This essential guide provides technical IT professionals and system administrators with comprehensive instructions for installing the Dell EMC NetWorker Module for Microsoft. The module integrates enterprise backup capabilities with complex Microsoft environments, including Windows Server Core, Exchange, and SharePoint. This manual details all prerequisites, advanced configuration checks, specific version requirements, and critical troubleshooting steps needed to ensure seamless, reliable data protection across your enterprise infrastructure.

📄 Preview 📖 Table of Contents Contents PAGE OF 30

Page 1 Text Content

Dell EMC Net Worker Module for Microsoft Installation Guide 19.3

Dell Inc.

June 2020 Rev. 01

Page Summary Contents For Dell NetWorker Module for Microsoft 19.3 Installation Guide

Page 1 Dell EMC Net Worker Module for Microsoft Installation Guide 19.3 Dell Inc. June 2020 Rev. 01
Page 2 Notes, cautions, and warnings NOTE: A NOTE indicates important information that helps you make better use of your product. CAUTION: A CAUTION indicates either potential damage to hardware or loss of d...
Page 3 Contents List of Figures..........................................................................................................................................................5 List of Tables.........
Page 4 4 Configuration Tasks....................................................................................................................27 Configuring a dedicated storage node for NMM...................
Page 5 List of Figures Figure 1. NMM Exchange Admin Configuration tool.........................................................................................14 Figure 2. NMM Installation Options page.........
Page 6 List of Tables Table 1. Revision history......................................................................................................................................... Table 2. Style convent...
Page 7 Preface As part of an effort to improve product lines, periodic revisions of software and hardware are released. Therefore, all versions of the software or hardware currently in use might not support ...
Page 8 Typographical conventions The following type style conventions are used in this document: Table 2. Style conventions Bold Used for interface elements that a user specifically selects or clicks, for ex...
Page 9 2. On the Support tab, click Contact Support. 3. On the Contact Information page, click the relevant support, and then proceed. Service requests To obtain in-depth help from Licensing, submit a servic...
Page 10 Introduction Topics: Overview Requirements Exchange Server-specific configuration requirements Prerequisites to perform GLR by using Item Point for Microsoft Share Point Server Overview The Net Worker...
Page 11 NOTE: The Net Worker E-LAB Navigator at https://elabnavigator.emc.com/eln/elnhome contains the most up-to-date information about NMM compatibility. Requirement to restore NMM 8.2.x or earlier backups ...
Page 12 Table 3. NMM support matrix for Net Worker server versions(continued) Net Worker server version NMM 19.3 Net Worker server 9.0.1 Yes Net Worker server 9.0 Yes Net Worker server 8.2 SP3 and SP4 Yes Net...
Page 13 Hyper-V proxy node in a single proxy environment: 1 Gb/s LAN connection to DD, or a minimum 100 MB/s transfer rate 1 GHz CPU (single core) 512 MB RAM Hyper-V proxy node in a multi-proxy environment: S...
Page 14 Exchange Server-specific configuration requirements Complete certain configuration tasks before you install the Net Worker client and the NMM software for Exchange Server backup and recovery. The Net ...
Page 15 Table 5. Exchange Server GLR MAPI/CDO requirements(continued) Exchange Server version Required MAPI/CDO version Exchange Server 2013 MAPI/CDO 1.2.1 version 6.5.8353.0 or later Exchange Server 2016 Not...
Page 16 Installing the Item Point Agent for Content Transfer Service Steps 1. Log in to the Share Point Server using Administrative privileges. 2. Run the Agent for Content Transfer Service installation wizar...
Page 17 Configuration Checks and Installation Topics: Accessing the installation files Running preconfiguration checks and installing the software Installing NMM in MSCS and MSFCS environments Installing NMM ...
Page 18 To run the System Configuration Checker before the NMM installation process, select Run System Configuration Checker, and then click Next. Application Host is selected automatically. The System Config...
Page 19 Figure 2. NMM Installation Options page If you are upgrading from a previous NMM release, select Restore of NMM 8.2.x and Earlier Backups (VSS workflows). For example, select this option if you are up...
Page 20 The GLR Options page appears. The NMM installer selects a default path for the Mount Point Location and Hyper-V VHD Mount Point Location. To change the mount point location: a. Click (...). b. Select ...
Page 21 Installing NMM on Windows Server Core When you install NMM on Windows 2012, 2012 R2, or 2016 Server Core, the installation process installs the NMM GUI. However, it is not recommended to use the NMM G...
Page 22 From the Microsoft Windows menus: a. Select Start > Settings > Control Panel > Programs > Programs and Features. b. Select Net Worker Module for Microsoft. c. Click Change. 3. In the Welco...
Page 23 Net Worker Updating from a Previous Release Guide and the nsrpush man page describe how to use Client Push to update Net Worker products. Upgrading NMM from a previous release About this task You cann...
Page 24 Next steps After you install NMM, perform a full backup of the Exchange Server or SQL Server data. You cannot use NMM to recover data from a backup that was performed by using NME. You can use NMM to ...
Page 25 Silent Installation Topics: Install NMM silently Remove NMM silently Upgrade NMM silently Silently modifying the NMM installation Install NMM silently Silent (unattended) installation is a stand-alone...
Page 26 Table 6. NMM installer variables Variable Valid values Default value Enable SSMS [0|1] Enable SSMSBackup Tab [0|1] Enable SSMSScript [0|1] Config Firewall [0|1] Install Level [100|150] Not applicable ...
Page 27 Configuration Tasks Topics: Configuring a dedicated storage node for NMM Configuring a Direct File Access folder for GLR Configuring NMM Proxy Recovery Agent for Hyper-V FLR Events notifications and e...
Page 28 Configuring NMM Proxy Recovery Agent for Hyper-V FLR For NMM Hyper-V File Level Recovery (FLR) web UI configurations, configure an NMM Proxy Recovery Agent (RA). You can use NMM Proxy RA to perform re...
Page 29 Removing directives after migrating to NMM After you migrate to NMM from other modules such as NME and NMSQL, remove any directives on the application servers that skip database files during a file sy...
Page 30 deleted resource id 8.0.72.7.0.0.0.0.174.29.184.76.0.0.0.0.10.5.220.27(1) nsradmin> Inconsistent VSS writer state after Net Worker client installation After Net Worker client installation, some VSS...

Manual Details

Brand Microsoft
Pages 30
File Size 257.29 KB
Published June 06, 2026
50 views

Enter the captcha to get the download link:

captcha

Frequently Asked Questions

What are the prerequisites for restoring NMM 8.2.x or earlier backups?

Check the dedicated section in the manual for specific requirements. General prerequisites include checking supported Microsoft .NET Framework versions and server/client NetWorker versions.

How do I fix an issue with a cached public key on the NetWorker server's local hosts resource?

To correct this, delete the NSR Peer Information on the backup server using the command: nsradmin -p nsrexec -s bv-rcserver

The VSS writers are showing inconsistent states after installation; what should I do?

Restart the client host. Once restarted, observe that the VSS writers return to a consistent state, and then retry the backup.

Can the system reboot during NMM setup if .NET Framework 4.0 is pre-installed?

Yes, the system may automatically reboot if a granular recovery option is selected while .NET Framework 4.0 is already installed. Follow Microsoft documentation for reduction guidance and rerun the installer after reboot.