This advanced, vandal-resistant IP Dome Camera offers high-definition surveillance with superior image clarity and field coverage enhancement. This manual provides comprehensive instructions for professional installation, including proper sealing of mounting and piping holes, detailed LAN and alarm cable connections, and precise focus adjustment techniques. Essential setup guides are also available on the supplied CD-ROM. It is ideal for security professionals and system integrators looking to implement reliable, high-performance surveillance systems.

📄 Preview PAGE OF 2

Page 1 Text Content

Cable Connection Processes after connection For safety reasons, turn on the power only after all the connections are completed. Fill up the piping hole and mounting hole with sealant and insert the silica gel. Roughly adjust the focus When power is supplied to the camera, the [STATUS] indicator lights up. The indicator lights up in orange during Lift the focus adjust gear knob, and place the catch into B in the diagram startup and turns green when startup is complete. The gear is disengaged.

FIXED IP DOME CAMERA (Vandal Resistant)

1 Use sealant (GE silicon) to fill up the mounting holes (x2) to which Note:

FIXED MEGAPIXEL IP DOME CAMERA (Vandal Resistant)

If the gear is moved outwards from B, the shaft of the gear may shift. For details on how

the piping hole and screws are mounted

to return the gear to the original position, refer to ( A [INSTRUCTIONS (Installation)]) in READ ME FIRSTVN-V225VPU 1 Connect the alarm cable the supplied CD-ROM.

Note: Connect the alarm cable to an external device, such as a sensor or buzzer. Make sure the holes are completely sealed up. Water or moisture may seep in and fog up the

Loosen the fastening screw of the focus adjustment ring, move it to the left and

lens and dome cover.

right to adjust the focus.

VN-X235VPU Alarm cable to use (Recommended shield cable)

LST0849-001B

Length of 50 m or shorter Fine adjust the focus UL1007, UL1015 or equivalent products 2 Insert the silica gel (provided)

VN-X235VPU is a high definition surveillance camera that uses high resolution CCD sensors with 4 times Press the [RESET] button for more than 2 seconds but less than 5 seconds.

AWG#22 to AWG#18 or equivalent products

the pixel count of VN-V225VPU. The camera enters the focus adjust mode and the [STATUS] indicator blinks in green

Note:

and orange alternately.

Thank you for purchasing this JVC product. 2 Connect to audio cable (Recommended shield cable) Please make sure that rain does not seep into this unit when mounting on rainy days.

The image is sharpened with the opening of the lens iris.

Before operating this unit, please read the instructions carefully to ensure the best possible performance. Be sure to use the silica gel (provided). Failure to do so may fog up the camera lens and dome cover.

The center of the image is enlarged. (VN-X235VPU only)

If field angle is not adjusted immediately after mounting the camera, insert the silica gel (provided) after After adjusting the focus, press the [RESET] button for more than 2 seconds but less

3 Connect the LAN cable

This manual contains the basic instructions for using this unit. adjustment. The silica gel (provided) will lose its effectiveness if it is exposed to the air for a long time. than 5 seconds to release the focus adjust mode.

To use the Po E power supply, connect to a Po E-compatible device and supply the power from the

Please refer to [INSTRUCTIONS (Setting)] (pdf) and [INSTRUCTIONS (Installation)] (pdf) in the CD-ROM Shoot the subject

LAN cable.

supplied with this product for description on the detailed usage of this unit. Fine adjust the focus

Note:

For the latest information, please refer to the AREADMEB file in the CD-ROM supplied with this product. Return the catch to A in the diagram, and then rotate the knob to adjust the focus to the

When using a heater unit (sold separately: KA-ZH215U), Po E power supply does not work

The supplied CD-ROM includes [INSTRUCTIONS (Setting)] (pdf), [INSTRUCTIONS (Installation)] optimum position.

for the heater unit (KA-ZH215U). Be sure to use an AC 24 V power supply.

(pdf), [API Guide] (pdf), [VSIP Guide] (pdf) and [Search tool], [White Spot Correction Tool]. Rotate the focus adjust gear knob about one base pitch in the direction of the arrow

in the diagram.

How to read this READ ME FIRST Connecting to HUB : Use a straight cable

This is to correct the focus shift when mounting the dome cover.

Connecting to a computer : Use a cross cable

JVC holds the copyright to this manual. Any part or all of this manual may not be reproduced without prior consent

Hold the dome cover over the lens and check the focus

from the company.

LAN cable to use

Windows is a registered trademark of Microsoft Corporation in the U.S.

Hold and press the focus adjust gear between your fingers in the

Product names of other companies described in this manual are trademarks or registered trademarks of the STP (Recommended shield cable)

Space for inserting direction of the arrows in the diagram, and tighten the fastening

respective companies. Symbols such as ,  and  are omitted in this manual. Length of 100 m or shorter

the silica gel screw of the focus adjustment ring

Design, specifications and other contents described in this manual are subject to change for improvements without

Category 5 and above

prior notice.

Set the [MONITOR OUT] selector switch to AOFFB, then press the

4 Connect the power cable [RESET] button shortly (less than 2 seconds)

The latest version

Power can be supplied to this unit either by connecting to an AC 24 V power supply or using The camera restarts, and the focus assist mode is released.

Please visit V.NETWORKS web site to check the latest firmware at

Sealant

Po E. (To use Po E A [3 Connect the LAN cable])

http://www.jvc-victor.co.jp/english/products-e.html (GE silicon)

Note:

(The latest firmware can be found on V.NETWORKS B download page)

The power supply cable includes cable of the same color as the alarm cable. Check properly before Knob Zoom adjustment ring Focus adjustment ring

This illustration is for the ABCatch

connecting. purpose of explanation, and

Installation

Make sure that power is supplied using only one of the above methods at any one time. Connecting does not represent the actual camera.

simultaneously using the power cable and to Po E via a LAN cable may cause the camera to break down or malfunction.

By default the IP addresses of all the cameras are set to 192.168.0.2. If the power of multiple Silica gel (Provided)

Mounting the Camera

Lug plate

cameras within the same LAN environment are turned on at the same time, the IP addresses of the cameras overlap, thus preventing proper access. As such, make sure to turn on the power of the cameras one by one and set the IP addresses such that there is no overlapping.

Setting Up the Camera

Type of cable

Type Color Signal Name

1 Remove the dome cover with the wrench provided (Screws x3) Alarm cable Black Red Alarm input 1

(shielded cable)

2 Grab the inner dome and remove it from the catches (x3) Brown Alarm input 2

Adjusting Images

Focus adjust gear

Orange Alarm output 1

When the camera is mounted, adjust the image settings while looking at the actual image.

Yellow Alarm output 2 Before touching the body of the camera, make sure to touch the metal surface of the [MONITOR] terminal to Knob Catch AB

Inner dome discharge the static electricity from your body. The static electricity may cause the camera to malfunction.

Black GND

Audio cable Brown White MIKE IN

Wrench (provided)

(shielded cable)

Yellow GND 1 Connect the [MONITOR] terminal to the test monitor Black White LINE OUT

(shielded cable) 2 Set the [MONITOR OUT] selector switch to ANB or APB, turn on the

cover Fall Yellow GND

prevention Catches power or press and hold the [RESET] button for less than 2 seconds

Power cable Red (unshielded cable) AC 24 V Power Supply

wire (x3)

Camera The camera reboots. (approximately 1 minute)

(not Black (unshielded cable) One base pitch

removable) During the restart, the [STATUS] indicator lights up in orange. Power cable Connection distance when using 2-core VVF cable (Reference values) Set to ANB when connecting to a NTSC monitor or set to APB when connecting to a PAL monitor.

Conductor diameter (mm) R1.0 and above R1.6 and above R2.0 and above

3 Adjust the shooting direction of the camera

Maximum connection distance (m)

Adjust the camera for pan, tilt and rotation, and face the camera towards the subject.

Maximum connection distance (m) with Heater (KA-ZH215U)

Pan: ±175

Mounting the Camera

Mount the camera to the ceiling or wall.

Caution

Mounting the Dome Cover

To mount on a wall, perform the same procedures below but replace the word “ceiling” with “wall”.

[MONITOR OUT] selector switch

The rated power of this product is AC 24 V, 50 Hz/60 Hz. Make sure to use it with the correct

[MONITOR] terminal

voltage.

[STATUS] indicator

1 Use the provided template to make a R30 mm (1-1/8 inch) hole in the ceiling. Be sure to use an AC 24 V supply that is insulated from the primary power source.

[RESET] button 1 Mount the inner dome to the catches (x3)

Supplying a power beyond the rated value may result in failures, smoke or fire. If the camera

2 Mount the fall prevention wire that connects the camera to the ceiling. breaks down, turn off the power and contact our service center immediately.

Test monitor Rotation: ±175 Tilt: ±70 2 Mount the dome cover

When a power beyond the rated value is supplied, the internal components may be

Fall prevention wire is not provided. Prepare a wire with due consideration of the length, strength,

damaged even if no abnormality is found on the appearance and operation of the camera. Remove and clean any dust or dirt on the dome cover.

pull factor and material (insulative).

Shooting direction

Please send to your nearest JVC dealer immediately for servicing (charged separately). 75 K

mark Align the base with the position alignment marks (x3) on the dome cover and mount

Unscrew the mounting screw for the fall prevention wire beneath the camera and mount

terminated

Pan center mark the dome cover.

the fall prevention wire.

5 Wind the waterproof tape

Tighten and secure the dome cover fastening screws (x3).

Mount the fall prevention wire to a strong location.

Note: Rotation center 3 Mount the camera to the ceiling mark

For cables that are not used, be sure to wrap the ends individually with insulating tape.

Position alignment mark (x3)

Pull out the cables from the ceiling and the cables from the camera towards the lens as shown, face the (D) mark in the shooting direction, then mount the camera to the ceiling. To mount on a wall, Rotation control (x4)

mount the camera such that the (D) mark is facing upwards. Space for heater

Catches

Screws for mounting the camera are not provided. Use the appropriate type of screws according Memo:

to the material of the location for mounting. When mounting the heater unit (sold Tilt fastening screw

Fall prevention wire

separately: KA-ZH215U), please refer to Memo:

R30 mm (1-1/8 inch) the KA-ZH215U [INSTRUCTIONS].

Rotate both pan and rotation ±175 from the positions aligned with the camera’s shooting Fall prevention wire (not provided) direction mark, pan center mark and rotation center mark. Be sure to hold the rotation control and adjust the rotation without holding the lens section.

1,2,4 After adjusting the field angle, tighten and secure the tilt fastening screw so that the field angle cover

8 mm will not be misaligned.

6 mm and below 10BASE-T/100BASE-TX(Po E) Inner dome Wrench (provided)

Shooting Wind the

Solder welding

2 mm terminal Note:

direction mark or crimping waterproof

R12 mm and below Moving the camera when it has exceeded the adjustment range may cause its performance to

deteriorate.

As the tilt and rotation range of this unit is wide, part of this unit may be reflected in the shooting Note:

Wind the

R4.1_6.5 mm screen depending on the field angle and direction. Check that the silica gel (Provided) has been inserted before mounting the dome cover.

insulation tape

Do not hold the lens section when adjusting the camera direction. The lens section may be Ensure that the dome cover is secured. Insecure mounting may increase humidity, fog up the damaged if you apply force to it. camera or the cover may drop.

R4 mm screw ×2 (not provided)

When the cover is removed again after mounting the dome cover, check the field angle and re-

Note: adjust the focus and field angle if necessary.

Adjust the image size

To mount the camera using electrical box or piping, please refer to (A [INSTRUCTIONS Make sure that the fall prevention wire of the dome cover is not caught between the dome cover

(Installation)]) in the bundled CD-ROM. Loosen the fastening screw of the zoom adjustment ring, move the ring to the left and right to and the base. Otherwise, the anti-dust and waterproof function may not work properly. adjust the image size. After adjusting, fasten the screw with pressing it slightly toward the lens direction (toward the shooting direction).

LAN cable LAN cable stopper (x2)

Continued

Page Summary Contents For JVC VN-V225VPU VN-X235VPU Installation Manual User Guide

Page 1 Cable Connection Processes after connection For safety reasons, turn on the power only after all the connections are completed. Fill up the piping hole and mounting hole with sealant and insert the si...
Page 2 If the active script of the Internet Explorer is disabled, follow the steps below to enable it Setting Select [Trusted sites] under [Tool]-[Internet Options]-[Security]. Upon doing so, the [Sites...] ...

Manual Details

Brand JVC
Pages 2
File Size 2.52 MB
Published May 24, 2026
29 views

Enter the captcha to get the download link:

captcha

Frequently Asked Questions

What safety steps should I take after connecting cables?

After all connections are complete, fill the piping and mounting holes with sealant (GE silicon) and insert the provided silica gel.

How do I adjust the focus on the camera?

Loosen the fastening screw of the focus adjustment ring, move it to the left, and fine-tune the focus using a dedicated knob in or out movements.

What is recommended for connecting alarm/audio cables?

Use shielded cables (such as AWG#22 to AWG#18) and ensure all holes are completely sealed from moisture.

How do I reset the camera's focus adjustment mode?

After adjusting the focus, press the [RESET] button for more than 2 seconds but less than 5 seconds until the camera enters 'focus adjust mode'.