This manual provides comprehensive technical guidance for the POSISwitch AX 5000 module, a specialized electrical resource designed to power servo machines within high-voltage industrial automation systems. It details crucial aspects of mounting, commissioning, and connection procedures for POSIDRIVE/MDS drives. This documentation is essential for skilled technicians and engineers responsible for implementing or maintaining advanced control and motion management infrastructure, ensuring compliance with stringent safety standards and optimal system performance.

📄 Preview 📖 Table of Contents Contents PAGE OF 20

Page 1 Text Content

AXIS SWITCH POSISwitch® AX 5000 for POSIDRIVE® MDS 5000

Mounting and Commissioning Guidelines

Be sure to read and adhere to this mounting and commissioning instructions before mounting and commissioning!

MANAGEMENTSYSTEM

certified by DQS according to DIN EN ISO 9001, DIN EN ISO 14001 Reg-No. 000780 UM/QM

COMMISSIONING

CONNECTION

MOUNTING

SV 5.1 02/2005

Page Summary Contents For MDS AXIS SWITCH POSI Switch AX 5000 User's Manual and Specifications

Page 1 AXIS SWITCH POSISwitch® AX 5000 for POSIDRIVE® MDS 5000 Mounting and Commissioning Guidelines Be sure to read and adhere to this mounting and commissioning instructions before mounting and commissioni...
Page 2 POSISwitch® AX 5000 STÖBER ANTRIEBSTECHNIK Table of Contents TABLE OF CONTENTS 1. Notes on Safety 1 2. Technical Data 2 2.1 Electrical 2 2.2 Mechanical 3 3. Mechanical Installation 4 3.1 Installation ...
Page 3 POSISwitch® AX 5000 STÖBER ANTRIEBSTECHNIK 1. Notes on Safety 1 NOTES ON SAFETY Before mounting and commissioning, be sure to read these mounting and commissioning instructions to prevent the occurren...
Page 4 POSISwitch® AX 5000 STÖBER ANTRIEBSTECHNIK 2. Technical Data 2 TECHNICAL DATA Model key POSISwitch® AX 5000/4 Designation Number of axes 5. Generation 2.1 Electrical Device Type POSISwitch® AX 5000/4 ...
Page 5 POSISwitch® AX 5000 STÖBER ANTRIEBSTECHNIK 2. Technical Data 2.2 Mechanical Specifications in mm
Page 6 POSISwitch® AX 5000 STÖBER ANTRIEBSTECHNIK 3. Mechanical Installation 3 MECHANICAL INSTALLATION This chapter gives you complete information on the subject of mechanical installation. Only specialized ...
Page 7 POSISwitch® AX 5000 STÖBER ANTRIEBSTECHNIK 4. Electrical Installation 4 ELECTRICAL INSTALLATION This chapter gives you complete information on the subject of electrical installation. Only specialized ...
Page 8 POSISwitch® AX 5000 STÖBER ANTRIEBSTECHNIK 5. Connection Allocation 5 CONNECTION ALLOCATION This section explains the position, designation and allocation of the terminals. 5.1 Terminal Overview X500 ...
Page 9 POSISwitch® AX 5000 STÖBER ANTRIEBSTECHNIK 5. Connection Allocation X501 – voltage supply and relays PIN1 Signal / Function Description Circuiting Voltage supply 1 +24VDC Powers POSISwitch® AX 5000 an...
Page 10 POSISwitch® AX 5000 STÖBER ANTRIEBSTECHNIK 5. Connection Allocation Enc. 1; Enc. 2; Enc 3; Enc. 4 – connection for encoders 1 - 4 PIN1 Signal / Function Description Circuiting 1 NC Not connected 2 GND...
Page 11 POSISwitch® AX 5000 STÖBER ANTRIEBSTECHNIK 6. Configuration 6 CONFIGURATION This chapter describes the configuration of POSISwitch® AX 5000. The user decides whether POSISwitch® will be used in the co...
Page 12 POSISwitch® AX 5000 STÖBER ANTRIEBSTECHNIK 7. Examples 7 EXAMPLES ID IV 7.1 Principal Circuit Diagram (without Shielding) L1L1 L2L2 L3L3 PEPE M1 M2 M3 M4 X10 X2 X302 K1 K2 K3 K4 Brake Brake Brake Brak...
Page 13 POSISwitch® AX 5000 STÖBER ANTRIEBSTECHNIK 8. Accessories 8 ACCESSORIES ID No. Designation Remarks 45405 POSISwitch® connection cable (0.5 m) Chap. 3 Connection cable POSISwitch® AX 5000 to POSIDRIVE®...
Page 14 STÖBER ANTRIEBSTECHNIK - Deutschland STÖBER ANTRIEBSTECHNIK Hauptverwaltung: STÖBER ANTRIEBSTECHNIK Gmb H & Co. KG Fon 07231 582-0 Postfach 910103 Fax 07231 582-1000 75091 Pforzheim e Mail sales@s...
Page 15 STÖBER ANTRIEBSTECHNIK - Deutschland STÖBER ANTRIEBSTECHNIK Zugehörige Technische Büros: Pforzheim Süd STÖBER ANTRIEBSTECHNIK Gmb H & Co. KG Fon 07231 582-1229 Günter Großmann Fax 07231 582-1349 P...
Page 16 STÖBER ANTRIEBSTECHNIK - International STÖBER ANTRIEBSTECHNIK Austria STÖBER ANTRIEBSTECHNIK Gmb H Phone +43 7613 76000 Fabriksplatz 1 Fax +43 7613 76009 4662 Steyrermühl e Mail [email protected] Fran...
Page 17 STÖBER ANTRIEBSTECHNIK - International STÖBER ANTRIEBSTECHNIK Finland EIE MASKIN OY Phone +358 19 2461642 PL 80 Fax +358 19 2461643 10600 Tammisaari e Mail [email protected] Hungary BDI Hungary Ltd. Phone +3...
Page 20 Additional information under: http://www.stoeber.de TÖ TR IE TE IK b H o. ub lic at io no . 4 9. .0 · 0 2. - S ub je ct to te ch ni ca l c ha ng ith ou t p rio r n ot ic STÖBER . . . The Drive for you...

Manual Details

Brand Axis
Pages 20
File Size 1.33 MB
Published May 15, 2026
223 views

Enter the captcha to get the download link:

captcha

Frequently Asked Questions

Who should perform the mounting and commissioning of this module?

The device can only be transported, installed, commissioned, and controlled by specialized personnel who are qualified for this task.

What systems is the POSISwitch AX 5000 certified to operate with?

It is exclusively intended for powering servo machines and is only certified for operation on POSIDRIVE of the MDS family.

What specific safety precautions must be followed during installation?

Installation work may only be performed when the power is disconnected, requiring an inhibit of the inverter's enable and a disconnection from the main power network.