Agilent Measurement of Macro and Trace Elements in Plant Digests Using the 7500c ICP-MS System
Summary
The Agilent 7500c ICP-MS system is a professional, high-performance instrument designed for the precise measurement of major, minor, and trace elements. This resource describes its application in complex matrices, such as plant digests, providing a robust solution for nutritional analysis where low concentrations require extreme accuracy. Ideal for researchers and professionals in food science, public health, and agribusiness, it enables scientists to quantify essential micronutrients required for human diet planning, ensuring reliable and comprehensive results even from challenging samples.
Page 1 Text Content
Measurement of Macro and Trace Elements in Plant Digests Using the 7500c ICP-MS System Application
Author grains such as wheat and rice is resulting in a nutritionally poor diet. Micronutrient [1] malnutri-
Kazuo Yamanaka
tion is an identified problem that has coincided
Agilent Technologies with the rapid adoption of modern cereal cropping Nakacho 1-15-5 systems. Profitable and sustainable agriculture Musashino-shi depends on the understanding of the nutrients
Tokyo 180-8543 required and available for plant growth, as well as Japan the nutrients for a balanced human diet.
Fred Fryer “World food production will need to double over Agilent Technologies the next 30 years to keep pace with increasing
12/2 Eden Park Drive, demands from both industrialized and rapidly North Ryde NSW 2113 developing countries. As well as the need to Australia increase production, there will be an increase in demand for higher quality and healthier food prod- ucts as developing countries become more
Abstract affluent.”
Inductively coupled plasma mass spectrometry is a pow- Taken from the Commonwealth Scientific and erful tool for the investigation of many materials. The Industrial Research Organisation (CSIRO) website: Agilent 7500c with Octopole Reaction System was used to http://www.csiro.gov.au (select: analyze major, minor and trace elements in two standard Agribusiness/Field Crops/Field Crops & Australia)
reference plant materials. The data obtained using the
Human dietary micronutrients are required by
7500c is compared to the certificate reference values and
humans in very small amounts. They include at
to results that were generated using inductively coupled
least 14 trace elements (As, B, Cr, Cu, F, I, Fe, Mn,
plasma optical emission spectroscopy. Results for all ele-
Mo, Ni, Se, Si, V, Zn) as well as 13 vitamins (thi-
ments obtained using the 7500c agree with the
amin, riboflavin, niacin, pantothenic acid, biotin,
certified values.
folic acid, vitamins B6, B12, C, A, D, E, K)
Introduction The recommended daily intake of the micronutri- ent trace elements is of the order of:
The reliable measurement of trace elements in food
mg per day for B, Cu, F, Fe, Mn, Zn
is becoming more important as information is
µg per day for As, Cr, I, Mo, Ni, Se, Si, V
revealing that over-dependence on processed
Page Summary Contents For Agilent Measurement of Macro and Trace Elements in Plant Digests Using the 7500c ICP-MS System
Manual Details
| Brand | Measurement |
|---|---|
| Pages | 6 |
| File Size | 384.87 KB |
| Published | June 03, 2026 |
Enter the captcha to get the download link:
Frequently Asked Questions
How does the 7500c ICP-MS reduce spectral interference during analysis?
It uses an Octopole Reaction System (ORS) to remove interferences by reacting a gas with the interference or preventing species from entering the analyzer stage.
What types of matrices are suitable for investigation using this instrument?
It is specifically designed for complex matrices such as plant and food digests, making it useful in areas like nutritional studies.
What range of elements and compounds can be measured by the 7500c system?
It analyzes major, minor, and trace elements, including 14 specified trace elements (e.g., As, Cu, Zn) and 13 vitamins.
How sensitive is the instrument when measuring difficult traces?
The 7500c can accurately quantify analytes at extremely low levels, achieving results even <10 ppt or sub-ppb levels.