Product Overview and Specifications The Dell Metered Rack PDU distributes power to the devices in the rack. OUTLETS—The Rack PDU has (21) IEC 320-C13 and (6) IEC 320-C19 outlets. POWER CORD—The Rack P...
Page 4
DELLM0003 Environmental Maximum elevation (above MSL) Operating 0 to 3048 m (0 to 10,000 ft) Storage 0 to 15 240 m (0 to 50,000 ft) Temperature Operating 0 to 50°C (32 to 122°F) Storage -15 to 60°C (5...
Page 5
Bloc multiprise Dell Unité de distribution d'alimentation (PDU) DELLM0003 Présentation et caractéristiques du produit Français
Page 6
Présentation et caractéristiques du produit Le bloc multiprise Dell PDU distribue l'alimentation vers les périphériques de la baie. PRISES—Le bloc PDU a (21) prises IEC 320-C13 et (6) prises IEC 320-C...
Page 7
DELLM0003 Environnement Altitude maximale (au dessus du niveau de la mer) 0 à 3.048 m (0 à 10.000 pieds) Fonctionnement 0 à 15.240 m (0 à 50.000 pieds) Entreposage Température Fonctionnement 0 à 50°C ...
Page 8
Bastidor con medidor Dell Unidad de distribución de energía (PDU) DELLM0003 Generalidades y especificaciones del producto Español
Page 9
Generalidades y especificaciones del producto El Bastidor con medidor Dell PDU distribuye energía a los dispositivos del bastidor. TOMACORRIENTES: El Bastidor PDU posee (21) tomacorrientes IEC 320-C13...
Page 10
DELLM0003 Ambiental Elevación máxima (superior al límite máximo tolerado) De operación De 0 a 3048 m (de 0 a 10 000 pies) De almacenamiento De 0 a 15 240 m (de 0 a 50 000 pies) Temperatura De operació...
Page 11
Dell Metered Rack (Stromverteilerleiste) Stromverteilungseinheit (PDU) DELLM0003 Produktübersicht und technische Angaben Deutsch
Page 12
Produktübersicht und technische Angaben Das Dell Metered Rack PDU verteilt Strom an die Geräte im Rack. AUSGÄNGE — Das Rack PDU besitzt (21) IEC 320-C13- und (6) IEC 320-C19-Ausgänge. NETZKABEL — Das ...
Page 13
DELLM0003 Umgebung Max. Erhöhung (über NN) Betrieb 0 bis 3.048 (0 bis 10.000 Fuß) Lagerung 0 bis 15.240 (0 bis 50.000 ft) Temperatur Betrieb 0 bis 50°C (32 bis 122°F) Lagerung -15 bis 60°C (5 bis 140°...
Page 14
Dell Metered Rack ユニット (PDU) DELLM0003
Page 15
DELLM0003 アメリカ: IEC60309-20 Aプラグ、: IEC60309-16 Aプラグ 346–415 VAC ± 10% %&'()*) アメリカ: 20 A (16 A UL (C-UL) ディレーティング); : 16 A 11 k VA 50/60 Hz / 200–240 VAC ± 10% (21) IEC 320-C13 (6) IEC 320-...
Page 16
DELLM0003 %&4`(K4) ab: 0 ~ 3 048 m (0 ~ 10,000 ft) cd: 0 ~ 15 240 m (0 ~ 50,000 ft) f` ab: 0 ~ 50°C (32 ~ 122°F) cd: -15 ~ 60°C (5 ~ 140°F) ab: 5 ~ 95%(hiなし) cd: 5 ~ 95%(hiなし) j0k= UL(C-UL)、TUV-GS...
Page 17
Dell (PDU) DELLM0003
Page 18
DELLM0003 : IEC60309-20 A , : IEC60309-16 A 346~415VAC ± 10% : 20A(16A UL(C-UL) #), : 16A 11k VA 50/60Hz 200~240VAC ± 10% (21) IEC 320-C13 (6) IEC 320-C19 C19: 16A : 20A(16A UL(C-UL) #), ...
Page 19
DELLM0003 @ A$ UL(C-UL), TUV-GS, TUV-S Mark(IRAM), LBC=D(Lo A), GOST, SONCAP, KC, 5(ESV) EMC EN 55022 Class A, CISPR 22 Class A, AS/NZS CISPR 22 Class A, KN 22 Class A, EN 55024, CISPR 24, KN 24, IE...
Page 20
Стойка Dell с функцией измерения потребляемого тока DELLM0003
Page 21
Обзор изделия и спецификации Стойка БРП Dell с функцией измерения потребляемого тока обеспечивает распределение электропитания для оборудования, установленного в стойке. ВЫХОДЫ — в стойке БРП предусмо...
Page 22
DELLM0003 Окружающая среда Максимальная отметка высоты (над СУМ) Нормы безопасности UL(C-UL), TUV-GS, отметка TUV-S (IRAM), Южная Африка (Lo A), ГОСТ, SONCAP, KC, Австралия (ESV) ЭМС EN 55022 Класс A,...
Page 23
Dell (PDU) DELLM0003
Page 24
— PDU (21 ) IEC 320-C13 (6 ) IEC 320-C19 。 DELLM0003 : IEC60309-20 A ;#: IEC60309-16 A 346–415 VAC ± 10% $(%) : 20 A (16 A UL(C-UL) &');#: 16 A 11 k VA 50/60 Hz 200–240 VAC ± 10% ...
Page 25
DELLM0003 $QR (QS8/2) T5 0 V 3,048 m(0 V 10,000 1.) 6U 0 15,240 m(0 V 50,000 1.) W2 T5 0 V 50°C(32 V 122°F) 6U -15 V 60°C(5 V 140°F) X2 9:Z[ UL(C-UL)、TUV-GS、TUV-S Mark (IRAM)、;\ (Lo A)、GOST、SONCAP、...
Page 26
Dell (PDU) DELLM0003
Page 27
Dell PDU 。 — PDU 5 、3、 IEC60309 、520P6S 516P6S。 DELLM0003 : IEC60309-20 A ;": IEC60309-16 A 346–415 VAC ± 10% #$(&) : 20 A (16 A UL(C-UL) ());"...
Page 28
DELLM0003 #RS (R9:0) ?@YZ UL(C-UL)、TUV-GS、TUV-S Mark (IRAM)、A[ (Lo A)、GOST、SONCAP、KC、\0B (ESV) EMC EN 55022 A ]、CISPR 22 A ]、AS/NZS CISPR 22 A ]、 KN 22 A ]、EN 55024、CISPR 24、KN 24、IEC 61000-3-11、IE...