Page 1
Integrated Dell Remote Access Controller 8 (i DRAC8) with Lifecycle Controller for Dell Power Edge Servers Version 2.30.119.30 Release Notes
Page 2
Release Notes Integrated Dell Remote Access Controller (i DRAC) i DRAC is a systems management hardware and software solution that provides remote management capabilities, crashed system recovery, and...
Page 3
Supported Managed Server Operating Systems for i DRAC8 The following operating systems are supported by i DRAC8: • Windows Server 2008 R2 SP1 Foundation Edition • Windows Server 2008 R2 SP1 Enterprise...
Page 4
What’s New • Added support for the Intel E5-26xx v4 family of processors. • Added support for Redfish 1.0, which a standard for data center and systems management that delivers improved performance, f...
Page 5
• If the instant messenger is launched in the Virtual Console viewer with Active X native plug-in and another application is started (example Notepad, Word Pad, and so on) without minimizing the Virtu...
Page 6
• The default time zone value is US Central Time. To make sure Single Sign-On (SSO) and Directory Service TFA (smart card) continue to work properly, the i DRAC time zone must match the time zone wher...
Page 7
Issue 2: Description If the management station is using Linux operating system with the Pass all keystrokes to server option enabled, you cannot resize the Virtual Console viewer window by dragging th...
Page 8
Versions/Systems Affected All Dell Power Edge systems with i DRAC8 and out-of-band enabled PERC storage controllers. Issue 7: Description When enclosures connected in the redundant path are re-wired (...
Page 9
Issue 11: Description In some scenarios, typically when a PCIe SSD is removed from a server slot and a different PCIe SSD is inserted quickly (that is, within 5-10 seconds) into the same slot, the ser...
Page 10
Issue 15: Description In the Network Interfaces page > Host OS Network Interfaces section, the link to the Network Devices page is not available for embedded LOM. Resolution In the Network Devices ...
Page 11
Versions/Systems Affected All Dell Power Edge systems with i DRAC8. Issue 20: Description If the PERC controllers have global hot spare assigned and a virtual disk is deleted, the physical disk config...
Page 12
Resolution Use a user name and password without reserved characters and then perform an update. Versions/Systems Affected All Dell Power Edge systems with i DRAC8. Issue 25: Description On the Dell 13...
Page 13
Issue 29: Description In the i DRAC web interface, the following storage pending operations status is not displayed in Pending Operations pop-up message and Storage->Pending Operations page: • Virt...
Page 14
Versions/ Systems Affected All Dell Power Edge systems with i DRAC8. Issue 34: Description Sometimes Virtual Console does not get enabled after i DRAC is reset. Resolution Toggle the Virtual Console o...
Page 15
Versions/ Systems Affected All Dell Power Edge systems with i DRAC8. Issue 39: Description When the physical drives connected to a PERC storage controller are in Non-RAID (or unitialized) state, the s...
Page 16
Resolution After setting the password with racadm, ensure that you enable the user using either racadm or i DRAC GUI. You can also set the plain text password in the GUI by selecting the Change Passwo...
Page 17
Issue 48: Description While enumerating using WS-MAN, if you include more than 7 properties in the WQL/CQL query, the select query does not return any result. Resolution The maximum number of properti...
Page 18
Issue 53: Description On the Dell 12th generation Power Edge systems, when downgrading from 2.10.10 to 1.66.65, existing users may occasionally be lost. Resolution Re-enter the users after the downgra...
Page 19
Issue 58: Description SNMP Agent Default Community Name (public). [Nessus] Resolution i DRAC provides limited read-only information to third-party tools for identification purposes only. The SNMP Agen...
Page 20
Version/Systems Affected All Dell Power Edge systems with i DRAC8. Issue 236311: Description Persistence policy is not supported on Chassis Slot NIC devices. Resolution Reconfigure or clear the Virtua...
Page 21
Issue 171960: Description Lifecycle Controller firmware is inaccessible after a performing hardware diagnostic and rebooting the system. This issue is captured in the Lifecycle Controller log. Resolut...
Page 22
Versions/ Systems Affected All Dell Power Edge systems with USB 3.0 enabled in BIOS and running Windows Server 2008 R2 operating system on the host server. Issue 210079: Description While creating vir...
Page 23
Issue 233773: Description After applying the Boot Identity profile on the Power Edge M630 blade server with DX69G NDC card on port 1, the WWN/MAC page displays the MAC Addresses under the Flexaddress ...
Page 24
i DRAC - Limitations • If floppy emulation is enabled when a bootable USB key is mounted as a Virtual Media from the Virtual Console and if you try to delete any file from the mounted USB key (floppy)...
Page 25
• USB NIC IP address must always be assigned Link Local address. Assigning IP address other than Link Local IP address or conflicting IP address of other network interface may cause network related is...
Page 26
• Fibre channel NIC cards with dual or four ports are displayed as a single port card in Lifecycle Controller. However, all ports are updated when a firmware update is performed. • The option to enabl...
Page 27
Resolution To distinguish between the port numbers, see the MAC address or the Device Settings. You can access Device Settings in the following methods: • During POST, press <F2>, and then click...
Page 28
Issue 9: Description The process of retrieving IPv6 address from the DHCP server with VLAN connection takes a few minutes. Resolution Wait for a few minutes and check the Network Settings page to view...
Page 29
• Network operations such as Update, Export, or Import may take more time than expected. The delay may occur because the source or destination share is not reachable or does not exist, or due to other...
Page 30
LC-RS - Limitations • The drivers exposed by Lifecycle Controller are present in a read-only device labeled OEMDRV, and the device is active for 18 hours. In a Microsoft(r) Windows(r) and Linux enviro...
Page 31
• Collect System Inventory On Reboot (CSIOR) must to be run before enum is successful. • BCM57xx /BCM57xxx updates Limitations - When you update the firmware on Broadcom Net Xterme I and QLogic BCM57x...
Page 32
7. Select the firmware file and click Install or Install and Reboot. If it is a DUP, Install dynamically changes to Install and Reboot and at the same time the Install Next Reboot is activated. When y...
Page 33
Sample Open WSMAN CLI Command (Enumeration Operation): wsman enumerate http://schemas.dmtf.org/wbem/wscim/1/cim-schema/2/DCIM_System View -h (idrac ip adddress) -P 443 -u (idrac user) -p (idrac passwo...
Page 34
Information in this document is subject to change without notice. © 2016 Dell Inc. All rights reserved. Reproduction of these materials in any manner whatsoever without the written permission of Dell ...