# A B C D E F G H I J K L M N O P Q R S T U V W X Y Z

Dell iDRAC9 Version 5.10.30.00 Release Notes

Summary

iDRAC9 Version 5.10.30.00 Release Notes (June 2022, Rev. A00). This firmware release adds support for new PowerEdge storage controllers and basic Titanium PSU support. Features Secured Component Verification (SCV) v1.5. Minimum upgrade path requires firmware v3.30.30.30 first. Includes previous versions list, new features, fixes, deprecated features, known issues, environment requirements, and iDRAC firmware update instructions using Lifecycle Controller Remote Services.

📄 Preview 📖 Table of Contents Contents PAGE OF 29

Page 1 Text Content

Rev. A00 June 2022

i DRAC9 Version 5.10.30.00 Release Notes

Release Summary Topics: Previous Versions New and enhanced features Fixes Deprecated features Known issues — To be fixed in future releases Important notes Limitations Environment and System Requirements Updating i DRAC firmware Lifecycle Controller (LC) Remote Services — client tools Resources and support Where to Get Help This release adds support for new generation of Power Edge storage controllers and basic support for Titanium Power Supply Units(PSU), along with fixes that improve i DRAC stability.

Release date June 2022

Priority and recommendations Recommended: Dell Technologies recommends applying this update during your next scheduled update cycle. The update contains feature enhancements or changes that will help keep your system software current and compatible with other system modules (firmware, BIOS, drivers, and software).

Minimum version Updating i DRAC firmware from a previous version, such as 3.2x, 3.1x, 3.0x to this version is not supported. Update the firmware to version 3.30.30.30 first, and then update to this version. NOTE: For details about the previous releases, if applicable, or to determine the most recent release for your platform, and for latest documentation version, see KB article SLN308699 available at https://www.dell.com/support/article/sln308699.

Previous Versions 4.40.00.00 4.40.10.00

Release Summary

Page Summary Contents For Dell iDRAC9 Version 5.10.30.00 Release Notes

Page 1 Rev. A00 June 2022 i DRAC9 Version 5.10.30.00 Release Notes Release Summary Topics: Previous Versions New and enhanced features Fixes Deprecated features Known issues — To be fixed in future releases ...
Page 2 New and enhanced features i DRAC firmware Support for Secured Component Verification (SCV) version 1.5 Hardware Basic support for Titanium PSUs enabling Power Edge servers to be powered on with the ne...
Page 3 219889: Lifecycle logs reporting Intel adapter port flapping issue. 221339, 221823: i DRAC reports incorrect events for removal and reinstallation of system fans in SEL and Lifecycle (LC) logs on syst...
Page 4 Deprecated*- No longer being updated or new features added. Removed**- Code has been removed, this feature is no longer functional. To be Removed***- Expected to be removed from i DRAC code in an upco...
Page 5 Table 6. Probe name for GPU displayed incorrectly (continued) Systems All systems supported by this release. Affected Tracking number Table 7. Sleds not powering on after a PSU firmware update Descrip...
Page 6 Table 12. i DRAC time fails to synchronize when Server Configuration Profile is imported with SNTP settings Description i DRAC time will not synchronize when Server Configuration Profile was exported ...
Page 7 Table 17. SCP import failing (continued) Workaround Update the i DRAC version of the system exporting SCP file to i DRAC version 5.00.20.00 and the try exporting the file again. Systems All systems su...
Page 8 Networking and IO Table 23. Unable to add i DRAC Static IP Description After setting i Drac static IP using IPV4 group (IPv4.1.Address, IPv4.1.Gateway,IPv4.1.Netmask) using Redfish or RACADM interface...
Page 9 Table 28. Boot mode error during OS deployment Description While deploying OS using LC UI, if the current boot mode is set to UEFI and you change the boot mode to BIOS and click Finish on the last LC ...
Page 10 Table 33. Service Validator reporting errors for Redfish API services (continued) Systems All systems supported by this release. Affected Tracking number Table 34. Performing GET with Top query parame...
Page 11 Table 39. Get operation not displaying model or serial number for PCIe devices (continued) Workaround N/A Systems All systems supported by this release. Affected Tracking number Storage and storage co...
Page 12 Miscellaneous Table 44. i DRAC HII displaying an additional backplane Description Information about an extra backplane may be displayed in i DRAC HII. Workaround N/A Systems All systems supported by t...
Page 13 Table 50. Webserver restarts after remote presence port number is updated Description Changing the Remote Presence Port number through virtual console settings page may cause a system restart, further...
Page 14 9. While performing a firmware update or rollback through Life Cycle controller(LC) GUI, the component information displayed in the table listing the available updates may be truncated if it exceeds t...
Page 15 32. Key sharing between multiple i DRACs is supported and can be configured on the SEKM server. Key sharing can be done if all the i DRACs are part of the same SEKM group and all keys are assigned to ...
Page 16 9. Fibre-channel NIC cards with dual or four ports are displayed as a single port card in LC. However, all ports are updated when a firmware update is performed. 10. If SMBv2 share fails in Lifecycle ...
Page 17 However, if a server AC power cycle or i DRAC reboot is performed, the OEMDRV drive is automatically detached. 5. CPLD firmware update has no impact on Trusted Platform Module enablement. 6. Ensure th...
Page 18 Miscellaneous 1. Virtual console may not launch after Java is updated to the latest version. Ensure that TLS protocol is set to version 1.2 or above. 2. Virtual Console and Virtual media may not funct...
Page 19 BIOS and UEFI 1. When setting the i DRAC Service Module (i SM) monitoring attributes from the web interface, if the BIOS watchdog timer is enabled, an error may be displayed but the attributes are set...
Page 20 8. When setting the i DRAC Service Module (i SM) monitoring attributes from the web interface, if the BIOS watchdog timer is enabled, an error may be displayed but the attributes are set. To avoid the...
Page 21 3. Windows operating system deployment may intermittently fail with the following error message: A required CD/DVD drive device driver is missing. If you have a driver floppy disk, CD, DVD, or USB dri...
Page 22 Firmware and driver update 1. CMC server component update does not support the i DRAC9 firmware packages. Use i DRAC GUI, RACADM interface, or Open Manage Enterprise Modular to perform any out-of-band...
Page 23 i DRAC Secure Enterprise Key Manager(SEKM)—Only available on systems that are mentioned in the Supported Systems section BMC – Available only on Dell Power Edge C series servers. NOTE: i DRAC Secure E...
Page 24 Power Edge XE7420 Power Edge XE7440 Power Edge XE8545 Power Edge XR2 Power Edge XR11 Power Edge XR12 DCS1610 DCS9650 DCS9660 DCS9670 DCS9690 DSS8440 DSS9600 DSS9620 DSS9630 Vx Rail G560 Dell XC Core X...
Page 25 OEMR R740xd2 OEMR T140 OEMR T150 OEMR T340 OEMR T440 OEMR T550 OEMR T640 OEMR XE R350 OEMR XR11 OEMR XR12 Supported managed server operating systems and hypervisors Microsoft Windows Server 2022 Essen...
Page 26 Open Source tools Open JDK 8u202 Adopt Open JDK You may utilize an open source version of Adopt Open JDK or Open JDK (“Adopt Open JDK”) subject to the terms and conditions of the Adopt Open JDK commun...
Page 27 1. Extract the self-extracting installation package to the management station. 2. Access the i DRAC web interface using a supported web browser. 3. Log in as an administrator. 4. Click Maintenance &gt...
Page 28 Accessing documents using the product search 1. Go to https://www.dell.com/support. 2. In the Enter a Service Tag, Serial Number... search box, type the product name. For example, Power Edge or i DRAC...
Page 29 Copyright © 2022 Dell Inc. or its subsidiaries. All rights reserved. Dell Technologies, Dell, and other trademarks are trademarks of Dell Inc. or its subsidiaries. Other trademarks may be trademarks o...

Manual Details

Brand Dell
Pages 29
File Size 267.27 KB
Published July 02, 2026
3 views

Enter the captcha to get the download link:

captcha

Frequently Asked Questions

What is required to use Titanium Power Supply Units (PSUs)?

You must upgrade your iDRAC firmware to version 5.10.30.00 or a later version before installing the PSU.

Can I update my iDRAC firmware from older versions like 3.2x?

No, updating from versions 3.2x, 3.1x, or 3.0x is not supported; you must first upgrade to version 3.30.30.30.

What specific storage components are newly supported?

The update adds support for PERC H350 MM, HBA 350i MM, Samsung PM9A3 NVMe drives, and Kioxia CD7 U.2 SSDs.

Are there fixes for CPU throttling issues on PowerEdge servers?

Yes, the release includes fixes addressing CPU throttling on devices like the PowerEdge R650 and after AMD CPU configuration changes.