# A B C D E F G H I J K L M N O P Q R S T U V W X Y Z

Dell iDRAC9 Version 5.10.00.00 Release Notes

Summary

This document contains release notes for iDRAC9 Version 5.10.00.00. It details new and enhanced features including TLS v1.3 support, rebootless NVMe drive updates, PSU redundancy API management, and new telemetry triggers. The release notes cover automation API and CLI improvements, Redfish protocol updates, security enhancements, known issues, limitations, and system requirements. Targeted at system administrators and IT professionals who manage Dell PowerEdge servers and need to stay current with iDRAC firmware capabilities.

📄 Preview 📖 Table of Contents Contents PAGE OF 28

Page 1 Text Content

Rev. A00 December 2021

i DRAC9 Version 5.10.00.00 Release Notes

Release Summary Topics: Previous Versions New and enhanced features Fixes Deprecated features Known issues — To be fixed in future releases Important notes Limitations Environment and System Requirements Updating i DRAC firmware Lifecycle Controller (LC) Remote Services — client tools Resources and support Where to Get Help This release adds support for TLS v1.3, rebootless updates for NVME drives, PSU redundancy management through API, new triggers for telemetry, and fixes that improve i DRAC stability.

Release date December 2021

Priority and recommendations Recommended: Dell Technologies recommends applying this update during your next scheduled update cycle. The update contains feature enhancements or changes that will help keep your system software current and compatible with other system modules (firmware, BIOS, drivers, and software).

Minimum version Updating i DRAC firmware from a previous version, such as 3.2x, 3.1x, 3.0x to this version is not supported. Update the firmware to version 3.30.30.30 first, and then update to this version. NOTE: For details about the previous releases, if applicable, or to determine the most recent release for your platform, and for latest documentation version, see KB article SLN308699 available at https://www.dell.com/support/article/sln308699.

Previous Versions 4.40.00.00 4.40.10.00

Release Summary

Page Summary Contents For Dell iDRAC9 Version 5.10.00.00 Release Notes

Page 1 Rev. A00 December 2021 i DRAC9 Version 5.10.00.00 Release Notes Release Summary Topics: Previous Versions New and enhanced features Fixes Deprecated features Known issues — To be fixed in future relea...
Page 2 New and enhanced features i DRAC firmware Rebootless updates for NVMe drive (SK-Hynix PE8010 and later versions). Disk "warning" in System Event Log (SEL). Support for 15 users in LDAP group...
Page 3 Automation—API and CLI 202798: Telemetry Service Redfish URI displaying removed components. 194894: RACADM autocomplete action not working on First NVMe Target and Second NVMe Tgt. 206915: RACADM fail...
Page 4 Known issues — To be fixed in future releases Hardware Table 2. CPU PPIN in Hardware inventory in IDRAC GUI shows as “Not Supported” Description CPU PPIN in Hardware inventory in IDRAC GUI shows as &q...
Page 5 Table 7. Sleds not powering on after a PSU firmware update Description After performing a PSU firmware update through DUP method, only one sled powers on automatically while others remain powered off....
Page 6 Table 13. i DRAC time fails to synchronize when Server Configuration Profile is imported with SNTP settings Description i DRAC time will not synchronize when Server Configuration Profile was exported ...
Page 7 Table 18. SEL events may not be correctly displayed in the earlier versions of i DRAC Description New SEL events were introduced in i DRAC versions 4.4x. If i DRAC is rolled back to an earlier version...
Page 8 Table 23. Unable to add i DRAC Static IP (continued) Systems All systems supported by this release. Affected Tracking number Table 24. NIC or FC device slot listed in hardware inventory even when disa...
Page 9 Automation — API and CLI Table 28. GPU temp sensor information not displayed in IPMI Description GPU temperature sensor may not display the relevant sensor information while using IPMI tool. Workaroun...
Page 10 Table 33. Performing GET method on chassis PCIe slots displays all PCIe slots (continued) Tracking number Table 34. Uploaded firmware link not available in Software Images property Description While p...
Page 11 Table 39. Cryptographic erase fails on the root port attached drive (continued) Workaround Perform Racreset to recover the server from the issue state and then try the operation again. Systems All sys...
Page 12 Table 44. Virtual console display in i DRAC GUI is blurred (continued) Systems All systems supported by this release. Affected Tracking number Table 45. Few Virtual Keyboard keys not working for other...
Page 13 i DRAC firmware 1. To apply a firmware update that is scheduled and awaiting a host reboot, ensure that you perform a cold reboot instead of a warm reboot. 2. For catalog updates through downloads.del...
Page 14 23. This note is applicable only to Power Edge M640 and FC640. After the BIOS recovery operation, host may not turn on. To recover from this condition, do a virtual/physical reseat operation of the bl...
Page 15 11. If you see i SM0050 event in LC log, then ensure that you update the i DRAC Service Module (i SM) to version 3.4 or to a TLS-capable i SM. i SM without TLS capability is not supported on i DRAC fi...
Page 16 10. Performing GET method on steps only shows the next scheduled jobs and not the completed jobs. 11. Performing Redfish Patch method on Read-Only property for Power Control resource returns a 200 sta...
Page 17 9. The option to enable or disable the disk cache policy for SWRAID controllers are supported only on SWRAID controller driver version 4.1.0-0025 or later. 10. If any of the NVMe drives report a 'Fail...
Page 18 Automation — API and CLI 1. Sometimes, when using WSMan, an Internal SSL Error is reported and the WSMan command fails. If this issue occurs, retry the command. 2. Using WSMan, the attribute LCD.Chass...
Page 19 Monitoring and alerting 1. In certain cases, Group Manager Jobs view may not show a detailed error message for a member i DRAC job. For more information about the failure, review the job execution det...
Page 20 On the Network Settings page of Lifecycle Controller GUI, the IP Address Source for both IPv4 and IPv6 is either DHCP or Static and DHCP is selected by default. So, even if you want to use only one ve...
Page 21 b. Ensure that CSIOR is enabled before turning off the system. c. Use the following RACADM command: racadm serveraction powercycle 5. Few legacy drives do not support the SMART ID #245 "Remaining...
Page 22 11. When accessing i DRAC through a Safari web browser version 14.0.3 and later versions, if a page refresh is attempted using the browser refresh option, then the i DRAC session may get cleared and y...
Page 23 Power Edge R6415 Power Edge R6515 Power Edge R6525 Power Edge R7415 Power Edge R7425 Power Edge R7515 Power Edge R7525 Power Edge T140 Power Edge T150 Power Edge T340 Power Edge T350 Power Edge T440 P...
Page 24 OEMR R650xs OEMR R6415 OEMR R6515 OEMR R6525 OEMR R750 OEMR R750xa OEMR R750xs OEMR R7525 OEMR R7515 OEMR R7415 OEMR R7425 OEMR R740 OEMR R840 OEMR R940 OEMR R940XA OEMR R740xd OEMR R740xd2 OEMR T140 ...
Page 25 Supported web browsers Microsoft Internet Explorer 11 Microsoft EDGE Safari 13.1.2 Mozilla Firefox 81 Mozilla Firefox 80 Google Chrome 84 Google Chrome 83 Supported software Java Java - Oracle version...
Page 26 1. Go to https://www.dell.com/support. 2. In the Enter a Service Tag, Serial Number... field, type the Service Tag or the model number of your server, and press Enter or click the search icon. 3. On t...
Page 27 Accessing documents using direct links You can directly access the documents using the following links: Table 48. Direct links for documents URL Product https://www.dell.com/idracmanuals i DRAC and Li...
Page 28 Copyright © 2021 Dell Inc. or its subsidiaries. All rights reserved. Dell, EMC, and other trademarks are trademarks of Dell Inc. or its subsidiaries. Other trademarks may be trademarks of their respec...

Manual Details

Brand Dell
Pages 28
File Size 262.20 KB
Published June 24, 2026
9 views

Enter the captcha to get the download link:

captcha

Frequently Asked Questions

Can I update iDRAC firmware directly from version 3.x to 5.10.00.00?

No. You must update to version 3.30.30.30 first before upgrading to 5.10.00.00.

What security updates were included in the 5.10.00.00 release?

The update adds support for TLS v1.3 and iDRAC Local Key Management (iLKM).

Which features are deprecated in iDRAC9 for PowerEdge R6xx and R4xx servers?

VM CLI, vFlash, Backup and Restore, RBAP and Simple Identity profiles, WSMan, DCIM_account profile, Telnet, TLS 1.0, and Java/ActiveX plugins are all deprecated or removed.