# A B C D E F G H I J K L M N O P Q R S T U V W X Y Z

Danfoss Sound Spectrum for Optyma Slim Pack OP-LSQM084LL Data Sheet

Summary

Engineered for reliable refrigeration cooling, this document provides comprehensive acoustic and sound power spectrum data for the OP-LSQM084LL condensing unit. The manual details performance metrics across various frequency bands (63 Hz to 16 kHz), showing sound pressure levels under standard EN13215 conditions. This technical specification is essential for HVAC engineers, facility managers, and specifiers who require precise noise analysis to ensure optimal system integration and compliance with environmental acoustic standards.

📄 Preview PAGE OF 1

Page 1 Text Content

Acoustic/Sound Spectrum Data (50Hz)

Condensing unit Model OP-LSQM084LL Condensing Unit Code : 114X7092

SO ER EC TR

Housing B3 Compressor : LLZ015T4

Electrical code Number of Fans : 1

Document No 118A1939 Revision : A

Sound Power Spectrum, 1/1 Octave

Model Sound Power Spectrum

16k LWA

OP-LSQM084LL 1/1 Octave d BA

Calculated Sound Pressure (Free Field) (d BA)

Distance (in Meters) 1m 3m 10m Sound Pressure (d B(A))

Acoustic/Sound Spectrum (50Hz)

16k LWA

1/1 OCTAVE FREQUENCY (HZ)

Weighted d BA

Acoustic spectrum data are calculated by addition of sound power levels of compressor and fan motor at full speed according to EN13215 conditions. As compressor and fan motor are placed in a packaged unit, effect of noise reduction due to enclosure and insulation was considered for evaluation of sound power

Subject to change without prior information, Please check Coolselector 2 / Product store for updated information.

Page Summary Contents For Danfoss Sound Spectrum for Optyma Slim Pack OP-LSQM084LL Data Sheet

Page 1 Acoustic/Sound Spectrum Data (50Hz) Condensing unit Model OP-LSQM084LL Condensing Unit Code : 114X7092 SO ER EC TR Housing B3 Compressor : LLZ015T4 Electrical code Number of Fans : 1 Document No 118A1...

Manual Details

Brand Spectrum
Pages 1
File Size 144.75 KB
Published June 05, 2026
10 views

Enter the captcha to get the download link:

captcha

Frequently Asked Questions

What is the maximum calculated sound pressure at 10m distance?

According to the table, the general Sound Pressure (dB(A)) at 10 meters ranges from 44 dB(A) for 63Hz up to 75 dB(A) for 500Hz.

What frequency data is used for calculating sound spectra?

The acoustic spectrum data is calculated by adding the sound power levels of the compressor and fan motor at full speed under EN13215 conditions.

Is the listed sound data considered final or subject to change?

Yes, the manual notes that all information is subject to change without prior notice.