# A B C D E F G H I J K L M N O P Q R S T U V W X Y Z

Dell EMC OpenManage Message Reference Guide Version 9.4 User's ManualNote: The first title "Owner's Manual" is already in English, so no translation needed for it.

Summary

The Dell EMC OpenManage Message Reference Guide version 9.4 provides a comprehensive catalog of event and alert messages generated by Dell server management software. It covers alert message change history, event message format and interpretation, and message logging to Unicode text files. Server administrators can use this reference to decode hardware alerts, identify failing components, and determine corrective actions across Windows, Linux, and ESXi managed systems.

📄 Preview 📖 Table of Contents Contents PAGE OF 199

Page 1 Text Content

Dell EMC Open Manage Message Reference Guide Version 9.4

Page Summary Contents For Dell EMC OpenManage Message Reference Guide Version 9.4 User's ManualNote: The first title "Owner's Manual" is already in English, so no translation needed for it.

Page 1 Dell EMC Open Manage Message Reference Guide Version 9.4
Page 2 Notes, cautions, and warnings NOTE: A NOTE indicates important information that helps you make better use of your product. CAUTION: A CAUTION indicates either potential damage to hardware or loss of d...
Page 3 Contents 1 Introduction................................................................................................................................15 New in this release..............................
Page 4 Cooling Device Messages...................................................................................................................................................29 Event ID — 1100...............
Page 5 Event ID — 1426........................................................................................................................................................... Event ID — 1427.................
Page 6 Event ID — 2048.......................................................................................................................................................... Event ID — 2049..................
Page 7 Event ID — 2109........................................................................................................................................................... Event ID — 2110.................
Page 8 Event ID — 2163........................................................................................................................................................... Event ID — 2164.................
Page 9 Event ID — 2215........................................................................................................................................................... Event ID — 2216.................
Page 10 Event ID — 2266..........................................................................................................................................................112 Event ID — 2267...............
Page 11 Event ID — 2319.......................................................................................................................................................... Event Id — 2320..................
Page 12 Event ID — 2372......................................................................................................................................................... Event ID — 2373...................
Page 13 Event ID — 2435......................................................................................................................................................... Event ID — 2436...................
Page 14 Event ID — 2909.......................................................................................................................................................... Event ID — 2910..................
Page 15 Introduction Open Manage Server Administrator generates event messages stored primarily in the operating system or Server Administrator event logs and sometimes in Simple Network Management Protocol (...
Page 16 Storage Management 4.4 Server Administrator 7.3.0 New Alerts Deleted Alerts None Modified Alerts None Storage Management 4.2 Product Versions to which changes apply Storage Management 4.2.0 Server Adm...
Page 17 Storage Management 4.4 Storage Management 3.3 Product Versions to which changes apply Storage Management 3.3.0 Server Administrator 6.3.0 New Alerts Deleted Alerts None Modified Alerts Alert severity ...
Page 18 Chassis Intrusion Sensor — Monitors intrusion into the chassis and attached system(s). Redundancy Unit Sensor — Monitors redundant units (critical units such as fans, AC power cords, or power supplies...
Page 19 openmanage directory. The Server Administrator event log file is located in the /etc/cim/dell/srvadmin/log/ openmanage directory. Logging Messages to a Unicode Text File Logging messages to a Unicode ...
Page 20 Time — The local time the event occurred. Type — A classification of the event severity: Information, Warning, or Error. User — The name of the user on whose behalf the event occurred. Computer — The ...
Page 21 Description Line Device location: <Location in chassis> Item Explanation Specifies the location of the device in the specified chassis, for example: Device location: Memory Card Description Line...
Page 22 Description Line Power Supply type: <type of power supply> Item Explanation Specifies the type of power supply, for example: Power Supply type: VRM Description Line Previous redundancy state was...
Page 23 Server Management Messages The following tables lists in numerical order each event ID and its corresponding description, along with its severity and cause. NOTE: For corrective actions, see the appro...
Page 24 Cause Server Administrator is beginning to initialize. Event ID — 1001 Description Server Administrator startup complete Severity Information Cause Server Administrator completed initialization. Event...
Page 25 Event ID — 1007 Description User initiated host system control action Action requested was: <Action> Severity Information Cause User requested a host system control action to reboot, power off, ...
Page 26 Date and time of action: <Date and time> Severity Warning Cause This event is generated when the systems management agent detects a critical system software generated event in the system event l...
Page 27 Temperature Sensor Messages The temperature sensors listed help protect critical components by alerting the systems management console when temperatures become too high inside a chassis. The temperatu...
Page 28 Event ID — 1053 Description Temperature sensor detected a warning value Sensor location: <Location in chassis> Chassis location: <Name of chassis> Previous state was: <State> If sens...
Page 29 Cooling Device Messages The cooling device sensors listed monitor how well a fan is functioning. Cooling device messages provide status and warning information for fans in a particular chassis. Event ...
Page 30 Event ID — 1104 Description Fan sensor detected a failure value Sensor location: <Location in chassis> Chassis location: <Name of chassis> Previous state was: <State> Fan sensor valu...
Page 31 Voltage sensor value (in Volts): <Reading> If sensor type is discrete: Discrete voltage state: <State> Severity Warning Cause A voltage sensor in the specified system could not obtain a re...
Page 32 Cause A voltage sensor in the specified system exceeded its failure threshold. The sensor location, chassis location, previous state, and voltage sensor value information is provided. Event ID — 1155 ...
Page 33 Discrete voltage state: <State> Severity Warning Cause A current sensor in the specified system could not obtain a reading. The sensor location, chassis location, previous state, and a nominal c...
Page 34 Discrete voltage state: <State> Severity Error Cause A current sensor in the specified system exceeded its failure threshold. The sensor location, chassis location, previous state, and current s...
Page 35 Event ID — 1254 Description Chassis intrusion detected Sensor location: <Location in chassis> Chassis location: <Name of chassis> Previous state was: <State> Chassis intrusion state:...
Page 36 Cause A Drive Bay intrusion has been detected for extended period of time the system cover was opened while the system was operating. The sensor location, chassis location, previous state, and chassis...
Page 37 Previous redundancy state was: <State> Severity Information Cause A redundancy sensor in the specified system detected that a redundant unit is offline. The redundancy unit location, chassis loc...
Page 38 Power Supply type: <type of power supply> <Additional power supply status information> If in configuration error state: Configuration error type:<type of configuration error> Severit...
Page 39 Configuration error type:<type of configuration error> Severity Error Cause A power supply has been disconnected or has failed. The sensor location, chassis location, previous state, power suppl...
Page 40 Possible memory module event cause: <list of causes> Severity Warning Cause A memory device correction rate exceeded an acceptable value. The memory device status and possible memory module even...

Manual Details

Brand Dell
Pages 199
File Size 1.30 MB
Published June 28, 2026
4 views

Enter the captcha to get the download link:

captcha

Frequently Asked Questions

How can I access viewing the recorded event messages?

Event summaries can be viewed on Red Hat Enterprise Linux, SUSE Linux Enterprise Server, or VMware ESXi.

Do I need to manually record the message logs?

No, you have the option of logging messages to a Unicode Text File.

Where can I find information about product updates?

There is a dedicated section for 'New in this release' detailing changes and additions.

How do I determine if a message description is accurate?

You must consult the detailed 'Understanding the Event Description' to confirm its context.