Each character is output as an ASCI...
Page 6 1feature.fm 4 ページ 2006年6月6日 火曜日 午後6時30分 List of Non-procedural Commands List of Non-procedural Commands Command name Format Returned value Description BANKSET BANKSET OK <delimiter> Switches the...
Page 7 1feature.fm 5 ページ 2006年6月6日 火曜日 午後6時30分 Parameter List (ZFV-C) Parameter List (ZFV-C) The following parameters can be acquired or set by the DATASET or DATAGET command. "Common" parameters a...
Page 8 1feature.fm 6 ページ 2006年6月6日 火曜日 午後6時30分 Parameter List (ZFV-C) Area 1 (AREA1)/Area 2 (AREA2)/Area 3 (AREA3) Setting range/output Unit No. Parameter No. Parameter Remarks range Judgment -2: measurement...
Page 9 1feature.fm 7 ページ 2006年6月6日 火曜日 午後6時30分 Parameter List (ZFV-C) Unit No. Parameter No. Parameter Setting range/output range Remarks Average density 0 to 255 DATASET/DATAGET upper limit value compatible...
Page 10 1feature.fm 8 ページ 2006年6月6日 火曜日 午後6時30分 Parameter List (ZFV-C) Position (POSITION) Unit No. Parameter No. Parameter Setting range/output range Remarks Judgment -2: measurement off DATAGET compatible -...
Page 11 1feature.fm 9 ページ 2006年6月6日 火曜日 午後6時30分 Parameter List (ZFV-C) Character (CHARA1)/Character (CHARA2) Parameter Setting range/output Unit No. Parameter Remarks No. range Judgment -2: measurement off DA...
Page 12 1feature.fm 10 ページ 2006年6月6日 火曜日 午後6時30分 Acquiring/Sending Data Acquiring/Sending Data Flow of XMODEM communication When you capture image data by entering this command, image data is acquired and sen...
Page 13 1feature.fm 11 ページ 2006年6月6日 火曜日 午後6時30分 Acquiring/Sending Data Data transmission to ZFV-C from personal computer (issue of SYSLOAD command) Host device (personal ZFV-C computer) BANKLOAD/SYSLOAD comm...
Page 14 1feature.fm 12 ページ 2006年6月6日 火曜日 午後6時30分 Example of Usage Example of Usage The following describes an example procedure to communicate by non-procedural commands using Windows standard tool Hyper Term...
Page 15 1feature.fm 13 ページ 2006年6月6日 火曜日 午後6時30分 Example of Usage (3) Set the communication conditions. (4) Hyper Terminal is started up. 2. To facilitate command transactions, set echo and other communicatio...
Page 16 1feature.fm 14 ページ 2006年6月6日 火曜日 午後6時30分 Example of Usage (2) Select the Settings tab, and then ASCII Setup. (3) Mark the following checkboxes, and click OK to complete the setting. 3. Set the communi...
Page 17 1feature.fm 15 ページ 2006年6月6日 火曜日 午後6時30分 Example of Usage (1) Enter a command, and then press the return key. (2) The returned value corresponding to the command is returned from the controller. ZFV-C...
Page 18 1feature.fm 16 ページ 2006年6月6日 火曜日 午後6時30分 Example of Usage ZFV-C Non-procedural Communication Command Reference
Page 19 1feature.fm 17 ページ 2006年6月6日 火曜日 午後6時30分 Example of Usage ZFV-C Non-procedural Communication Command Reference
Page 20 1feature.fm 18 ページ 2006年6月6日 火曜日 午後6時30分 Example of Usage ZFV-C Non-procedural Communication Command Reference
Page 21 1feature.fm 19 ページ 2006年6月6日 火曜日 午後6時30分 Revision History Revision History Revision code Date Revised contents January 2006 Original production May 2006 Function added as per software version upgrade ...
Page 22 OMRON Corporation Industrial Automation Company Sensing Devices Division H.Q. Application Sensors Division Shiokoji Horikawa, Shimogyo-ku, Kyoto, 600-8530 Japan Tel: (81)75-344-7068/Fax: (81)75-344-71...

Manual Details

Brand Omron
Pages 22
File Size 543.67 KB
Published June 04, 2026
55 views

Enter the captcha to get the download link:

captcha

Frequently Asked Questions

How do I connect ZFV-C to an external communication device?

Use either a USB cable or RS-232C cable connection. If using USB, you must download and install the required driver by contacting your OMRON representative.

In what operational mode can non-procedural commands be accepted?

Communication commands are only accepted when the controller is switched to [RUN] mode, which executes the saving of specifications.

What is the indication if a non-procedural command fails or results in an error?

If the command was not executed successfully or the setting resulted in NG, the return value will be 'ER' (Error).