# A B C D E F G H I J K L M N O P Q R S T U V W X Y Z

ABB White Paper - ABB Measurement & Analytics Monitoring Cement Plant Stack Emissions Using FTIR

Summary

The ABB FTIR CEMS analyzer provides precise, continuous monitoring of stack emissions in cement manufacturing facilities. This hot/wet extractive system utilizes high-resolution spectroscopy to track up to fifteen gaseous pollutants, including HCl, SO₂, NOx, and CO₂. The accompanying manual validates the system's performance through extensive field trials, demonstrating its ability to meet stringent EPA certification and QA requirements under varied operating conditions for plant operators needing reliable compliance assurance.

📄 Preview PAGE OF 8

Page 1 Text Content

B M SU EM ENT & A LY TI S | ITE PA PER

Monitoring cement plant stack emissions using FTIR

ABB FTIR CEMS analyzer successfully monitors cement plant stack emissions in extensive field study

Measurement made easy

ACF5000 FTIR Continuous Emission Monitoring Introduction System (CEMS)

A major U.S. cement manufacturing facility

completed a five-month field trial of the ABB

filter

ACF5000 hot/wet extractive FTIR Continuous

Coal bin

Emission Monitoring System (CEMS) in August 2015.

Coal mill

The trial primarily tested the system’s capabilities to satisfy EPA HCl emission monitoring

Measuring

requirements. Secondarily, it checked how well the

point

system monitored other regulated emission Raw mill

pollutants (SO2, NOx, CO, CO2) under relevant EPA Secondary firing

performance specifications and QA requirements

Primary firing

and examined the analyzer’s performance in

Rotary kiln

monitoring non-regulatory parameters of interest such as ammonia, formaldehyde, and methane.

Lastly, the tests included monitoring during different in-line raw mill operating conditions, which can contribute to significant variability in emissions. Figure 1 Layout of typical cement plant and measurement location

Page Summary Contents For ABB White Paper - ABB Measurement & Analytics Monitoring Cement Plant Stack Emissions Using FTIR

Page 1 B M SU EM ENT & A LY TI S | ITE PA PER Monitoring cement plant stack emissions using FTIR ABB FTIR CEMS analyzer successfully monitors cement plant stack emissions in extensive field study Measure...
Page 2 ITO G CE NT PL NT S TACK E S U G F TI R | P/A LY TI /0 2- EN Re v. The ABB FTIR analyzer system The trial evaluated the ACF5000 FTIR CEMS manufactured The use of the air injector allows direct connect...
Page 3 ITO G CE NT PL NT S TACK E S U G F TI R | P/A LY TI /0 2- EN Re v. 3M Assessment criteria The main trial objectives concerned the analyzer’s performance in achieving the following assessment criteria....
Page 4 ITO G CE NT PL NT S TACK E S U G F TI R | P/A LY TI /0 2- EN Re v. Results with in-line raw mills in Results for different operating operation conditions The ABB ACF5000 FTIR CEMS provided accurate Li...
Page 5 ITO G CE NT PL NT S TACK E S U G F TI R | P/A LY TI /0 2- EN Re v. 5M Vo l% Vo l% Additional field study results The ABB ACF5000 FTIR CEMS operation proved to be highly This field study exposed discre...
Page 6 ITO G CE NT PL NT S TACK E S U G F TI R | P/A LY TI /0 2- EN Re v. I, Vo l% 2O System response time tests No specific system response time must be met in order to comply with PS18, although the time t...
Page 7 ITO G CE NT PL NT S TACK E S U G F TI R | P/A LY TI /0 2- EN Re v. 7M Conclusions In summary, the ABB ACF5000 FTIR Continuous Emission Monitoring System completed its commissioning and operated for se...
Page 8 ABB Limited Measurement & Analytics Howard Road St. Neots Cambridgeshire PE19 8EU UK Tel: +44 (0)870 600 6122 Fax: +44 (0)1480 213 339 Email: [email protected] ABB Inc. Measurement & ...