Gain critical insights into the operational acoustics of your condensing unit. This detailed spectrum data provides comprehensive Sound Power Spectrum analysis, measuring noise levels across multiple frequencies (Hz) and distances under EN13215 conditions. The technical documentation details sound pressure calculations derived from the compressor and fan motor performance, allowing HVAC engineers, systems installers, and compliance officers to accurately evaluate ambient noise impact and ensure regulatory adherence for optimal indoor air quality design.

📄 Preview PAGE OF 1

Page 1 Text Content

Acoustic/Sound Spectrum Data (50Hz)

Condensing unit Model OP-MSXM080ML Condensing Unit Code : 114X7204

SO ER EC TR

Housing B3 Compressor : MLZ038T4

Electrical code Number of Fans : 1

Document No 118A1973 Revision : A

Sound Power Spectrum, 1/1 Octave

Model Sound Power Spectrum

16k LWA

OP-MSXM080ML 1/1 Octave d BA

Calculated Sound Pressure (Free Field) (d BA)

Distance (in Meters) 1m 3m 10m Sound Pressure (d B(A))

Acoustic/Sound Spectrum (50Hz)

16k LWA

1/1 OCTAVE FREQUENCY (HZ)

Weighted d BA

Acoustic spectrum data are calculated by addition of sound power levels of compressor and fan motor at full speed according to EN13215 conditions. As compressor and fan motor are placed in a packaged unit, effect of noise reduction due to enclosure and insulation was considered for evaluation of sound power

Subject to change without prior information, Please check Coolselector 2 / Product store for updated information.

Page Summary Contents For Danfoss Sound Spectrum for Optyma Slim Pack OP-MSXM080ML Data Sheet

Page 1 Acoustic/Sound Spectrum Data (50Hz) Condensing unit Model OP-MSXM080ML Condensing Unit Code : 114X7204 SO ER EC TR Housing B3 Compressor : MLZ038T4 Electrical code Number of Fans : 1 Document No 118A1...

Manual Details

Brand Spectrum
Pages 1
File Size 144.75 KB
Published June 04, 2026
13 views

Enter the captcha to get the download link:

captcha

Frequently Asked Questions

What is the specified size model of the condensing unit?

The condensing unit has a model code of OP-MSXM080ML.

How are acoustic spectrum data calculated?

They are calculated by adding the sound power levels of the compressor and fan motor at full speed, following EN13215 conditions.

What is the measured Sound Pressure (dB(A)) at a distance of 10 meters for 63 Hz?

The Sound Pressure for 63 Hz at 10 meters is 44 dB(A).

Does the unit specification account for noise reduction?

Yes, the effect of noise reduction due to enclosure and insulation was considered when evaluating sound power.