Gain detailed acoustic performance data for the OP-LPOM067LL condensing unit. This technical manual provides comprehensive sound power spectrum analysis, mapping noise levels across frequencies from 50Hz to 16kHz at multiple distances (1m, 3m, and 10m). Essential for HVAC engineers, building owners, and specifiers, this resource allows precise evaluation of the packaged unit's operational noise output, ensuring compliance with strict industry acoustic standards.

📄 Preview PAGE OF 1

Page 1 Text Content

Acoustic/Sound Spectrum Data (50Hz)

Condensing unit Model OP-LPOM067LL Condensing Unit Code : 114X3371

SO ER EC TR

Housing H3 Compressor : LLZ013T4

Electrical code Number of Fans : 1

Document No 118A1980 Revision : A

Sound Power Spectrum, 1/1 Octave

Model Sound Power Spectrum

16k LWA

OP-LPOM067LL 1/1 Octave d BA

Calculated Sound Pressure (Free Field) (d BA)

Distance (in Meters) 1m 3m 10m Sound Pressure (d B(A))

Acoustic/Sound Spectrum (50Hz)

16k LWA

1/1 OCTAVE FREQUENCY (HZ)

Weighted d BA

Acoustic spectrum data are calculated by addition of sound power levels of compressor and fan motor at full speed according to EN13215 conditions. As compressor and fan motor are placed in a packaged unit, effect of noise reduction due to enclosure and insulation was considered for evaluation of sound power

Subject to change without prior information, Please check Coolselector 2 / Product store for updated information.

Page Summary Contents For Danfoss Sound Spectrum for Optyma Plus OP-LPOM067LL Data Sheet

Page 1 Acoustic/Sound Spectrum Data (50Hz) Condensing unit Model OP-LPOM067LL Condensing Unit Code : 114X3371 SO ER EC TR Housing H3 Compressor : LLZ013T4 Electrical code Number of Fans : 1 Document No 118A1...

Manual Details

Brand Spectrum
Pages 1
File Size 144.75 KB
Published June 06, 2026
8 views

Enter the captcha to get the download link:

captcha

Frequently Asked Questions

What is the measured sound pressure level at 1 meter?

The sound pressure level at 1 meter is 63 dBA.

At what frequency does the device produce its highest sound power spectrum reading?

The data shows multiple high readings (e.g., 68 to 70) around the 250Hz and 500Hz frequencies.

How is the acoustic spectrum data calculated?

It is calculated by adding the sound power levels of the compressor and fan motor at full speed, following EN13215 conditions.

Are enclosure effects considered in the noise evaluation?

Yes, the effect of noise reduction due to enclosure and insulation was considered for evaluating the sound power.