# A B C D E F G H I J K L M N O P Q R S T U V W X Y Z

Industrial Grade 09 COMPUTER ELECTRONICS Owner's Manual

Summary

The GPI Industrial Grade Computer Electronics is a high-reliability, processor-based flow meter designed for measuring liquids in industrial settings. This comprehensive owner's manual provides detailed guidance on every aspect of operation, covering installation procedures, user configuration, calibration, and troubleshooting. It is essential reading for operators seeking to ensure safe, efficient, and accurate fluid measurement while maintaining the integrity of their specialized flow system setup.

📄 Preview PAGE OF 16

Page 1 Text Content

Industrial Grade 09 COMPUTER ELECTRONICS Owner’s Manual

Computer Electronics shown with 1 inch and 2 inch Turbine Housings which are sold separately.

5252 East 36th Street North Wichita, KS USA 67220-3205 TEL: 316-686-7361 FAX: 316-686-6746

“A Great la ins Ventures Subsid iary”

www.gpi.net 1-888-996-3837

Rev. D 920709-0508/06

Page Summary Contents For Industrial Grade 09 COMPUTER ELECTRONICS Owner's Manual

Page 1 Industrial Grade 09 COMPUTER ELECTRONICS Owner’s Manual Computer Electronics shown with 1 inch and 2 inch Turbine Housings which are sold separately. 5252 East 36th Street North Wichita, KS USA 67220-...
Page 2 To the owner . . TABLE OF CONTENTS Congratulations on receiving your GPI Industrial Grade Computer Electronics. We General Information are pleased to provide you with a product de- signed to give you ...
Page 3 2. When measuring flammable liquids, ob- If you ordered your computer separately from serve precautions against fire or explosion. your turbine, simply mount the computer on the turbine with the four ...
Page 4 The Cumulative totalizer register is labeled OPERATIONS as TOTAL 1 LOCKED indicating that it can- not be manually zeroed (See Figure 2). The All operations are reflected in the LCD read- Cumulative to...
Page 5 Figure 3 every five seconds, so the first reading after flow starts or changes and the last reading after flow stops or changes will not be cor- rect. This is normal. Figure 4 The “field” calibration ...
Page 6 Field Calibration of 1-1/2" and 2" meters be Make sure you meet the meter’s minimum completed with a combination of volume and flowrate requirements. weight using fine resolution scales. 1/2...
Page 7 Your Actions Notes 5. Start your pumping system so that fluid flows When the computer displays a non- through the meter. The display will stop blinking “run 01” message, it is blinking and show the “r...
Page 8 Dispense-Display Field Calibration Procedures - cont’d. Your Actions Notes 10. To end calibration, press and hold both After you release the buttons, the buttons for about 3 seconds until you see the ...
Page 9 computer’s long-term memory and will not Replace Batteries be lost either in OFF mode or during battery 1. Remove the corner screws from the change. meter face and lift the computer electron- ics from...
Page 10 TROUBLESHOOTING Symptom Probable Cause Corrective Action Meter is not 1. Field Calibration not per- Field calibrate again or select Factory accurate formed properly Calibration. 2. Factory Calibration...
Page 11 Symptom Probable Cause Corrective Action Cannot get meter 1. Factory Calibration Hold down CALIBRATE and push and into field calibra- (PRESET) curve active release DISPLAY until PRESET flag tion goes ...
Page 12 Computer Electronics Terminal Connections J-1 Reset Programming interfaces. Not accessible to user. J-2 Pulse Signal Output This supplies a high-level amplified open collector signal. Output will with...
Page 13 CAUTION: Do not return computer electron- PARTS ics or meters without specific authority from the GPI Customer Service Depart- The factory, when provided with model num- ment. Due to strict regulation...
Page 14 Copy the information located on the Turbine housing. This information will be required by Customer Service. Model No: Serial No: Distributor Name: Distributor Phone Number:
Page 15 Declaration of Conformity Manufacturer’s Name: Great Plains Industries, Inc. Manufacturer’s Address: 5252 East 36th Street North Wichita, KS USA 67220-3205 Declares, that the product: Product Name: El...
Page 16 Limited Warranty Policy Great Plains Industries, Inc. 5252 E. 36th Street North, Wichita, KS USA 67220-3205, hereby provides a limited warranty against defects in material and workmanship on all produ...

Manual Details

Brand Electronics
Pages 16
File Size 196.85 KB
Published June 03, 2026
49 views

Enter the captcha to get the download link:

captcha

Frequently Asked Questions

What must I check before tightening screws on the turbine assembly?

When handling hazardous liquids, ensure the O-ring ways are fully seated before tightening the screws.

Is this equipment compatible with all liquid types?

No. It is approved to handle components only from GPI's liquid metering system prior to installation and use.

What capacity does the computer display have?

It displays information on a large 6-digit LCD readout with two-point floating decimal for totals up to 999,999.

When is the product warranty voided?

The warranty will not apply if the product has been altered or modified outside of authorized representatives, or misused.