Page 1
Chassis Management Controller Version 1.35 for Dell Power Edge VRTX User's Guide
Page 2
Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make better use of your computer. CAUTION: A CAUTION indicates either potential damage to hardware or loss of ...
Page 3
Contents 1 Overview............................................................................................................... What Is New In This Release.............................................
Page 4
Configuring Initial CMC Network................................................................................................. Interfaces and Protocols to Access CMC....................................
Page 5
Enabling or Disabling Warning Message to Change Default Login Password Using RACADM........................................................................................................................
Page 6
Viewing Information and Health Status of All Servers....................................................................... Viewing Health Status and Information for Individual Server....................
Page 7
Chassis Group Inventory and Firmware Version..........................................................................84 Viewing Chassis Group Inventory ..................................................
Page 8
8 Configuring CMC To Send Alerts.................................................................. Enabling Or Disabling Alerts............................................................................
Page 9
Configuring CMC SSO Or Smart Card Login For Active Directory Users Using RACADM.......138 11 Configuring CMC to Use Command Line Consoles................................. CMC Command Line Console Feat...
Page 10
Managing Power Control Operation for I/O Modules.................................................................... Enabling or Disabling LED Blinking for I/O Modules....................................
Page 11
Executing Power Control Operations on IOM Using CMC Web Interface...............................180 Executing Power Control Operations on the IOM Using RACADM.............................................
Page 12
Supported Interfaces...................................................................................................................195 Downloading SNMP Management Information Base (MIB) File.........
Page 13
Overview The Dell Chassis Management Controller (CMC) for Dell Power Edge VRTX is a Systems Management hardware and software solution for managing the Power Edge VRTX chassis. The CMC has its own micr...
Page 14
I/O fabric consistency checks between the I/O module and servers. CMC also disables components, if necessary, to protect the system hardware. User access security. Storage components, including the fa...
Page 15
Flex Address feature — Replaces the factory-assigned World Wide Name/Media Access Control (WWN/ MAC) IDs with chassis-assigned WWN/MAC IDs for a particular slot, an optional upgrade. Graphical display...
Page 16
Item Indicator, Button, or Connector Status/identification indicator (CMC 1) Power indicator (CMC 1) CMC connector ports (2) Power indicator (CMC 2) Status/identification indicator (CMC 2) A Back Pane...
Page 17
Item Indicator, Button, or Connector CMC GB Ethernet port (CMC-1) Serial Connector Blower modules (4) I/O module ports PSU 4 PSU 3 PSU 1 PSU 2 A Front Panel view of the chassis is given here with a ta...
Page 18
Ite Indicator, Button, or Description Connector USB connectors (2) Allows a keyboard and mouse to be connected to the system. LCD panel Provides system information and status, and error messages to in...
Page 19
Connection Features Support for binary interchange for applications specifically designed to communicate with a binary protocol to a particular type of I/O Module. Serial port can be connected interna...
Page 20
Acquiring Licenses Use any of the following methods to acquire the licenses: E-mail — License is attached to an e-mail that is sent after requesting it from the technical support center. Self-service ...
Page 21
License/ Import Export Delete Replace Learn More Component state or condition Non-administrator Yes No No No Yes login Active license Yes Yes Yes Yes Yes Expired license No Yes Yes Yes Yes License ins...
Page 22
WS-MAN Yes Yes SNMP Yes Yes Telnet Yes Yes SSH Yes Yes Web-based Interface Yes Yes Email Alerts Yes Yes LCD Deployment Yes Yes Extended i DRAC Yes Yes Management Remote Syslog No Yes Directory Service...
Page 23
Flex Address Enablement No* Yes *For non-default Flex Address settings, only Restore Default is allowed with Express license. Restore Default will reset the Flex Address settings to the factory defaul...
Page 24
The Chassis Management Controller Version 1.0 for Dell Power Edge VRTX RACADM Command Line Reference Guide provides information about using the VRTX–related RACADM features. The Dell Chassis Managemen...
Page 25
Using the following links: For all Systems Management documents — dell.com/softwaresecuritymanuals For Remote Enterprise Systems Management documents — dell.com/esmmanuals For Enterprise Systems Manag...
Page 26
Installing and Setting Up CMC This section provides information about how to install your CMC hardware, establish access to CMC, configure your management environment to use CMC, and guides you throug...
Page 27
8. Provide each i DRAC with an IP address in the CMC web interface, and enable the LAN and IPMI interface. NOTE: i DRAC LAN interface on some servers are disabled by default. This information can be f...
Page 28
5. For help about the RACADM command, type racadm help after you run the previous commands. For more information about RACADM, see the Chassis Management Controller for Dell Power Edge VRTX RACADM Com...
Page 29
5. In the Exceptions section, add the addresses for CMCs and i DRACs on the management network to the semicolon-separated list. You can use DNS names and wildcards in your entries. Mozilla Fire Fox To...
Page 30
Enabling Animations In Internet Explorer When transferring files to and from the web interface, a file transfer icon spins to show transfer activity. While using Internet explorer, you have to configu...
Page 31
Command line interfaces (CLIs) such as a serial console, Telnet, SSH, or the Dell CMC console. Remote RACADM CMC web interface LCD Panel interface CMC supports both IPv4 and IPv6 addressing modes. The...
Page 32
NOTE: To skip the CMC configuration navigate to the ‘X’ icon and then press the center button. 3. If you are asked to select an appropriate network speed, select a network speed (Auto (1Gb), 10Mb, or ...
Page 33
Yes: Select the check icon then press the center button. You can also configure i DRAC from the CMC web interface. 12. On the Protocol panel, select the IP type that you want to use for the servers: I...
Page 34
to automatically deploy the server using the previously-configured network settings policies. If you do not want to apply the i DRAC network settings to newly-installed servers, select the ‘X’ icon an...
Page 35
Interface Description View alerts and CMC IP. Set DHCP. Configure CMC static IP settings. Telnet Provides command line access to CMC through the network. The RACADM command line interface and the conn...
Page 36
Interface Description For client connection using Microsoft Win RM, the minimum required version is 2.0. For more information, refer to the Microsoft article, <support.microsoft.com/kb/968929>. ...
Page 37
Setting Date and Time on CMC Using CMC Web Interface To set the date and time on CMC: 1. In the left pane, click Chassis Overview → Setup → Date/Time. 2. To synchronize the date and time with a Networ...
Page 38
switch-1 cmc-active and <led State> specifies whether or not the LED should blink. Configuration options: 0 — not blinking (default) 1 — blinking racadm raid <operation> <component FQDD...
Page 39
The Log in Security page is displayed. 3. To enable the user blocking or IP blocking feature, in the Login Lockout Policy section, select Lockout by User Name or Lockout by IP Address (IPV4) . The opt...
Page 40
Remove the network cable from the active CMC. Remove the active CMC from the chassis. Initiate a CMC firmware flash on the active CMC. Have an active CMC that is no longer functional. NOTE: In the eve...