# A B C D E F G H I J K L M N O P Q R S T U V W X Y Z

Carrier Omnizone™ Remote Air-Cooled Condenser 09XC 09XC06-24 Omnizone™ Air-Cooled Condensers 5 to 20 Nominal Tons

Summary

The Omnizone™ Air-Cooled Condensers offer high-efficiency, versatile cooling solutions for commercial applications ranging from offices to factories. Designed for flexible indoor remote installation, these units provide superior performance and durability in challenging climates. This technical guide provides comprehensive information on selection procedures, electrical data, mounting specifications, and performance optimization, making it essential reading for HVAC engineers and facility managers requiring reliable, high-capacity cooling systems with minimal routine service.

📄 Preview 📖 Table of Contents Contents PAGE OF 20

Page 1 Text Content

Product Data Omnizone™ Air-Cooled Condensers 5 to 20 Nominal Tons

09XC06-24 Indoor Remote Air-cooled Condenser Units,  Vertical Installation with Rear Return Air  and Horizontal Air Discharge

© 2023 Carrier Form 09XC-6PD

Page Summary Contents For Carrier Omnizone™ Remote Air-Cooled Condenser 09XC 09XC06-24 Omnizone™ Air-Cooled Condensers 5 to 20 Nominal Tons

Page 1 Product Data Omnizone™ Air-Cooled Condensers 5 to 20 Nominal Tons 09XC06-24 Indoor Remote Air-cooled Condenser Units,  Vertical Installation with Rear Return Air  and Horizontal Air Discharge © 2023...
Page 2 Features/Benefits The Omnizone 09XC air- Application flexibility Special features for out- cooled condenser units The unit can be placed where no other standing performance provide a practical and opt...
Page 3 Model number nomenclature 09XC AA Factory-Installed Options Code 09XC – Omnizone™ Remote Air-Cooled Condenser Reserved for future add-ons Unit Size – Nominal Tons Design Revision Level 0 – Original Re...
Page 4 Factory-installed options ITEM FACTORY-INSTALLED OPTION FIELD-INSTALLED ACCESSORY Low Ambient Operation Factory-installed options fan speed to control head pressure. This fan speed control permits uni...
Page 5 Dimensions — 09XC06-24 SIZE 16, 24 SIZE 06-14 LIQUID CONDENSER COND INLET CONDENSER OUTLET UNIT WIDTH HEIGHT DEPTH LIQUID OUTLET DISCHARGE DUCT COND RETURN DUCT DIAMETER INLET DIAMETER 09XC (BLOWER OP...
Page 6 Dimensions (cont) Unit Clearances 24 (TYP) NOTE: Dimensions are in inches. Selection procedure Condenser Usage Use Carrier’s performance and selection software to UNIT 09XC CONDENSER QUANTITY perform ...
Page 7 Performance data Condenser Fan Performance — 09XC06 Unitsa,b,c,d,e ESP (in. wg) cfm 0.00 0.10 0.20 0.30 0.40 0.50 0.60 0.70 0.80 0.90 rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rp...
Page 8 Performance data (cont) Condenser Fan Performance — 09XC08 Unitsa,b,c,d,e ESP (in. wg) cfm 0.00 0.10 0.20 0.30 0.40 0.50 0.60 0.70 rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp ESP (...
Page 9 Performance data (cont) Condenser Fan Performance — 09XC12 Unitsa,b,c,d,e ESP (in. wg) cfm 0.00 0.10 0.20 0.30 0.40 0.50 0.60 0.70 rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp ESP (...
Page 10 Performance data (cont) Condenser Fan Performance — 09XC14 Unitsa,b,c,d,e ESP (in. wg) cfm 0.00 0.10 0.20 0.30 0.40 0.50 0.60 0.70 rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp ESP (...
Page 11 Performance data (cont) Condenser Fan Performance — 09XC16 Unitsa,b,c,d,e ESP (in. wg) cfm 0.00 0.10 0.20 0.30 0.40 0.50 0.60 0.70 0.80 0.90 rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm...
Page 12 Performance data (cont) Condenser Fan Performance — 09XC24 Unitsa,b,c,d,e ESP (in. wg) cfm 0.00 0.10 0.20 0.30 0.40 0.50 0.60 0.70 rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp rpm bhp ESP (...
Page 13 Electrical data Fan Electrical Data VOLTAGE MOTOR HP V-PH-Hz RANGE FLA MCA MOPD DISC Min Max LEGEND 2. Wire sizing amps are a sum of 125% of the compressor RLA plus 100% of indoor fan motor FLA. FLA F...
Page 14 Controls Operating sequence break control power to the OFC and the fan will stop. If a safety control in the unit opens, the 09XC condenser fan The 09XC condensing unit may be used with different will...
Page 15 Typical piping and wiring 09XC Unit Matched with 50XCR Indoor Unit CONTROL WIRING TO 50XCR INDOOR UNIT POWER WIRING (TO FIELD-SUPPLIED DISCONNECT PER NEC) DISCHARGE LINE CIRCUIT 1 PIPING TO 50XCR INDO...
Page 16 Application data Location For best results unit must be properly located and installed. Suspended Unit on Inside Wall Locate condenser where an adequate supply of inlet out- STEEL door air is availabl...
Page 17 Application data (cont) Liquid lift and subcooler circuit Liquid lines Amount of liquid lift available before refrigerant flashing 1. Liquid line can generally be sized for a 1° to 2°F occurs depends ...
Page 18 Application data (cont) System with Evaporator Above Condenser System with Condenser Above Evaporator TRAP (MUST BE ABOVE TOP OF CONDENSER COIL) SLOPE 50XCR UNIT TOWARD REMOTE CONDENSER CONDENSING UNI...
Page 19 Guide specifications Remote Air-Cooled Condenser Unit C. Fans: 1. Fans shall be double inlet, centrifugal wheel HVAC Guide Specifications with forward-curved blades, designed for contin- Size Range: 5...
Page 20 Carrier Corporation • Syracuse, New York 13221 3-23 Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations. P...

Manual Details

Brand Carrier
Pages 20
File Size 1.46 MB
Published June 05, 2026
51 views

Enter the captcha to get the download link:

captcha

Frequently Asked Questions

How does this unit handle limited space or odd building placements?

Its small footprint and high static capability allow it to be placed in tight spaces where other solutions may fail.

What type of electrical power is required for operation?

The unit operates on three-phase electric power, with a dedicated low voltage 24-v control system.

What temperature range can it operate within?

It maintains performance at ambient temperatures ranging from 55 to 115°F.

Is the unit built to withstand corrosive outdoor environments?

Yes, the weatherproof cabinets are designed to endure harsh conditions and pass a 500-Hour Salt Spray Test.