Page 1
Dell Chassis Management Controller Version 2.10 for Power Edge FX2 and FX2s RACADM CLI Guide
Page 2
Notes, cautions, and warnings NOTE: A NOTE indicates important information that helps you make better use of your product. CAUTION: A CAUTION indicates either potential damage to hardware or loss of d...
Page 3
Contents 1 Introduction................................................................................................................................................... What’s new in this release......
Page 4
getniccfg........................................................................................................................................................................... getpbinfo.............
Page 5
testfeature........................................................................................................................................................................ testtrap...............
Page 6
cfg Ssn Mgt Webserver Timeout (Read/Write).......................................................................................................109 cfg Serial............................................
Page 7
cfg Rac Tune Fips Mode Enable...................................................................................................................................122 cfg Rac Tune TLSProtocol Version Ena...
Page 8
cfg ADDc SRVLookup Domain Name (Read/Write)................................................................................................ cfg ADDc SRVLookup Domain Name (Read/Write)....................
Page 9
cfg Chassis Power Cap Lower Bound (Read Only)...................................................................................................145 cfg Chassis Sled Power Button Enable...................
Page 10
cfg Current IPv6Auto Config Was Used..................................................................................................................... cfg Current Link Local Address...................
Page 11
Introduction This document provides information about the RACADM subcommands, supported RACADM interfaces, and property database groups and object definitions of CMC for Power Edge FX2/FX2s. NOTE: The...
Page 12
Remote RACADM racadm -r <rac Ip Addr> -u <username> -p <password> getconfig -g <groupname> [-o <objectname>] [-i <indexnumber>] racadm -r <rac Ip Addr> -u <...
Page 13
abcdefghijklmnopqrstuvwxwz ABCDEFGHIJKLMNOPQRSTUVWXYZ Supported RACADM Subcommands Table 3. Details of Subcommands Subcommand CMC Telnet/SSH/Serial Remote RACADM “?” and “?<subcommand>” Yes Yes ...
Page 14
Subcommand CMC getpminfo Yes Yes getraclog Yes Yes getractime Yes Yes getsel Yes Yes getsleduplinkstatus Yes Yes getsensorinfo Yes Yes getslotname Yes Yes getssninfo Yes Yes getsvctag Yes Yes getsysin...
Page 15
Subcommand CMC sslresetcfg Yes Yes testemail Yes Yes testfeature Yes Yes testtrap Yes Yes traceroute Yes Yes traceroute6 Yes Yes Other Documents You May Need To access the documents from the Dell Supp...
Page 16
RACADM Subcommand Details This section provides detailed descriptions about the RACADM subcommands, including the syntax and valid entries. Topics: Guidelines to Quote Strings Containing Special Chara...
Page 17
getsensorinfo getssninfo getstoragemoduleinfo getsvctag getsysinfo gettracelog getversion ifconfig jobqueue krbkeytabupload license netstat ping ping6 racdump racreset racresetcfg remoteimage serverac...
Page 18
Strings containing the following special characters must be quoted using double quotation marks: $ (dollar sign) " (double quotation mark) ` (backward quotation mark) \ (backward slash) ~ (tilde)...
Page 19
racadm ? <subcommand> Input NA Output NA Example for RACADM ? The following output example shows only part of the actual output for the racadm ? command. Descriptions shown in this example may v...
Page 20
Output The help command displays a complete list of subcommands. The racadm help <subcommand> command displays information for the specified subcommand only. The racadm help -g <groupname>...
Page 21
Example Display the number of records present in the Chassis Log: racadm chassislog view -i Display the records having severities set to warning or critical, starting from sequence number 4: racadm ch...
Page 22
chassislog clear Table 8. Details of chassislog clear Description Deletes the data in the chassis log. To clear the chassis log, you must have the Clear Logs Administrator privilege. Synopsis racadm c...
Page 23
closessn Table 10. Details of closessn Description Closes a communication session on the device. Use the getssninfo command to view a list of sessions that can be closed using this command. To use thi...
Page 24
Clear sel log on server 2a: racadm clrsel -m server-2a config Table 12. Details of config Description Allows you to set CMC configuration parameters individually or to batch them as part of a configur...
Page 25
NOTE: The myrac.cfg file does not contain passwords. To include passwords in the file, you must enter them manually. If you want to remove password information from the myrac.cfg file during configura...
Page 26
Legal values: device=None, PXE, HDD, CD-DVD, v FDD, v CD-DVD, SD, FDD, RFS -o < no|yes > — Indicates if the server should boot from the device once; must be used with -o. Use with -m <module&...
Page 27
eventfilters Table 15. Details of eventfilters Description Gets, sets, and displays the list of event filter settings. To use this subcommand with the get option, you must have the CMC Login User priv...
Page 28
Display eventfilter configurations for a specific subcategory. For example, licensing under the audit category: racadm eventfilters get -c cmc.alert.audit.lic Display eventfilter configurations for a ...
Page 29
feature Table 17. Details of feature Description Displays all active chassis features. The information displayed includes feature name, date activated, and the serial number of the SD card used to act...
Page 30
CMC: The feature card inserted is valid, serial number = CN0H871T137401112222A00 The feature card contains the following feature(s): Flex Address: bound Flex Address Plus: bound Extended Storage: boun...
Page 31
Input NOTE: Firmware update from local RACADM (using the -p, -u, or -d options) is not supported on Linux operating system. -p — The -p option is used to update the firmware file from the client. The ...
Page 32
Cancel a firmware update in progress: racadm fwupdate -c Signed CMC Firmware Image: racadm fwupdate –g –u –a <TFTP IP> -d <Firmware Path> -m Firmware update has been initiated. This update...
Page 33
-p: password for the remote share where the file must be exported. -l: network share location where the file must be exported. -t: specify the file type that has to be exported. Valid value is “XML”. ...
Page 34
getassettag Table 23. Details of getassettag Description Displays the asset tag for the chassis. To use this subcommand, you must have the CMC Login User privilege. Synopsis racadm getassettag [-m <...
Page 35
-h — The -h, or help option, displays a list of all available configuration groups in alphabetical order. This option is useful when you do not have exact group names. -i — The -i <index>, or in...
Page 36
Group Key Attribute cfg Standard Schema cfg SSADRole Group Name cfg Traps cfg Traps Alert Dest IPAddr cfg User Admin cfg User Admin User Name Displays a list of the available configuration groups on C...
Page 37
Table 30. getdcinfo <Server#> <Presence> <DC1 Model Name> <DC2 Model Name> server-1 Present None None server-2 Not Present None None server-3 Not Present None None server-4 Pre...
Page 38
NOTE: If Flex Address is not activated on the chassis, the command displays server- assigned MAC/WWN addresses. If the slot is empty, the command leaves the server- assigned MAC/WWN addresses blank. I...
Page 39
10 Gb E KR/ 00:90:FA: F0:1F:AF:88:22:75(active) FCo E- 10:00:00:90:FA:51:31:E5 20:01:F0:1F:AF:88:22:75(active) WWN 10 Gb E 10:00:00:90:FA:51:31:E5 20:01:F0:1F:AF:88:22:75(active) KR 10 Gb E 00:90:FA:5...
Page 40
NOTE: 10 Gb E KR/3 — The value 3 indicates the protocol type. getioinfo Table 35. Details of getioinfo Description Displays general information about the stack and I/O modules on the chassis. To use t...