This technical documentation details the acoustic performance of the OP-MPPM044VV condensing unit. It provides exhaustive sound power and pressure spectra across multiple frequency bands, ensuring users can accurately measure expected noise levels. This manual is essential for HVAC engineers and technicians who need to evaluate the operational sound impact of the packaged compressor and fan motor under realistic, enclosed installation conditions.

📄 Preview PAGE OF 1

Page 1 Text Content

Acoustic/Sound Spectrum Data (90Hz)

Condensing unit Model OP-MPPM044VV Condensing Unit Code : 114X4334

SO ER EC TR

Housing H3 Compressor : VLZ044

Electrical code Number of Fans : 1

Document No 118A2000 Revision : A

Sound Power Spectrum, 1/1 Octave

Model Sound Power Spectrum

16k LWA

OP-MPPM044VV 1/1 Octave d BA

Calculated Sound Pressure (Free Field) (d BA)

Distance (in Meters) 1m 3m 10m Sound Pressure (d B(A))

Acoustic/Sound Spectrum (50Hz)

16k LWA

1/1 OCTAVE FREQUENCY (HZ)

Weighted d BA

Acoustic spectrum data are calculated by addition of sound power levels of compressor and fan motor at full speed according to EN13215 conditions. As compressor and fan motor are placed in a packaged unit, effect of noise reduction due to enclosure and insulation was considered for evaluation of sound power

Subject to change without prior information, Please check Coolselector 2 / Product store for updated information.

Page Summary Contents For Danfoss Sound Spectrum for Optyma INVERTER OP-MPPM044VV Data Sheet

Page 1 Acoustic/Sound Spectrum Data (90Hz) Condensing unit Model OP-MPPM044VV Condensing Unit Code : 114X4334 SO ER EC TR Housing H3 Compressor : VLZ044 Electrical code Number of Fans : 1 Document No 118A200...

Manual Details

Brand Spectrum
Pages 1
File Size 181.57 KB
Published June 06, 2026
8 views

Enter the captcha to get the download link:

captcha

Frequently Asked Questions

What model is covered by this data sheet?

The condensing unit model is OP-MPPM044VV.

How are the sound spectrum data calculated?

They are calculated by adding the sound power levels of the compressor and fan motor at full speed, following EN13215 conditions.

Do these measurements account for noise reduction?

Yes, the effect of noise reduction due to enclosure and insulation was considered during evaluation.

What is the typical sound pressure level at 10 meters (at 90Hz)?

The approximate sound pressure level at 10 meters is 43 dB(A).