# A B C D E F G H I J K L M N O P Q R S T U V W X Y Z

Dell Lifecycle Controller 2 Version 1.00.00 Remote Services Readme

Summary

Readme documentation for Integrated Dell Remote Access Controller 7 (iDRAC7) version 1.00.00 and Lifecycle Controller 2 Remote Services (LC2-RS). The document details supported Dell PowerEdge systems (M620, R620, R720, R720xd, T620), managed server operating systems including Windows Server 2008/2012, Red Hat Enterprise Linux, SUSE Linux, VMware ESX, and Hyper-V. It covers licensing requirements, firmware update procedures, known issues, and WS-Management protocol-based remote provisioning capabilities. Targeted at enterprise system administrators managing Dell server infrastructure through remote out-of-band management interfaces.

📄 Preview 📖 Table of Contents Contents PAGE OF 20

Page 1 Text Content

Integrated Dell Remote Access Controller 7 (i DRAC7) Version 1.00.00 and Lifecycle Controller 2 Remote Services (LC2-RS) Version 1.00.00

Readme

Page Summary Contents For Dell Lifecycle Controller 2 Version 1.00.00 Remote Services Readme

Page 1 Integrated Dell Remote Access Controller 7 (i DRAC7) Version 1.00.00 and Lifecycle Controller 2 Remote Services (LC2-RS) Version 1.00.00 Readme
Page 3 This readme contains information for both i DRAC7 and LC2-RS. i DRAC7 is a systems management hardware and software solution that provides remote management capabilities, crashed system recovery, and ...
Page 4 Supported Web Browsers for i DRAC7  Microsoft Internet Explorer 7.0 for Windows Server 2003 SP2, Windows Server 2008 SP2, Windows XP 32-bit SP3, and Windows Vista(R) SP2  Microsoft Internet Explorer...
Page 5 Upgrade i DRAC7 firmware cannot be installed on platforms that support i DRAC6 and cannot be used to upgrade i DRAC6 firmware to i DRAC7. Uninstallation Use the rollback feature to return to the previ...
Page 6 Sample Win RM Command (Enumeration Operation): winrm e cimv2/DCIM_System View?__cimnamespace=root/dcim -u:[idrac user] -p:[idrac password] -r:https://[idrac ip adddress]/wsman -encoding:utf-8 -a:basic...
Page 7  For i DRAC7 Enterprise, when the Virtual Console is disabled and Virtual Media is disabled and/or detached, the console port (default: 5900) remains open. For i DRAC7 Express (no Virtual Console or ...
Page 8  If invalid credentials are used for the maximum login attempts, the IP is blocked for the duration of the IP Blocking Penalty Time and a message is not displayed.  If Internet Explorer (IE) 64-bit ...
Page 9  Firefox versions 4.x, 6.x, and 7.x may prevent the i DRAC7 Web interface from opening when using IPv6. For more information see: https://bugzilla.mozilla.org/show_bug.cgi?id=633001  On Microsoft Wi...
Page 10 Issue 5 Description If you are using Linux management station, you may have problems moving or resizing the Virtual Console when Pass all keystrokes to server is enabled. This is a limitation of X-Win...
Page 11 Issue 8 Description When enclosures connected in the redundant path are re-wired (connections are switched) to result in a non-redundant path, the reported connected port value of the enclosures may n...
Page 12 Issue 11 Description On Microsoft Windows7 operating system, while launching Virtual Console in native mode using Internet Explorer, the i DRAC7 Login page is displayed. Virtual Console uses plug-ins ...
Page 13 Issue 14 Description When Enterprise or Enterprise Evaluation license expires, Active Directory is disabled automatically. Resolution After re-installing the Enterprise or Enterprise Evaluation licens...
Page 14 Issue 17 Description When a driver pack DUP update is performed, the following message is recorded in the Lifecycle log after the driver pack update entry. RAC0400: i DRAC memory low i DRAC is running...
Page 15 Issue 20 Description In the i DRAC7 Web interface > Overview > Server > Power/Thermal > Power Monitoring tab > Power section, the Power Unit selector only changes the unit of measure. D...
Page 16 Issue 24 Description After performing storage operations on PERC through Option-ROM (CTRL-R) or before a system reset (warm boot), the corresponding events are not recorded in Lifecycle log. SNMP trap...
Page 17 Issue 27 Description When launching Virtual Console viewer using Active X plugin, sometimes a blank window appears and Virtual Console viewer may not launch. Resolution This may be due to incompatible...
Page 18  System Characterization must be enabled to correctly run the firmware update during system power on after a Power Supply Unit (PSU) replacement. If System Characterization is not enabled, the firmwa...
Page 19 Issue 4 Description When two PSUs of same wattage and make are replaced and Part Replacement (Allow Version Upgrade only or Match firmware of replacement part option) feature is enabled, during platfo...
Page 20 Global Support For information on technical support, visit www.dell.com/contactus. For information on documentation support, visit support.dell.com/manuals. On the Manuals page, click Software ‐>Sy...

Manual Details

Brand Dell
Pages 20
File Size 476.66 KB
Published June 27, 2026
8 views

Enter the captcha to get the download link:

captcha

Frequently Asked Questions

What prerequisites must be met before updating iDRAC7 firmware?

You must install appropriate IPMI and managed node drivers, enable the WMI service if using Windows, and disconnect any Virtual Media.

Are there still physical hardware licensing requirements for LC2-RS?

No; software licensing has replaced hardware licensing. You must install correct licenses, as features like Auto Discovery are now licensed.

What operating system support is provided by iDRAC7?

iDRAC7 supports various OS environments including Windows Server 2008 R2 and SUSE Linux Enterprise Server (SLES) 10 SP4.

If the firmware update process for iDRAC7 fails, what procedure should I follow?

If the iDRAC7 firmware update is interrupted for any reason, you must wait for at least 30 minutes before attempting to start it again.